Atherosclerotic geometries exacerbate pathological thrombus formation poststenosis in a von Willebrand factor-dependent manner
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Rupture of a vulnerable atherosclerotic plaque causes thrombus formation and precipitates cardiovascular diseases. In addition to the thrombogenic content of a plaque, also the hemodynamic microenvironment plays a major role in thrombus formation. How the altered hemodynamics around a plaque promote pathological thrombus formation is not well understood. In this study, we provide evidence that plaque geometries result in fluid mechanical conditions that promote platelet aggregation and thrombus formation by increased accumulation and activity of von Willebrand factor (vWF) at poststenotic sites. Resonant-scanning multiphoton microscopy revealed that in vivo arterial stenosis of a damaged carotid artery markedly increased platelet aggregate formation in the stenotic outlet region. Complementary in vitro studies using microfluidic stenotic chambers, designed to mimic the flow conditions in a stenotic artery, showed enhanced platelet aggregation in the stenotic outlet region at 60–80% channel occlusion over a range of input wall shear rates. The poststenotic thrombus formation was critically dependent on bloodborne vWF and autocrine platelet stimulation. In stenotic chambers containing endothelial cells, flow provoked increased endothelial vWF secretion in the stenotic outlet region, contributing to exacerbated platelet aggregation. Taken together, this study identifies a role for the shear-sensitive protein vWF in transducing hemodynamic forces that are present around a stenosis to a prothrombogenic microenvironment resulting in spatially confined and exacerbated platelet aggregation in the stenosis outlet region. The developed stenotic microfluidic chamber offers a realistic platform for in vitro evaluation of shear-dependent thrombus formation in the setting of atherosclerosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Platelet-collagen interaction: is GPVI the central receptor?
Nieswandt, B., & Watson, S. P. (2003) · Blood · doi:10.1182/blood-2002-12-3882 · Cited by 1,150
Burke, A. P., Kolodgie, F. D., Farb, A., Weber, D. K., Malcom, G. T., Smialek, J., & Virmani, R. (2001) · Circulation · doi:10.1161/01.cir.103.7.934 · Cited by 919
A shear gradient–dependent platelet aggregation mechanism drives thrombus formation
Nesbitt, W. S., Westein, E., Tovar-Lopez, F. J., Tolouei, E., Mitchell, A., Fu, J., Carberry, J., Fouras, A., & Jackson, S. P. (2009) · Nature Medicine · doi:10.1038/nm.1955 · Cited by 862
Self-citationDong, J.-F., Moake, J. L., Nolasco, L., Bernardo, A., Arceneaux, W., Shrimpton, C. N., Schade, A. J., McIntire, L. V., Fujikawa, K., & López, J. A. (2002) · Blood · doi:10.1182/blood-2002-05-1401 · Cited by 857
Platelet aggregation in partially obstructed vessels and its elimination with aspirin.
Folts, J. D., Crowell, E. B., & Rowe, G. G. (1976) · Circulation · doi:10.1161/01.cir.54.3.365 · Cited by 750
The growing complexity of platelet aggregation
Jackson, S. P. (2007) · Blood · doi:10.1182/blood-2006-12-027698 · Cited by 737
Falati, S., Gross, P., Merrill-Skoloff, G., Furie, B. C., & Furie, B. (2002) · Nature Medicine · doi:10.1038/nm782 · Cited by 669
Apoptotic Vascular Endothelial Cells Become Procoagulant
Bombeli, T., Karsan, A., Tait, J. F., & Harlan, J. M. (1997) · Blood · doi:10.1182/blood.v89.7.2429 · Cited by 622
Platelet Activation and Blood Coagulation
Bevers, E., Lindhout, T., & Heemskerk, J. (2002) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1613209 · Cited by 584
Self-citationNi, H., Denis, C. V., Subbarao, S., Degen, J. L., Sato, T. N., Hynes, R. O., & Wagner, D. D. (2000) · Journal of Clinical Investigation · doi:10.1172/jci9896 · Cited by 492
Cited by
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Platelet biology and functions: new concepts and clinical perspectives
van der Meijden, P. E. J., & Heemskerk, J. W. M. (2019) · Nature Reviews Cardiology · doi:10.1038/s41569-018-0110-0 · Cited by 1,041
Self-citationEngineered In Vitro Disease Models
Benam, K. H., Dauth, S., Hassell, B., Herland, A., Jain, A., Jang, K.-J., Karalis, K., Kim, H. J., MacQueen, L., Mahmoodian, R., et al. (2015) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathol-012414-040418 · Cited by 554
Delivery of oligonucleotide‐based therapeutics: challenges and opportunities
Hammond, S. M., Aartsma‐Rus, A., Alves, S., Borgos, S. E., Buijsen, R. A. M., Collin, R. W. J., Covello, G., Denti, M. A., Desviat, L. R., Echevarría, L., et al. (2021) · EMBO Molecular Medicine · doi:10.15252/emmm.202013243 · Cited by 388
Microfluidic organ-on-chip technology for blood-brain barrier research
van der Helm, M. W., van der Meer, A. D., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I. (2016) · Tissue Barriers · doi:10.1080/21688370.2016.1142493 · Cited by 333
Self-citationFluid Mechanics of Blood Clot Formation
Fogelson, A. L., & Neeves, K. B. (2015) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010814-014513 · Cited by 302
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
“Finally, vascular MPS are used as models for arterial thrombosis (Huh et al., 2007; Westein et al., 2013).”
