Direct magnetic resonance detection of myelin and prospects for quantitative imaging of myelin density
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Magnetic resonance imaging has previously demonstrated its potential for indirectly mapping myelin density, either by relaxometric detection of myelin water or magnetization transfer. Here, we investigated whether myelin can be detected and possibly quantified directly. We identified the spectrum of myelin in the spinal cord in situ as well as in myelin lipids extracted via a sucrose gradient method, and investigated its spectral properties. High-resolution solution NMR spectroscopy showed the extract composition to be in agreement with myelin’s known chemical make-up. The 400-MHz 1 H spectrum of the myelin extract, at 20 °C (room temperature) and 37 °C, consists of a narrow water resonance superimposed on a broad envelope shifted ∼3.5 ppm upfield, suggestive of long-chain methylene protons. Superimposed on this signal are narrow components resulting from functional groups matching the chemical shifts of the constituents making up myelin lipids. The spectrum could be modeled as a sum of super-Lorentzians with a T 2 * distribution covering a wide range of values (0.008–26 ms). Overall, there was a high degree of similarity between the spectral properties of extracted myelin lipids and those found in neural tissue. The normalized difference spectrum had the hallmarks of membrane proteins, not present in the myelin extract. Using 3D radially ramp-sampled proton MRI, with a combination of adiabatic inversion and echo subtraction, the feasibility of direct myelin imaging in situ is demonstrated. Last, the integrated signal from myelin suspensions is shown, both spectroscopically and by imaging, to scale with concentration, suggesting the potential for quantitative determination of myelin density.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo visualization of myelin water in brain by magnetic resonance
Mackay, A., Whittall, K., Adler, J., Li, D., Paty, D., & Graeb, D. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310614 · Cited by 914 · cited 1×
“Spectral components with T2 values ranging from 10 to 50 ms have been assigned to motionally restricted myelin water (12, 13) and have demonstrated strong correlation with myelin-specific histologic staining (12, 14).”
BackgroundMagnetization transfer ratio and myelin in postmortem multiple sclerosis brain
Schmierer, K., Scaravilli, F., Altmann, D. R., Barker, G. J., & Miller, D. H. (2004) · Annals of Neurology · doi:10.1002/ana.20202 · Cited by 776 · cited 1×
“For example, MT is sensitive not only to myelin content but also to axon density (15).”
BackgroundAccelerating the Nonuniform Fast Fourier Transform
Greengard, L., & Lee, J.-Y. (2004) · SIAM Review · doi:10.1137/s003614450343200x · Cited by 727 · cited 1×
“gridding algorithm (39) and incorporating k-space trajectory correction (40).”
BackgroundMagnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging
Robson, M. D., Gatehouse, P. D., Bydder, M., & Bydder, G. M. (2003) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200311000-00001 · Cited by 717 · cited 1×
“Typical implementations include either 3D radial sampling with nonselective rf pulses (19) or 2D radial sampling with sliceselective half rf pulses and ramp sampling (20) as previously applied for the characterization of cortical bone matrix and bone water (21, 22).”
MethodDousset, V, Grossman, R. I., Ramer, K. N., Schnall, M. D., Young, L. H., Gonzalez-Scarano, F., Lavi, E., & Cohen, J. A. (1992) · Radiology · doi:10.1148/radiology.182.2.1732968 · Cited by 690 · cited 2×
“In MT, cross-relaxation between myelin protons and tissue water is exploited (9).”
BackgroundQuantitative interpretation of NMR relaxation data
Whittall, K. P., & MacKay, A. L. (1989) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(89)90011-5 · Cited by 628 · cited 1×
“T2 relaxometry yields T2 spectra, typically by inversion of the Carr-Purcell echo decay using an inverse Laplace transformation (11).”
MethodMyelin water imaging in multiple sclerosis: quantitative correlations with histopathology
Laule, C., Leung, E., Li, D. K., Traboulsee, A. L., Paty, D. W., MacKay, A. L., & Moore, G. R. (2006) · Multiple Sclerosis Journal · doi:10.1177/1352458506070928 · Cited by 489 · cited 6×
“S3 Inset also shows a very broad envelope more akin to motionally constrained membrane proteins, such as PLP andMBP (see, e.g., refs 5 and 6).”
BackgroundMethodInfluentialMagnetic Resonance of Myelin, Myelination, and Myelin Disorders
Valk, J., & van der Knaap, M. S. (1989) · Springer eBooks · doi:10.1007/978-3-662-02568-0 · Cited by 404
Myelin water imaging of multiple sclerosis at 7 T: Correlations with histopathology
Laule, C., Kozlowski, P., Leung, E., Li, D. K. B., MacKay, A. L., & Moore, G. R. W. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.12.008 · Cited by 379 · cited 1×
“Spectral components with T2 values ranging from 10 to 50 ms have been assigned to motionally restricted myelin water (12, 13) and have demonstrated strong correlation with myelin-specific histologic staining (12, 14).”
