Anisotropic particles align perpendicular to the flow direction in narrow microchannels
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The flow orientation of anisotropic particles through narrow channels is of importance in many fields, ranging from the spinning and molding of fibers to the flow of cells and proteins through thin capillaries. It is commonly assumed that anisotropic particles align parallel to the flow direction. When flowing through narrowed channel sections, one expects the increased flow rate to improve the parallel alignment. Here, we show by microfocus synchrotron X-ray scattering and polarized optical microscopy that anisotropic colloidal particles align perpendicular to the flow direction after passing a narrow channel section. We find this to be a general behavior of anisotropic colloids, which is also observed for disk-like particles. This perpendicular particle alignment is stable, extending downstream throughout the remaining part of the channel. We show by microparticle image velocimetry that the particle reorientation in the expansion zone after a narrow channel section occurs in a region with considerable extensional flow. This extensional flow is promoted by shear thinning, a typical property of complex fluids. Our discovery has important consequences when considering the flow orientation of polymers, micelles, fibers, proteins, or cells through narrow channels, pipes, or capillary sections. An immediate consequence for the production of fibers is the necessity for realignment by extension in the flow direction. For fibrous proteins, reorientation and stable plug flow are likely mechanisms for protein coagulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Physics of Liquid Crystals
Gennes, P. G. D., & Prost, J. (1993) · doi:10.1093/oso/9780198520245.001.0001 · Cited by 8,343
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379 · cited 1×
“Curr Opin Colloid Interface Sci 6(5-6):446–450.”
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Principles of Condensed Matter Physics
Chaikin, P. M., & Lubensky, T. C. (1995) · Cambridge University Press eBooks · doi:10.1017/cbo9780511813467 · Cited by 3,503
Brereton, M. G. (1978) · Physics Bulletin · doi:10.1088/0031-9112/29/1/038 · Cited by 3,229
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131 · cited 8×
“The shear rate-dependent viscosity used in our simulations was measured by using a cone-plate rheometer and fitting the measured flow curve to the Cross equation (see Supporting Information).”
BackgroundInfluentialStatics and Dynamics of Wormlike Surfactant Micelles
Zhang, W. (1999) · China Surfactant Detergent & Cosmetics · Cited by 1,096
Statics and dynamics of worm-like surfactant micelles
Cates, M. E., & Candau, S. J. (1990) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/2/33/001 · Cited by 1,080 · cited 1×
“For our first experiments, we chose cylindrical polymer micelles, a particularly well-suited model system for investigating the shear orientation of anisotropic particles (15).”
MethodAssembly mechanism of recombinant spider silk proteins
Rammensee, S., Slotta, U., Scheibel, T., & Bausch, A. R. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0709246105 · Cited by 363
Buffet, A., Rothkirch, A., Döhrmann, R., Körstgens, V., Abul Kashem, M. M., Perlich, J., Herzog, G., Schwartzkopf, M., Gehrke, R., Müller-Buschbaum, P., et al. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512016895 · Cited by 351 · cited 3×
“Buffet A, et al. (2012) P03, the microfocus and nanofocus X-ray scattering (MiNaXS) beamline of the PETRA III storage ring: The microfocus endstation.”
Self-citationStructure Formation in Polymeric Fibers
(2001) · Carl Hanser Verlag GmbH & Co. KG eBooks · doi:10.3139/9783446456808 · Cited by 262
Advanced Fiber Spinning Technology
(1994) · Elsevier eBooks · doi:10.1533/9781845693213 · Cited by 203
Small-angle options of the upgraded ultrasmall-angle x-ray scattering beamline BW4 at HASYLAB
Roth, S. V., Döhrmann, R., Dommach, M., Kuhlmann, M., Kröger, I., Gehrke, R., Walter, H., Schroer, C. G., Lengeler, B., & Müller‐Buschbaum, P. (2006) · Review of Scientific Instruments · doi:10.1063/1.2336195 · Cited by 171
Self-citationFörster, S., & Krämer, E. (1999) · Macromolecules · doi:10.1021/ma981597u · Cited by 125
Self-citationX-ray microfocussing combined with microfluidics for on-chip X-ray scattering measurements
Barrett, R., Fauçon, M., Lopez, J., Cristobal, G., Destremaut, F., Dodge, A., Guillot, P., Laval, P., Masselon, C., & Salmon, J. (2006) · Lab on a Chip · doi:10.1039/b517055a · Cited by 80 · cited 1×
“(9) have recently observed similar behavior for sodium dodecyl sulfate (SDS)/cetyltrimethylammonium chloride (CTAC) lamellae in a microfluidic test experiment at the Diamond synchrotron light source (United Kingdom).”
