The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
On-chip manipulation of single microparticles, cells, and organisms using surface acoustic waves
Open accessAbstract
Techniques that can dexterously manipulate single particles, cells, and organisms are invaluable for many applications in biology, chemistry, engineering, and physics. Here, we demonstrate standing surface acoustic wave based “acoustic tweezers” that can trap and manipulate single microparticles, cells, and entire organisms (i.e., Caenorhabditis elegans ) in a single-layer microfluidic chip. Our acoustic tweezers utilize the wide resonance band of chirped interdigital transducers to achieve real-time control of a standing surface acoustic wave field, which enables flexible manipulation of most known microparticles. The power density required by our acoustic device is significantly lower than its optical counterparts (10,000,000 times less than optical tweezers and 100 times less than optoelectronic tweezers), which renders the technique more biocompatible and amenable to miniaturization. Cell-viability tests were conducted to verify the tweezers’ compatibility with biological objects. With its advantages in biocompatibility, miniaturization, and versatility, the acoustic tweezers presented here will become a powerful tool for many disciplines of science and engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Observation of a single-beam gradient force optical trap for dielectric particles
Ashkin, A., Dziedzic, J. M., Bjorkholm, J. E., & Chu, S. (1986) · Optics Letters · doi:10.1364/ol.11.000288 · Cited by 7,030
A revolution in optical manipulation
Grier, D. G. (2003) · Nature · doi:10.1038/nature01935 · Cited by 5,123
Single-molecule force spectroscopy: optical tweezers, magnetic tweezers and atomic force microscopy
Neuman, K. C., & Nagy, A. (2008) · Nature Methods · doi:10.1038/nmeth.1218 · Cited by 2,406
Massively parallel manipulation of single cells and microparticles using optical images
Chiou, P. Y., Ohta, A. T., & Wu, M. C. (2005) · Nature · doi:10.1038/nature03831 · Cited by 1,444
Acoustofluidics 7: The acoustic radiation force on small particles
Bruus, H. (2012) · Lab on a Chip · doi:10.1039/c2lc21068a · Cited by 1,019
Microscale acoustofluidics: Microfluidics driven via acoustics and ultrasonics
Friend, J., & Yeo, L. Y. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.647 · Cited by 964
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892
Acoustic tweezers: patterning cells and microparticles using standing surface acoustic waves (SSAW)
Shi, J., Ahmed, D., Mao, X., Lin, S.-C. S., Lawit, A., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b910595f · Cited by 723
Self-citationShear-induced unfolding triggers adhesion of von Willebrand factor fibers
Schneider, S. W., Nuschele, S., Wixforth, A., Gorzelanny, C., Alexander-Katz, A., Netz, R. R., & Schneider, M. F. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608422104 · Cited by 702
Surface Acoustic Wave Devices for Mobile and Wireless Communications
Campbell, C. (1998) · Cited by 660
Microfluidics for in vivo imaging of neuronal and behavioral activity in Caenorhabditis elegans
Chronis, N., Zimmer, M., & Bargmann, C. I. (2007) · Nature Methods · doi:10.1038/nmeth1075 · Cited by 594
Continuous particle separation in a microfluidic channel via standing surface acoustic waves (SSAW)
Shi, J., Huang, H., Stratton, Z., Huang, Y., & Huang, T. J. (2009) · Lab on a Chip · doi:10.1039/b915113c · Cited by 547
Self-citationSubcellular positioning of small molecules
Takayama, S., Ostuni, E., LeDuc, P., Naruse, K., Ingber, D. E., & Whitesides, G. M. (2001) · Nature · doi:10.1038/35082637 · Cited by 545
Continuous separation of cells and particles in microfluidic systems
Lenshof, A., & Laurell, T. (2010) · Chemical Society Reviews · doi:10.1039/b915999c · Cited by 528
Mechanoenzymatic Cleavage of the Ultralarge Vascular Protein von Willebrand Factor
Zhang, X., Halvorsen, K., Zhang, C.-Z., Wong, W. P., & Springer, T. A. (2009) · Science · doi:10.1126/science.1170905 · Cited by 515
Trapping and rotating nanoparticles using a plasmonic nano-tweezer with an integrated heat sink
Wang, K., Schonbrun, E., Steinvurzel, P., & Crozier, K. B. (2011) · Nature Communications · doi:10.1038/ncomms1480 · Cited by 445
Focusing microparticles in a microfluidic channel with standing surface acoustic waves (SSAW)
Shi, J., Mao, X., Ahmed, D., Colletti, A., & Huang, T. J. (2008) · Lab Chip · doi:10.1039/b716321e · Cited by 439
Self-citationMagnetic manipulation of self-assembled colloidal asters
Snezhko, A., & Aranson, I. S. (2011) · Nature Materials · doi:10.1038/nmat3083 · Cited by 431
Micromechanical control of cell–cell interactions
Hui, E. E., & Bhatia, S. N. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608660104 · Cited by 390