BackgroundSpiking and nonspiking classes of oligodendrocyte precursor glia in CNS white matter
Káradóttir, R., Hamilton, N. B., Bakiri, Y., & Attwell, D. (2008) · Nature Neuroscience · doi:10.1038/nn2060 · Cited by 370
THE LIPID COMPOSITION OF PURIFIED BOVINE BRAIN MYELIN*
NORTON, W. T., & AUTILIO, L. A. (1966) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1966.tb06794.x · Cited by 354 · cited 2×
“S2B) NMR, showing good agreement with previously determined molar ratios (25) (Table 1).”
ResultCoherent Anti-Stokes Raman Scattering Imaging of Axonal Myelin in Live Spinal Tissues
Wang, H., Fu, Y., Zickmund, P., Shi, R., & Cheng, J.-X. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.061911 · Cited by 316 · cited 1×
“X-ray diffraction (4) and nonlinear optical techniques (5, 6) also provide insight into myelin ultrastructure.”
BackgroundCross relaxation and spin diffusion in the proton NMR of hydrated collagen
Edzes, H. T., & Samulski, E. T. (1977) · Nature · doi:10.1038/265521a0 · Cited by 310 · cited 1×
“Another potential problem could arise from saturation of the myelin signal via cross-relaxation (35).”
BackgroundHigh field MRI correlates of myelin content and axonal density in multiple sclerosis
Mottershead, J. P., Schmierer, K., Clemence, M., Thornton, J. S., Scaravilli, F., Barker, G. J., Tofts, P. S., Newcombe, J., Cuzner, M. L., Ordidge, R. J., et al. (2003) · Journal of Neurology · doi:10.1007/s00415-003-0192-3 · Cited by 296 · cited 2×
“The signal attenuation resulting from off-resonance saturation (MT ratio) has been found to scale with myelin concentration (10).”
BackgroundMethodApparent diffusion tensor measurements in myelin-deficient rat spinal cords
Gulani, V., Webb, A. G., Duncan, I. D., & Lauterbur, P. C. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200102)45:2<191::aid-mrm1025>3.0.co;2-9 · Cited by 251 · cited 1×
“Spectral components with T2 values ranging from 10 to 50 ms have been assigned to motionally restricted myelin water (12, 13) and have demonstrated strong correlation with myelin-specific histologic staining (12, 14).”
BackgroundMembrane partitioning: Distinguishing bilayer effects from the hydrophobic effect
Wimley, W. C., & White, S. H. (1993) · Biochemistry · doi:10.1021/bi00076a001 · Cited by 231 · cited 1×
“In this enthalpy-driven process (29) the myelin lipid suspension regains a structural order reminiscent of physiological myelin minus the protein component.”
BackgroundFu, Y., Huff, T. B., Wang, H.-W., Cheng, J.-X., & Wang, H. (2008) · Optics Express · doi:10.1364/oe.16.019396 · Cited by 169 · cited 1×
“X-ray diffraction (4) and nonlinear optical techniques (5, 6) also provide insight into myelin ultrastructure.”
BackgroundImaging of CNS myelin by positron-emission tomography
Stankoff, B., Wang, Y., Bottlaender, M., Aigrot, M., Dollé, F., Wu, C., Feinstein, D. L., Huang, G.-F., Semah, F., Mathis, C. A., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0600769103 · Cited by 169 · cited 2×
“Such agents are currently under development for both MRI (7) and positron-emission tomography (8).”
BackgroundMethodProton nuclear magnetic resonance lineshapes in lamellar liquid crystals
Wennerström, H. (1973) · Chemical Physics Letters · doi:10.1016/0009-2614(73)80333-1 · Cited by 125 · cited 5×
“Ulmius J, Wennerström H, Lindblom G, Arvidson G (1975) Proton NMR bandshape studies of lamellar liquid crystals and gel phases containing lecithins and cholesterol.”
BackgroundMethodInfluentialOrigins of the ultrashort‐T21H NMR signals in myelinated nerve: A direct measure of myelin content?
Horch, R. A., Gore, J. C., & Does, M. D. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22980 · Cited by 121 · cited 2×
“performed multiexponential fitting of the time-domain signal decay (18).”
Background[46] Isolation of myelin from nerve tissue
Norton, W. T. (1974) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/0076-6879(74)31049-x · Cited by 114
Techawiboonwong, A., Song, H. K., & Wehrli, F. W. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1179 · Cited by 114 · cited 1×
“Typical implementations include either 3D radial sampling with nonselective rf pulses (19) or 2D radial sampling with sliceselective half rf pulses and ramp sampling (20) as previously applied for the characterization of cortical bone matrix and bone water (21, 22).”