Current and future antiplatelet therapies: emphasis on preserving haemostasis
McFadyen, J. D., Schaff, M., & Peter, K. (2018) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2017.206 · Cited by 281
Costa, P. F., Albers, H. J., Linssen, J. E. A., Middelkamp, H. H. T., van der Hout, L., Passier, R., van den Berg, A., Malda, J., & van der Meer, A. D. (2017) · Lab on a Chip · doi:10.1039/c7lc00202e · Cited by 226
Marx, U. (2020) · ALTEX · doi:10.14573/altex.2001241 · Cited by 218
“…(Halaidych et al., 2018a,b); Cytostretch, a silicon-based modular customizable organ-on-chip platform (Gaio et al., 2016); thrombosis-on-chip model (Westein et al., 2013; Jain et al., 2016; Costa et al., 2017) and prediction of toxic side-effects (Barrile et al., 2018); high-throughput model for…”
BackgroundMicrofluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Jain, A., Graveline, A., Waterhouse, A., Vernet, A., Flaumenhaft, R., & Ingber, D. E. (2016) · Nature Communications · doi:10.1038/ncomms10176 · Cited by 182
“…after collagen coating, we still observed larger amounts of fibrin and platelet aggregates in the post-stenosed regions, which is consistent with past findings suggesting that the shear rate gradient in the decelerating flow region may be a major contributor to the haemostatic response 14,15 (Fig.”
Flow-induced stress on adherent cells in microfluidic devices
Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M. (2015) · Lab on a Chip · doi:10.1039/c5lc00633c · Cited by 144
Complex Tissue and Disease Modeling using hiPSCs
Passier, R., Orlova, V., & Mummery, C. (2016) · Cell Stem Cell · doi:10.1016/j.stem.2016.02.011 · Cited by 142
“…mimic the smallest functional subunits of human organ or tissue: the alveolus of a lung (lung-on-chip), synchronously contracting heart cells (heart-on-chip), intestine (guton-chip), and the like in a (micro)environment similar to that in vivo (Bhatia and Ingber, 2014; Wilmer et al., 2016).”
BackgroundBarrile, R., van der Meer, A. D., Park, H., Fraser, J. P., Simic, D., Teng, F., Conegliano, D., Nguyen, J., Jain, A., Zhou, M., et al. (2018) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.1054 · Cited by 138
“with human whole blood at physiologically relevant shear rates that recapitulate many of the key aspects of thrombosis.(24,25) In the present work, we explored whether this on-Chip model”
BackgroundMannino, R. G., Myers, D. R., Ahn, B., Wang, Y., Rollins, M., Gole, H., Lin, A. S., Guldberg, R. E., Giddens, D. P., Timmins, L. H., et al. (2015) · Scientific Reports · doi:10.1038/srep12401 · Cited by 127
Cardiac Tissues From Stem Cells: New Routes to Maturation and Cardiac Regeneration
Campostrini, G., Windt, L. M., van Meer, B. J., Bellin, M., & Mummery, C. L. (2021) · Circulation Research · doi:10.1161/circresaha.121.318183 · Cited by 96
Thrombosis-on-a-chip: prospective impact of microphysiological models of vascular thrombosis
Pandian, N. K. R., Mannino, R. G., Lam, W. A., & Jain, A. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.12.001 · Cited by 56
Metadata
- Authors
- Westein, E., van der Meer, A. D., Kuijpers, M. J. E., Frimat, J.-P., van den Berg, A., & Heemskerk, J. W. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2013-01-03
- Volume
- 110
- Issue
- 4
- Pages
- 1357-1362
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2127202845
- Cited by
- 304
- References
- 31
- FWCI
- 13.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.