Direct magnetic resonance detection of myelin and prospects for quantitative imaging of myelin density
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Magnetic resonance imaging has previously demonstrated its potential for indirectly mapping myelin density, either by relaxometric detection of myelin water or magnetization transfer. Here, we investigated whether myelin can be detected and possibly quantified directly. We identified the spectrum of myelin in the spinal cord in situ as well as in myelin lipids extracted via a sucrose gradient method, and investigated its spectral properties. High-resolution solution NMR spectroscopy showed the extract composition to be in agreement with myelin’s known chemical make-up. The 400-MHz 1 H spectrum of the myelin extract, at 20 °C (room temperature) and 37 °C, consists of a narrow water resonance superimposed on a broad envelope shifted ∼3.5 ppm upfield, suggestive of long-chain methylene protons. Superimposed on this signal are narrow components resulting from functional groups matching the chemical shifts of the constituents making up myelin lipids. The spectrum could be modeled as a sum of super-Lorentzians with a T 2 * distribution covering a wide range of values (0.008–26 ms). Overall, there was a high degree of similarity between the spectral properties of extracted myelin lipids and those found in neural tissue. The normalized difference spectrum had the hallmarks of membrane proteins, not present in the myelin extract. Using 3D radially ramp-sampled proton MRI, with a combination of adiabatic inversion and echo subtraction, the feasibility of direct myelin imaging in situ is demonstrated. Last, the integrated signal from myelin suspensions is shown, both spectroscopically and by imaging, to scale with concentration, suggesting the potential for quantitative determination of myelin density.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo visualization of myelin water in brain by magnetic resonance
Mackay, A., Whittall, K., Adler, J., Li, D., Paty, D., & Graeb, D. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310614 · Cited by 914 · cited 1×
“Spectral components with T2 values ranging from 10 to 50 ms have been assigned to motionally restricted myelin water (12, 13) and have demonstrated strong correlation with myelin-specific histologic staining (12, 14).”
BackgroundMagnetization transfer ratio and myelin in postmortem multiple sclerosis brain
Schmierer, K., Scaravilli, F., Altmann, D. R., Barker, G. J., & Miller, D. H. (2004) · Annals of Neurology · doi:10.1002/ana.20202 · Cited by 776 · cited 1×
“For example, MT is sensitive not only to myelin content but also to axon density (15).”
BackgroundAccelerating the Nonuniform Fast Fourier Transform
Greengard, L., & Lee, J.-Y. (2004) · SIAM Review · doi:10.1137/s003614450343200x · Cited by 727 · cited 1×
“gridding algorithm (39) and incorporating k-space trajectory correction (40).”
BackgroundMagnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging
Robson, M. D., Gatehouse, P. D., Bydder, M., & Bydder, G. M. (2003) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200311000-00001 · Cited by 717 · cited 1×
“Typical implementations include either 3D radial sampling with nonselective rf pulses (19) or 2D radial sampling with sliceselective half rf pulses and ramp sampling (20) as previously applied for the characterization of cortical bone matrix and bone water (21, 22).”
MethodDousset, V, Grossman, R. I., Ramer, K. N., Schnall, M. D., Young, L. H., Gonzalez-Scarano, F., Lavi, E., & Cohen, J. A. (1992) · Radiology · doi:10.1148/radiology.182.2.1732968 · Cited by 690 · cited 2×
“In MT, cross-relaxation between myelin protons and tissue water is exploited (9).”
BackgroundQuantitative interpretation of NMR relaxation data
Whittall, K. P., & MacKay, A. L. (1989) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(89)90011-5 · Cited by 628 · cited 1×
“T2 relaxometry yields T2 spectra, typically by inversion of the Carr-Purcell echo decay using an inverse Laplace transformation (11).”
MethodMyelin water imaging in multiple sclerosis: quantitative correlations with histopathology
Laule, C., Leung, E., Li, D. K., Traboulsee, A. L., Paty, D. W., MacKay, A. L., & Moore, G. R. (2006) · Multiple Sclerosis Journal · doi:10.1177/1352458506070928 · Cited by 489 · cited 6×
“S3 Inset also shows a very broad envelope more akin to motionally constrained membrane proteins, such as PLP andMBP (see, e.g., refs 5 and 6).”
BackgroundMethodInfluentialMagnetic Resonance of Myelin, Myelination, and Myelin Disorders
Valk, J., & van der Knaap, M. S. (1989) · Springer eBooks · doi:10.1007/978-3-662-02568-0 · Cited by 404
Myelin water imaging of multiple sclerosis at 7 T: Correlations with histopathology
Laule, C., Kozlowski, P., Leung, E., Li, D. K. B., MacKay, A. L., & Moore, G. R. W. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.12.008 · Cited by 379 · cited 1×
“Spectral components with T2 values ranging from 10 to 50 ms have been assigned to motionally restricted myelin water (12, 13) and have demonstrated strong correlation with myelin-specific histologic staining (12, 14).”
BackgroundSpiking and nonspiking classes of oligodendrocyte precursor glia in CNS white matter
Káradóttir, R., Hamilton, N. B., Bakiri, Y., & Attwell, D. (2008) · Nature Neuroscience · doi:10.1038/nn2060 · Cited by 370
Cited by
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Magnetic Resonance of Myelin Water: An in vivo Marker for Myelin
MacKay, A. L., & Laule, C. (2016) · Brain Plasticity · doi:10.3233/bpl-160033 · Cited by 284
So You Want to Image Myelin Using MRI: An Overview and Practical Guide for Myelin Water Imaging
Lee, J., Hyun, J., Lee, J., Choi, E., Shin, H., Min, K., Nam, Y., Kim, H. J., & Oh, S. (2021) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27059 · Cited by 134
Promise and pitfalls of g-ratio estimation with MRI
Campbell, J. S. W., Leppert, I. R., Narayanan, S., Boudreau, M., Duval, T., Cohen-Adad, J., Pike, G. B., & Stikov, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.038 · Cited by 129
Formalin tissue fixation biases myelin – sensitive MRI
Seifert, A. C., Umphlett, M., Hefti, M., Fowkes, M., & Xu, J. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27821 · Cited by 44
Ercan, E., Varma, G., Mädler, B., Dimitrov, I. E., Pinho, M. C., Xi, Y., Wagner, B. C., Davenport, E. M., Maldjian, J. A., Alsop, D. C., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27211 · Cited by 40
“This contribution is also supported by the known dipolar-broadening of the macromolecular line(13) taken together with the recent reports of the substantial lipid contribution to the myelin line shape.(14,15) To fully understand the origins of the ihMT contrast in human brain, further research is necessary.”
BackgroundDusek, P., Madai, V. I., Huelnhagen, T., Bahn, E., Matej, R., Sobesky, J., Niendorf, T., Acosta‐Cabronero, J., & Wuerfel, J. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27595 · Cited by 22
Metadata
- Authors
- Wilhelm, M. J., Ong, H. H., Wehrli, S. L., Li, C., Tsai, P.-H., Hackney, D. B., & Wehrli, F. W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-05-24
- Volume
- 109
- Issue
- 24
- Pages
- 9605-9610
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2015128894
- Cited by
- 168
- References
- 33
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.