BackgroundMechanical mechanisms of thrombosis in intact bent microvessels of rat mesentery
Liu, Q., Mirc, D., & Fu, B. M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.06.013 · Cited by 59 · cited 1×
“For fibrous proteins, reorientation and stable plug flow are mechanisms for protein or cell coagulation with potential relations to thrombosis (26).”
BackgroundShear-Induced Demixing and Shear-Banding Instabilities in Dilute Triblock Copolymer Solutions
Waton, G., Michels, B., Steyer, A., & Schosseler, F. (2004) · Macromolecules · doi:10.1021/ma0349332 · Cited by 53
Direct investigation of anisotropic suspension structure in pressure-driven flow
Gao, C., Kulkarni, S. D., Morris, J. F., & Gilchrist, J. F. (2010) · Physical Review E · doi:10.1103/physreve.81.041403 · Cited by 51 · cited 1×
“In most cases of technological relevance, however, anisotropic particles are transported using pressure-driven flow (19, 20).”
BackgroundLi, S., Liu, N., Chan‐Park, M. B. E., Yan, Y., & Zhang, Q. (2007) · Nanotechnology · doi:10.1088/0957-4484/18/45/455302 · Cited by 34
Daubersies, L., Leng, J., & Salmon, J. (2012) · Lab on a Chip · doi:10.1039/c2lc41207a · Cited by 30
Cited by
Blanchet, C. E., Spilotros, A., Schwemmer, F., Graewert, M. A., Kikhney, A., Jeffries, C. M., Franke, D., Mark, D., Zengerle, R., Cipriani, F., et al. (2015) · Journal of Applied Crystallography · doi:10.1107/s160057671500254x · Cited by 589
Hydrodynamic alignment and assembly of nanofibrils resulting in strong cellulose filaments
Håkansson, K. M. O., Fall, A. B., Lundell, F., Yu, S., Krywka, C., Roth, S. V., Santoro, G., Kvick, M., Prahl Wittberg, L., Wågberg, L., et al. (2014) · Nature Communications · doi:10.1038/ncomms5018 · Cited by 523
Self-citationMittal, N., Ansari, F., Gowda.V, K., Brouzet, C., Chen, P., Larsson, P. T., Roth, S. V., Lundell, F., Wågberg, L., Kotov, N. A., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b01084 · Cited by 507
Self-citationBenecke, G., Wagermaier, W., Li, C., Schwartzkopf, M., Flucke, G., Hoerth, R., Zizak, I., Burghammer, M., Metwalli, E., Müller-Buschbaum, P., et al. (2014) · Journal of Applied Crystallography · doi:10.1107/s1600576714019773 · Cited by 333
Self-citationA Review on Graphene Fibers: Expectations, Advances, and Prospects
Fang, B., Chang, D., Xu, Z., & Gao, C. (2020) · Advanced Materials · doi:10.1002/adma.201902664 · Cited by 332
Metadata
- Authors
- Trebbin, M., Steinhauser, D., Perlich, J., Buffet, A., Roth, S. V., Zimmermann, W., Thiele, J., & Förster, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2013-04-08
- Volume
- 110
- Issue
- 17
- Pages
- 6706-6711
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2115675776
- Cited by
- 181
- References
- 21
- FWCI
- 9.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.