Near-infrared fluorescent sensor for in vivo copper imaging in a murine Wilson disease model
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
Copper is an essential metal nutrient that is tightly regulated in the body because loss of its homeostasis is connected to severe diseases such as Menkes and Wilson diseases, Alzheimer’s disease, prion disorders, and amyotrophic lateral sclerosis. The complex relationships between copper status and various stages of health and disease remain challenging to elucidate, in part due to a lack of methods for monitoring dynamic changes in copper pools in whole living organisms. Here we present the synthesis, spectroscopy, and in vivo imaging applications of Coppersensor 790, a first-generation fluorescent sensor for visualizing labile copper pools in living animals. Coppersensor 790 combines a near-infrared emitting cyanine dye with a sulfur-rich receptor to provide a selective and sensitive turn-on response to copper. This probe is capable of monitoring fluctuations in exchangeable copper stores in living cells and mice under basal conditions, as well as in situations of copper overload or deficiency. Moreover, we demonstrate the utility of this unique chemical tool to detect aberrant increases in labile copper levels in a murine model of Wilson disease, a genetic disorder that is characterized by accumulation of excess copper. The ability to monitor real-time copper fluxes in living animals offers potentially rich opportunities to examine copper physiology in health and disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Critical Stability Constants: First Supplement
Martell, A. E., & Smith, R. M. (1982) · Springer eBooks · doi:10.1007/978-1-4615-6761-5 · Cited by 6,008
Neurodegenerative diseases and oxidative stress
Barnham, K. J., Masters, C. L., & Bush, A. I. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1330 · Cited by 3,683
In vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653 · cited 1×
“This fluorophore platform possesses near-IR absorption and emission profiles to maximize tissue penetration of the fluorescent signal from the dye while minimizing native tissue autofluorescence, in addition to being biologically inert, nontoxic, and compatible with aqueous media (42, 43).”
BackgroundMetals in Neurobiology: Probing Their Chemistry and Biology with Molecular Imaging
Que, E. L., Domaille, D. W., & Chang, C. J. (2008) · Chemical Reviews · doi:10.1021/cr078203u · Cited by 2,061
Self-citationShedding light onto live molecular targets
Weissleder, R., & Ntziachristos, V. (2003) · Nature Medicine · doi:10.1038/nm0103-123 · Cited by 1,909 · cited 1×
“This fluorophore platform possesses near-IR absorption and emission profiles to maximize tissue penetration of the fluorescent signal from the dye while minimizing native tissue autofluorescence, in addition to being biologically inert, nontoxic, and compatible with aqueous media (42, 43).”
BackgroundGaggelli, E., Kozlowski, H., Valensin, D., & Valensin, G. (2006) · Chemical Reviews · doi:10.1021/cr040410w · Cited by 1,729
Principles of bioinorganic chemistry
(1995) · Choice Reviews Online · doi:10.5860/choice.32-4515 · Cited by 1,534
A non-disruptive technique for loading calcium buffers and indicators into cells
Tsien, R. Y. (1981) · Nature · doi:10.1038/290527a0 · Cited by 1,131 · cited 1×
“1), which, unlike CS790, is able to accumulate within cells (52, 53) (Fig.”
BackgroundSynthetic fluorescent sensors for studying the cell biology of metals
Domaille, D. W., Que, E. L., & Chang, C. J. (2008) · Nature Chemical Biology · doi:10.1038/nchembio.69 · Cited by 1,081
Self-citationThe common biology of cancer and ageing
Finkel, T., Serrano, M., & Blasco, M. A. (2007) · Nature · doi:10.1038/nature05985 · Cited by 988 · cited 1×
“Indeed, loss of copper homeostasis in the body has severe consequences owing to its potent redox activity, which, if uncontrolled, can lead to aberrant oxidative and nitrosative stress events that accompany diseases ranging from cancer (8) to cardiovascular disorders (9–11) to Alzheimer’s and related neurodegenerative…”
Background
Cited by
Fluorescent Sensors for Measuring Metal Ions in Living Systems
Carter, K. P., Young, A. M., & Palmer, A. E. (2014) · Chemical Reviews · doi:10.1021/cr400546e · Cited by 2,451
Yuan, L., Lin, W., Zheng, K., He, L., & Huang, W. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35313j · Cited by 1,822
Recent progress in the development of near-infrared fluorescent probes for bioimaging applications
Guo, Z., Park, S., Yoon, J., & Shin, I. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60271k · Cited by 1,801
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Connecting copper and cancer: from transition metal signalling to metalloplasia