MethodSelf-citationMRI of the brain with ultra-short echo-time pulse sequences
Waldman, A. D., Rees, J. H., Brock, C., Robson, M. D., Gatehouse, P. D., & Bydder, G. M. (2003) · Neuroradiology · doi:10.1007/s00234-003-1076-z · Cited by 109 · cited 3×
“, <1 ms) signal from human brain in vivo (23).”
BackgroundInfluentialMultinuclear solid-state three-dimensional MRI of bone and synthetic calcium phosphates
Wu, Y., Chesler, D. A., Glimcher, M. J., Garrido, L., Wang, J., Jiang, H. J., & Ackerman, J. L. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.4.1574 · Cited by 98 · cited 1×
“Typical implementations include either 3D radial sampling with nonselective rf pulses (19) or 2D radial sampling with sliceselective half rf pulses and ramp sampling (20) as previously applied for the characterization of cortical bone matrix and bone water (21, 22).”
MethodDesign of practical T2‐selective RF excitation (TELEX) pulses
Sussman, M. S., Pauly, J. M., & Wright, G. A. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400615 · Cited by 92 · cited 1×
“, selective half-sinc pulses of 400- to 600-μs duration (34)], all but the longest T2* components of the myelin protons would elude detection.”
BackgroundTHE CHEMICAL COMPOSITION OF BOVINE CNS MYELIN*
Norton, W. T., & Autilio, L. A. (1965) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1965.tb20193.x · Cited by 88 · cited 1×
“SC) (26), inherent variability of the measurement (27), and the developmentally immature nature of the tissue examined (26).”
BackgroundGruber, S., Mlynárik, V., & Moser, E. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10377 · Cited by 65 · cited 1×
“Given a reported resolution for MRSI of 5–10 mm (37), we project the resolution achievable with our method to be roughly on the order of 2.”
MethodComplete proton magnetic resonance in whole cells
Bloom, M., Holmes, K. T., Mountford, C. E., & Williams, P. G. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90219-2 · Cited by 56 · cited 2×
“The myelin resonance is consistent with the SL lineshape of a dipolar-broadened liquid–crystalline lipid system (24, 30) as suggested by several lineshape properties (31), including a small second moment (M2 = 1.”
BackgroundMethodStructure and Stability of Internodal Myelin in Mouse Models of Hereditary Neuropathy
Avila, R. L., Inouye, H., Baek, R. C., Yin, X., Trapp, B. D., Feltri, M. L., Wrabetz, L., & Kirschner, D. A. (2005) · Journal of Neuropathology and Experimental Neurology · doi:10.1097/01.jnen.0000186925.95957.dc · Cited by 54 · cited 3×
“We first assume that 80% of the wet weight of neural tissue comes from water (4).”
BackgroundWu, Y., Hrovat, M. I., Ackerman, J. L., Reese, T. G., Cao, H., Ecklund, K., & Glimcher, M. J. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22130 · Cited by 54 · cited 1×
“, who imaged the collagen matrix of cortical bone (36).”
BackgroundA Myelin-Specific Contrast Agent for Magnetic Resonance Imaging of Myelination
Frullano, L., Wang, C., Miller, R. H., & Wang, Y. (2011) · Journal of the American Chemical Society · doi:10.1021/ja1040896 · Cited by 37 · cited 18×
“Last, our analysis suggests that translation from the laboratory to clinical MRI will be challenging.”
BackgroundInfluentialA comparison of the chemical analyses of cell lipids with their complete proton NMR spectrum
Holmes, K. T., Williams, P. G., King, N. J. C., May, G. L., Dyne, M., Bloom, M. J., & Mountford, C. E. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910040607 · Cited by 26
(2005) · Springer eBooks · doi:10.1007/3-540-27660-2_1 · Cited by 17
Cited by
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Magnetic Resonance of Myelin Water: An in vivo Marker for Myelin
MacKay, A. L., & Laule, C. (2016) · Brain Plasticity · doi:10.3233/bpl-160033 · Cited by 284
So You Want to Image Myelin Using MRI: An Overview and Practical Guide for Myelin Water Imaging
Lee, J., Hyun, J., Lee, J., Choi, E., Shin, H., Min, K., Nam, Y., Kim, H. J., & Oh, S. (2021) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27059 · Cited by 134
Promise and pitfalls of g-ratio estimation with MRI
Campbell, J. S. W., Leppert, I. R., Narayanan, S., Boudreau, M., Duval, T., Cohen-Adad, J., Pike, G. B., & Stikov, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.038 · Cited by 129
Formalin tissue fixation biases myelin – sensitive MRI
Seifert, A. C., Umphlett, M., Hefti, M., Fowkes, M., & Xu, J. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27821 · Cited by 44
Metadata
- Authors
- Wilhelm, M. J., Ong, H. H., Wehrli, S. L., Li, C., Tsai, P.-H., Hackney, D. B., & Wehrli, F. W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-05-24
- Volume
- 109
- Issue
- 24
- Pages
- 9605-9610
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2015128894
- Cited by
- 168
- References
- 33
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.