Aberration-free three-dimensional multiphoton imaging of neuronal activity at kHz rates
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Multiphoton microscopy is a powerful tool in neuroscience, promising to deliver important data on the spatiotemporal activity within individual neurons as well as in networks of neurons. A major limitation of current technologies is the relatively slow scan rates along the z direction compared to the kHz rates obtainable in the x and y directions. Here, we describe a custom-built microscope system based on an architecture that allows kHz scan rates over hundreds of microns in all three dimensions without introducing aberration. We further demonstrate how this high-speed 3D multiphoton imaging system can be used to study neuronal activity at millisecond resolution at the subcellular as well as the population level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Cited by
Structural and molecular interrogation of intact biological systems
Chung, K., Wallace, J., Kim, S.-Y., Kalyanasundaram, S., Andalman, A. S., Davidson, T. J., Mirzabekov, J. J., Zalocusky, K. A., Mattis, J., Denisin, A. K., et al. (2013) · Nature · doi:10.1038/nature12107 · Cited by 2,008
“(8) Now that the whole chamber is filled with FocusClear, use PDMS sealant (Kwik-Sil) across both vertical openings between the putty, dish and slide to fully seal the chamber and prevent evaporation.”
A large field of view two-photon mesoscope with subcellular resolution for in vivo imaging
Sofroniew, N. J., Flickinger, D., King, J., & Svoboda, K. (2016) · eLife · doi:10.7554/elife.14472 · Cited by 645
Advances in multiphoton microscopy technology
Hoover, E. E., & Squier, J. A. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.361 · Cited by 542
In vivo imaging of neural activity
Yang, W., & Yuste, R. (2017) · Nature Methods · doi:10.1038/nmeth.4230 · Cited by 406
Rapid 3D light-sheet microscopy with a tunable lens
Fahrbach, F. O., Voigt, F. F., Schmid, B., Helmchen, F., & Huisken, J. (2013) · Optics Express · doi:10.1364/oe.21.021010 · Cited by 347
Technologies for imaging neural activity in large volumes
Ji, N., Freeman, J., & Smith, S. L. (2016) · Nature Neuroscience · doi:10.1038/nn.4358 · Cited by 278
Deconvolution-free Subcellular Imaging with Axially Swept Light Sheet Microscopy
Dean, K. M., Roudot, P., Welf, E. S., Danuser, G., & Fiolka, R. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.05.013 · Cited by 253
High-speed volumetric imaging of neuronal activity in freely moving rodents
Skocek, O., Nöbauer, T., Weilguny, L., Martínez Traub, F., Xia, C. N., Molodtsov, M. I., Grama, A., Yamagata, M., Aharoni, D., Cox, D. D., et al. (2018) · Nature Methods · doi:10.1038/s41592-018-0008-0 · Cited by 206
Sapoznik, E., Chang, B.-J., Huh, J., Ju, R. J., Azarova, E. V., Pohlkamp, T., Welf, E. S., Broadbent, D., Carisey, A. F., Stehbens, S. J., et al. (2020) · eLife · doi:10.7554/elife.57681 · Cited by 196
“In OPM, the fluorescence captured by the primary objective is relayed in an aberration-free remote focusing (Botcherby et al., 2012) format to a secondary objective, which creates a 3D replica of the fluorescent signal at its focus that is then imaged by a tilted tertiary objective onto a camera…”
dal Maschio, M., Donovan, J. C., Helmbrecht, T. O., & Baier, H. (2017) · Neuron · doi:10.1016/j.neuron.2017.04.034 · Cited by 169
Light-sheet microscopy of cleared tissues with isotropic, subcellular resolution
Chakraborty, T., Driscoll, M. K., Jeffery, E., Murphy, M. M., Roudot, P., Chang, B.-J., Vora, S., Wong, W. M., Nielson, C. D., Zhang, H., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0615-4 · Cited by 183
Fluorescence imaging of large-scale neural ensemble dynamics
Kim, T. H., & Schnitzer, M. J. (2022) · Cell · doi:10.1016/j.cell.2021.12.007 · Cited by 159
“, 2015), enable rapid steering of the illumination beam in three dimensions (Botcherby et al., 2012; Grewe et al., 2011; Kong et al., 2015), and increase data acquisition rates by multiplexing different illumination beams in time and/or space (Cheng et al.”
Background
Metadata
- Authors
- Botcherby, E. J., Smith, C. W., Kohl, M. M., Débarre, D., Booth, M. J., Juškaitis, R., Paulsen, O., & Wilson, T.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-02-06
- Volume
- 109
- Issue
- 8
- Pages
- 2919-2924
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2147549961
- Cited by
- 187
- References
- 2
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.