Block-Cell-Printing for live single-cell printing
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Significance: The ability of printing single-cell arrays with high precision and efficiency, single-cell resolution, multiple cell types, and maintenance of cell viability and function is essential for cell function and heterogeneity measurement. It is still hard for current methods to completely satisfy the above requirements. We report a unique live-cell printing technique, Block-Cell-Printing, that allows for convenient, precise, multiplexed, and high-throughput printing of functional single-cell arrays. Block-Cell-Printing has a minimum turnaround time of 0.5 h, a maximum resolution of 5 µm, and close to 100% cell viability. This method has been applied to study cell communications in heterotypic cell pairs with controlled morphology, characterize cells’ abilities to extend their membranes, and print primary neurons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Micropatterning as a tool to decipher cell morphogenesis and functions
Théry, M. (2010) · Journal of Cell Science · doi:10.1242/jcs.075150 · Cited by 730 · cited 1×
“Control of cell-pair distance is remarkably simple with BloCPrinting, providing a potential approach for studying cell–cell interaction (26, 27) and cell fusion (28).”
Background
Cited by
Recent advances in 3D printing of biomaterials
Chia, H. N., & Wu, B. M. (2015) · Journal of Biological Engineering · doi:10.1186/s13036-015-0001-4 · Cited by 1,734
Three-dimensional manipulation of single cells using surface acoustic waves
Guo, F., Mao, Z., Chen, Y., Xie, Z., Lata, J. P., Li, P., Ren, L., Liu, J., Yang, J., Dao, M., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1524813113 · Cited by 594
Two-dimensional single-cell patterning with one cell per well driven by surface acoustic waves
Collins, D. J., Morahan, B., Garcia-Bustos, J., Doerig, C., Plebanski, M., & Neild, A. (2015) · Nature Communications · doi:10.1038/ncomms9686 · Cited by 588
Recent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277
Bridging the gap: microfluidic devices for short and long distance cell–cell communication
Vu, T. Q., de Castro, R. M. B., & Qin, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01367h · Cited by 63
Self-citation
Metadata
- Authors
- Zhang, K., Chou, C.-K., Xia, X., Hung, M.-C., & Qin, L.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2014-02-10
- Volume
- 111
- Issue
- 8
- Pages
- 2948-2953
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2133359891
- Cited by
- 142
- References
- 1
- FWCI
- 7.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Block-Cell-Printing for live single-cell printing. https://app.cochat.ai/papers/10.1073/pnas.1313661111
- The paper
- Zhang, K., Chou, C.-K., Xia, X., Hung, M.-C., & Qin, L. (2014). Block-Cell-Printing for live single-cell printing. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1313661111
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.