Ge, E. J., Bush, A. I., Casini, A., Cobine, P. A., Cross, J. R., DeNicola, G. M., Dou, Q. P., Franz, K. J., Gohil, V. M., Gupta, S., et al. (2022) · Nature Reviews Cancer · doi:10.1038/s41568-021-00417-2 · Cited by 1,298
Self-citationRecent Development of Chemosensors Based on Cyanine Platforms
Sun, W., Guo, S., Hu, C., Fan, J., & Peng, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00001 · Cited by 1,109
Metal coordination in photoluminescent sensing
Liu, Z., He, W., & Guo, Z. (2013) · Chemical Society Reviews · doi:10.1039/c2cs35363f · Cited by 800
Yu, F., Li, P., Wang, B., & Han, K. (2013) · Journal of the American Chemical Society · doi:10.1021/ja401360a · Cited by 621
Synthetic fluorescent probes for studying copper in biological systems
Cotruvo, Jr., Aron, A. T., Ramos-Torres, K. M., & Chang, C. J. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00346b · Cited by 558
Self-citationA DNAzyme-Gold Nanoparticle Probe for Uranyl Ion in Living Cells
Wu, P., Hwang, K., Lan, T., & Lu, Y. (2013) · Journal of the American Chemical Society · doi:10.1021/ja400150v · Cited by 428
Chemically diverse small molecule fluorescent chemosensors for copper ion
Sivaraman, G., Iniya, M., Anand, T., Kotla, N. G., Sunnapu, O., Singaravadivel, S., Gulyani, A., & Chellappa, D. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.11.020 · Cited by 391
Wu, D., Chen, L., Lee, W., Ko, G., Yin, J., & Yoon, J. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.06.011 · Cited by 335
Chen, H., Dong, B., Tang, Y., & Lin, W. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00087 · Cited by 322
Aron, A. T., Ramos-Torres, K. M., Cotruvo, J. A., & Chang, C. J. (2015) · Accounts of Chemical Research · doi:10.1021/acs.accounts.5b00221 · Cited by 280
Self-citationYang, Z., Loh, K. Y., Chu, Y.-T., Feng, R., Satyavolu, N. S. R., Xiong, M., Nakamata Huynh, S. M., Hwang, K., Li, L., Xing, H., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b09867 · Cited by 252
Chemical Design of Activatable Photoacoustic Probes for Precise Biomedical Applications
Liu, Y., Teng, L., Yin, B., Meng, H., Yin, X., Huan, S., Song, G., & Zhang, X.-B. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00875 · Cited by 245
Cheng, G., Fan, J., Sun, W., Cao, J., Hu, C., & Peng, X. (2014) · Chem. Commun. · doi:10.1039/c3cc47864e · Cited by 218
“Donor–Two-Acceptor” Dye Design: A Distinct Gateway to NIR Fluorescence
Karton-Lifshin, N., Albertazzi, L., Bendikov, M., Baran, P. S., & Shabat, D. (2012) · Journal of the American Chemical Society · doi:10.1021/ja308124q · Cited by 216
Copper signaling in the mammalian nervous system: Synaptic effects
Gaier, E. D., Eipper, B. A., & Mains, R. E. (2013) · Journal of Neuroscience Research · doi:10.1002/jnr.23143 · Cited by 209
“, 2011) and in vivo, demonstrating increased circulating Cu(1) paired with decreased liver Cu(1) in ATP7B mice (Hirayama et al., 2012).”
A Highly Selective Ratiometric Two-Photon Fluorescent Probe for Human Cytochrome P450 1A
Dai, Z.-R., Ge, G.-B., Feng, L., Ning, J., Hu, L.-H., Jin, Q., Wang, D.-D., Lv, X., Dou, T.-Y., Cui, J.-N., et al. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b09854 · Cited by 194
Ackerman, C. M., Lee, S., & Chang, C. J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04631 · Cited by 177
Self-citationLee, S., Barin, G., Ackerman, C. M., Muchenditsi, A., Xu, J., Reimer, J. A., Lutsenko, S., Long, J. R., & Chang, C. J. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b02515 · Cited by 176
Self-citationCopper regulates rest-activity cycles through the locus coeruleus-norepinephrine system
Xiao, T., Ackerman, C. M., Carroll, E. C., Jia, S., Hoagland, A., Chan, J., Thai, B., Liu, C. S., Isacoff, E. Y., & Chang, C. J. (2018) · Nature Chemical Biology · doi:10.1038/s41589-018-0062-z · Cited by 167
“As a starting point for our investigations, we sought to visualize distributions of labile copper within the brains of these living organisms, as previous in vivo copper imaging studies were limited primarily to liver detection 31,32 .”
Self-citationChung, C. Y.-S., Posimo, J. M., Lee, S., Tsang, T., Davis, J. M., Brady, D. C., & Chang, C. J. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1904610116 · Cited by 159
Self-citationGrover, K., Koblova, A., Pezacki, A. T., Chang, C. J., & New, E. J. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00819 · Cited by 129
Self-citation
Metadata
- Authors
- Hirayama, T., Van de Bittner, G. C., Gray, L. W., Lutsenko, S., & Chang, C. J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-01-30
- Volume
- 109
- Issue
- 7
- Pages
- 2228-2233
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1995151567
- Cited by
- 220
- References
- 62
- FWCI
- 9.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.