Functional single-cell hybridoma screening using droplet-based microfluidics
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Monoclonal antibodies can specifically bind or even inhibit drug targets and have hence become the fastest growing class of human therapeutics. Although they can be screened for binding affinities at very high throughput using systems such as phage display, screening for functional properties (e.g., the inhibition of a drug target) is much more challenging. Typically these screens require the generation of immortalized hybridoma cells, as well as clonal expansion in microtiter plates over several weeks, and the number of clones that can be assayed is typically no more than a few thousand. We present here a microfluidic platform allowing the functional screening of up to 300,000 individual hybridoma cell clones within less than a day. This approach should also be applicable to nonimmortalized primary B-cells, as no cell proliferation is required: Individual cells are encapsulated into aqueous microdroplets and assayed directly for the release of antibodies inhibiting a drug target based on fluorescence. We used this system to perform a model screen for antibodies that inhibit angiotensin converting enzyme 1, a target for hypertension and congestive heart failure drugs. When cells expressing these antibodies were spiked into an unrelated hybridoma cell population in a ratio of 1∶10,000 we observed a 9,400-fold enrichment after fluorescence activated droplet sorting. A wide variance in antibody expression levels at the single-cell level within a single hybridoma line was observed and high expressors could be successfully sorted and recultivated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Corti, D., Voss, J., Gamblin, S. J., Codoni, G., Macagno, A., Jarrossay, D., Vachieri, S. G., Pinna, D., Minola, A., Vanzetta, F., et al. (2011) · Science · doi:10.1126/science.1205669 · Cited by 1,203 · cited 1×
“Just recently, a method for the selection of primary B-cells releasing antibodies binding influenza virus hemagglutinin A has been developed in a microtiter plate format and even enabled the identification of a neutralizing antibody (24).”
MethodMicrodroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Development trends for human monoclonal antibody therapeutics
Nelson, A. L., Dhimolea, E., & Reichert, J. M. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd3229 · Cited by 1,026
Selecting and screening recombinant antibody libraries
Hoogenboom, H. R. (2005) · Nature Biotechnology · doi:10.1038/nbt1126 · Cited by 973
Baret, J.-C., Miller, O. J., Taly, V., Ryckelynck, M., El-Harrak, A., Frenz, L., Rick, C., Samuels, M. L., Hutchison, J. B., Agresti, J. J., et al. (2009) · Lab on a Chip · doi:10.1039/b902504a · Cited by 951
Self-citationBiopharmaceutical benchmarks 2010
Walsh, G. (2010) · Nature Biotechnology · doi:10.1038/nbt0910-917 · Cited by 756
Clausell-Tormos, J., Lieber, D., Baret, J.-C., El-Harrak, A., Miller, O. J., Frenz, L., Blouwolff, J., Humphry, K. J., Köster, S., Duan, H., et al. (2008) · Chemistry & Biology · doi:10.1016/j.chembiol.2008.04.004 · Cited by 720
Self-citationDrop-based microfluidic devices for encapsulation of single cells
Köster, S., Angilè, F. E., Duan, H., Agresti, J. J., Wintner, A., Schmitz, C., Rowat, A. C., Merten, C. A., Pisignano, D., Griffiths, A. D., et al. (2008) · Lab on a Chip · doi:10.1039/b802941e · Cited by 518
Self-citationControlled encapsulation of single-cells into monodisperse picolitre drops
Edd, J. F., Di Carlo, D., Humphry, K. J., Köster, S., Irimia, D., Weitz, D. A., & Toner, M. (2008) · Lab on a Chip · doi:10.1039/b805456h · Cited by 511
Drugs targeting the renin–angiotensin–aldosterone system
Zaman, M. A., Oparil, S., & Calhoun, D. A. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd873 · Cited by 439
Pillar-induced droplet merging in microfluidic circuits
Niu, X., Gulati, S., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b813325e · Cited by 374
Microfluidic high-throughput encapsulation and hydrodynamic self-sorting of single cells
Chabert, M., & Viovy, J.-L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708321105 · Cited by 344
Wei, L., Clauser, E., Alhenc-Gelas, F., & Corvol, P. (1992) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)42224-7 · Cited by 256
Beating Poisson encapsulation statistics using close-packed ordering
Abate, A. R., Chen, C.-H., Agresti, J. J., & Weitz, D. A. (2009) · Lab on a Chip · doi:10.1039/b909386a · Cited by 189
Screening individual hybridomas by microengraving to discover monoclonal antibodies
Ogunniyi, A. O., Story, C. M., Papa, E., Guillen, E., & Love, J. C. (2009) · Nature Protocols · doi:10.1038/nprot.2009.40 · Cited by 164
Memory B Cell Antibodies to HIV-1 gp140 Cloned from Individuals Infected with Clade A and B Viruses
Mouquet, H., Klein, F., Scheid, J. F., Warncke, M., Pietzsch, J., Oliveira, T. Y. K., Velinzon, K., Seaman, M. S., & Nussenzweig, M. C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0024078 · Cited by 111
High throughput production of mouse monoclonal antibodies using antigen microarrays
Masi, F. D., Chiarella, P., Wilhelm, H., Massimi, M., Bullard, B., Ansorge, W. J., & Sawyer, A. M. (2005) · PROTEOMICS · doi:10.1002/pmic.200401279 · Cited by 76
Parvathy, S., Oppong, S. Y., Karran, E. H., Buckle, D. R., Turner, A. J., & Hooper, N. M. (1997) · Biochemical Journal · doi:10.1042/bj3270037 · Cited by 55
Karsunke, X. Y. Z., Pschenitza, M., Rieger, M. M., Weber, E., Nießner, R., & Knopp, D. (2011) · Journal of Immunological Methods · doi:10.1016/j.jim.2011.06.016 · Cited by 23
Introduction A: Recent Advances in Cytometry Instrumentation, Probes, and Methods
Pierzchalski, A., Mittag, A., & Tárnok, A. (2011) · Methods in cell biology · doi:10.1016/b978-0-12-374912-3.00001-8 · Cited by 21
Remy, M. H., Frobert, Y., & Grassi, J. (1995) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1995.0651d.x · Cited by 20
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Self-citationCao, Y., Su, B., Guo, X., Sun, W., Deng, Y., Bao, L., Zhu, Q., Zhang, X., Zheng, Y., Geng, C., et al. (2020) · Cell · doi:10.1016/j.cell.2020.05.025 · Cited by 1,188
Single-cell barcoding and sequencing using droplet microfluidics
Zilionis, R., Nainys, J., Veres, A., Savova, V., Zemmour, D., Klein, A. M., & Mazutis, L. (2017) · Nature Protocols · doi:10.1038/nprot.2016.154 · Cited by 727
Shembekar, N., Chaipan, C., Utharala, R., & Merten, C. A. (2016) · Lab on a Chip · doi:10.1039/c6lc00249h · Cited by 372
Self-citation
Metadata
- Authors
- Debs, B. E., Utharala, R., Balyasnikova, I. V., Griffiths, A. D., & Merten, C. A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-07-02
- Volume
- 109
- Issue
- 29
- Pages
- 11570-11575
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2062857909
- Cited by
- 276
- References
- 21
- FWCI
- 11.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.