Optically monitoring voltage in neurons by photo-induced electron transfer through molecular wires
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Fluorescence imaging is an attractive method for monitoring neuronal activity. A key challenge for optically monitoring voltage is development of sensors that can give large and fast responses to changes in transmembrane potential. We now present fluorescent sensors that detect voltage changes in neurons by modulation of photo-induced electron transfer (PeT) from an electron donor through a synthetic molecular wire to a fluorophore. These dyes give bigger responses to voltage than electrochromic dyes, yet have much faster kinetics and much less added capacitance than existing sensors based on hydrophobic anions or voltage-sensitive ion channels. These features enable single-trial detection of synaptic and action potentials in cultured hippocampal neurons and intact leech ganglia. Voltage-dependent PeT should be amenable to much further optimization, but the existing probes are already valuable indicators of neuronal activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new generation of Ca2+ indicators with greatly improved fluorescence properties.
Grynkiewicz, G., Poenie, M., & Tsien, R. Y. (1985) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)83641-4 · Cited by 21,607
Self-citationFluorescent indicators for Ca2+based on green fluorescent proteins and calmodulin
Miyawaki, A., Llopis, J., Heim, R., McCaffery, J. M., Adams, J. A., Ikura, M., & Tsien, R. Y. (1997) · Nature · doi:10.1038/42264 · Cited by 3,248
Self-citationImaging neural activity in worms, flies and mice with improved GCaMP calcium indicators
Tian, L., Hires, S. A., Mao, T., Huber, D., Chiappe, M. E., Chalasani, S. H., Petreanu, L., Akerboom, J., McKinney, S. A., Schreiter, E. R., et al. (2009) · Nature Methods · doi:10.1038/nmeth.1398 · Cited by 1,967
Fluorescent indicators for cytosolic calcium based on rhodamine and fluorescein chromophores
Minta, A., Kao, J. P. Y., & Tsien, R. Y. (1989) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)83165-9 · Cited by 1,613
Self-citationCircularly permuted green fluorescent proteins engineered to sense Ca 2+
Nagai, T., Sawano, A., Park, E. S., & Miyawaki, A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.051636098 · Cited by 966
Bilayer Thickness and Membrane Protein Function: An Energetic Perspective
Andersen, O. S., & Koeppe, R. E. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132643 · Cited by 866
Molecular-wire behaviour in p -phenylenevinylene oligomers
Davis, W. B., Svec, W. A., Ratner, M. A., & Wasielewski, M. R. (1998) · Nature · doi:10.1038/23912 · Cited by 711
Tsien, R. Y., Rink, T. J., & Poenie, M. (1985) · Cell Calcium · doi:10.1016/0143-4160(85)90041-7 · Cited by 656
Self-citationChanges of free calcium levels with stages of the cell division cycle
Poenie, M., Alderton, J., Tsien, R. Y., & Steinhardt, R. A. (1985) · Nature · doi:10.1038/315147a0 · Cited by 591
Self-citationCa2+ Indicators Based on Computationally Redesigned Calmodulin-Peptide Pairs
Palmer, A. E., Giacomello, M., Kortemme, T., Hires, S. A., Lev-Ram, V., Baker, D., & Tsien, R. Y. (2006) · Chemistry & Biology · doi:10.1016/j.chembiol.2006.03.007 · Cited by 508
Self-citation
Cited by
All-optical electrophysiology in mammalian neurons using engineered microbial rhodopsins
Hochbaum, D. R., Zhao, Y., Farhi, S. L., Klapoetke, N., Werley, C. A., Kapoor, V., Zou, P., Kralj, J. M., Maclaurin, D., Smedemark-Margulies, N., et al. (2014) · Nature Methods · doi:10.1038/nmeth.3000 · Cited by 770
From the neuron doctrine to neural networks
Yuste, R. (2015) · Nature Reviews Neuroscience · doi:10.1038/nrn3962 · Cited by 754
Development and plasticity of the primary visual cortex
Espinosa, J. S., & Stryker, M. P. (2012) · Neuron · doi:10.1016/j.neuron.2012.06.009 · Cited by 672
Current developments in fluorescent PET (photoinduced electron transfer) sensors and switches
Daly, B., Ling, J., & de Silva, A. P. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00334a · Cited by 627
Bright Building Blocks for Chemical Biology
Lavis, L. D., & Raines, R. T. (2014) · ACS Chemical Biology · doi:10.1021/cb500078u · Cited by 536
Design and Application of Fluorescent Probes to Detect Cellular Physical Microenvironments
Ma, J., Sun, R., Xia, K., Xia, Q., Liu, Y., & Zhang, X. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00573 · Cited by 408
Small-molecule fluorophores and fluorescent probes for bioimaging
Terai, T., & Nagano, T. (2013) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-013-1234-z · Cited by 301
Activity‐Based Sensing: A Synthetic Methods Approach for Selective Molecular Imaging and Beyond
Bruemmer, K. J., Crossley, S. W. M., & Chang, C. J. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201909690 · Cited by 265
Teaching Old Dyes New Tricks: Biological Probes Built from Fluoresceins and Rhodamines
Lavis, L. D. (2017) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-061516-044839 · Cited by 260
Rational design of small molecule fluorescent probes for biological applications
Jun, J. V., Chenoweth, D. M., & Petersson, E. J. (2020) · Organic & Biomolecular Chemistry · doi:10.1039/d0ob01131b · Cited by 254
A Photostable Silicon Rhodamine Platform for Optical Voltage Sensing
Huang, Y.-L., Walker, A. S., & Miller, E. W. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b06644 · Cited by 222
Self-citationPalette of fluorinated voltage-sensitive hemicyanine dyes
Yan, P., Acker, C. D., Zhou, W.-L., Lee, P., Bollensdorff, C., Negrean, A., Lotti, J., Sacconi, L., Antic, S. D., Kohl, P., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1214850109 · Cited by 170
Farsi, Z., Preobraschenski, J., van den Bogaart, G., Riedel, D., Jahn, R., & Woehler, A. (2016) · Science · doi:10.1126/science.aad8142 · Cited by 96
“Cl (11) to quantitatively measure ∆ψ across the”
Nag, O. K., Stewart, M. H., Deschamps, J. R., Susumu, K., Oh, E., Tsytsarev, V., Tang, Q., Efros, A. L., Vaxenburg, R., Black, B. J., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b00954 · Cited by 80
“that require complicated synthesis and purification schemes.(75,85,94,95) Third, the QD quenching”
McKeithan, W. L., Feyen, D. A. M., Bruyneel, A. A. N., Okolotowicz, K. J., Ryan, D. A., Sampson, K. J., Potet, F., Savchenko, A., Gómez-Galeno, J., Vu, M., et al. (2020) · Cell stem cell · doi:10.1016/j.stem.2020.08.003 · Cited by 50
“Cl (Miller et al., 2012) loading solution was prepared as described in McKeithan et al.”
Method
Metadata
- Authors
- Miller, E. W., Lin, J. Y., Frady, E. P., Steinbach, P. A., Kristan, W. B., & Tsien, R. Y.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-01-24
- Volume
- 109
- Issue
- 6
- Pages
- 2114-2119
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2059149310
- Cited by
- 323
- References
- 40
- FWCI
- 11.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.