Surface acoustic wave actuated cell sorting (SAWACS)
Franke, T., Braunmüller, S., Schmid, L., Wixforth, A., & Weitz, D. A. (2010) · Lab on a Chip · doi:10.1039/b915522h · Cited by 363
Acoustofluidics 8: Applications of acoustophoresis in continuous flow microsystems
Lenshof, A., Magnusson, C., & Laurell, T. (2012) · Lab on a Chip · doi:10.1039/c2lc21256k · Cited by 353
Automated on-chip rapid microscopy, phenotyping and sorting of C. elegans
Chung, K., Crane, M. M., & Lu, H. (2008) · Nature Methods · doi:10.1038/nmeth.1227 · Cited by 352
Rohde, C. B., Zeng, F., Gonzalez-Rubio, R., Angel, M., & Yanik, M. F. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706513104 · Cited by 295
Dynamic manipulation and separation of individual semiconducting and metallic nanowires
Jamshidi, A., Pauzauskie, P. J., Schuck, P. J., Ohta, A. T., Chiou, P.-Y., Chou, J., Yang, P., & Wu, M. C. (2008) · Nature Photonics · doi:10.1038/nphoton.2007.277 · Cited by 277
Acoustofluidics 5: Building microfluidic acoustic resonators
Lenshof, A., Evander, M., Laurell, T., & Nilsson, J. (2012) · Lab on a Chip · doi:10.1039/c1lc20996e · Cited by 252
Microfluidic Mixing via Acoustically Driven Chaotic Advection
Frommelt, T., Kostur, M., Wenzel-Schäfer, M., Talkner, P., Hänggi, P., & Wixforth, A. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.034502 · Cited by 248
Park, S., Zhang, Y., Wang, T.-H., & Yang, S. (2011) · Lab on a Chip · doi:10.1039/c1lc20307j · Cited by 241
Geometry-induced electrostatic trapping of nanometric objects in a fluid
Krishnan, M., Mojarad, N., Kukura, P., & Sandoghdar, V. (2010) · Nature · doi:10.1038/nature09404 · Cited by 240
Latest Developments in Microfluidic Cell Biology and Analysis Systems
Salieb-Beugelaar, G. B., Simone, G., Arora, A., Philippi, A., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac1009707 · Cited by 207
Shi, J., Yazdi, S., Steven Lin, S.-C., Ding, X., Chiang, I.-K., Sharp, K., & Huang, T. J. (2011) · Lab on a Chip · doi:10.1039/c1lc20042a · Cited by 207
Self-citationAcoustofluidics 1: Governing equations in microfluidics
Bruus, H. (2011) · Lab on a Chip · doi:10.1039/c1lc20658c · Cited by 191
Optical Tweezers Cause Physiological Damage to Escherichia coli and Listeria Bacteria
Rasmussen, M. B., Oddershede, L. B., & Siegumfeldt, H. (2008) · Applied and Environmental Microbiology · doi:10.1128/aem.02265-07 · Cited by 173
Uniform mixing in paper-based microfluidic systems using surface acoustic waves
Rezk, A. R., Qi, A., Friend, J. R., Li, W. H., & Yeo, L. Y. (2012) · Lab Chip · doi:10.1039/c2lc21065g · Cited by 164
Ultrasound-controlled cell aggregation in a multi-well chip
Vanherberghen, B., Manneberg, O., Christakou, A. E., Frisk, T. W., Ohlin, M., Hertz, H. M., Önfelt, B., & Wiklund, M. (2010) · Lab on a Chip · doi:10.1039/c004707d · Cited by 137
Ultrasonic standing wave manipulation technology integrated into a dielectrophoretic chip
Wiklund, M., Günther, C., Lemor, R. M., Jäger, M. S., Fuhr, G., & Hertz, H. M. (2006) · Lab on a Chip · doi:10.1039/b612064b · Cited by 137
Surface Acoustic Wave Driven Light Shutters Using Polymer‐Dispersed Liquid Crystals
Liu, Y., Ding, X., Lin, S. S., Shi, J., Chiang, I., & Huang, T. J. (2011) · Advanced Materials · doi:10.1002/adma.201003708 · Cited by 117
Self-citationScaling and Universality in the Optics of Disordered Exciton Chains
Klugkist, J. A., Malyshev, V. A., & Knoester, J. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.216403 · Cited by 62
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Holographic acoustic elements for manipulation of levitated objects
Marzo, A., Seah, S. A., Drinkwater, B. W., Sahoo, D. R., Long, B., & Subramanian, S. (2015) · Nature Communications · doi:10.1038/ncomms9661 · Cited by 943
Surface acoustic wave microfluidics
Ding, X., Li, P., Lin, S.-C. S., Stratton, Z. S., Nama, N., Guo, F., Slotcavage, D., Mao, X., Shi, J., Costanzo, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50361e · Cited by 926
Self-citationAcoustic tweezers for the life sciences
Ozcelik, A., Rufo, J., Guo, F., Gu, Y., Li, P., Lata, J., & Huang, T. J. (2018) · Nature Methods · doi:10.1038/s41592-018-0222-9 · Cited by 826
Self-citationSmall power: Autonomous nano- and micromotors propelled by self-generated gradients
Wang, W., Duan, W., Ahmed, S., Mallouk, T. E., & Sen, A. (2013) · Nano Today · doi:10.1016/j.nantod.2013.08.009 · Cited by 716
Metadata
- Authors
- Ding, X., Lin, S.-C. S., Kiraly, B., Yue, H., Li, S., Chiang, I.-K., Shi, J., Benkovic, S. J., & Huang, T. J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-06-25
- Volume
- 109
- Issue
- 28
- Pages
- 11105-11109
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2002287254
- Cited by
- 912
- References
- 37
- FWCI
- 30.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.