The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Point-of-care diagnostics for noncommunicable diseases using synthetic urinary biomarkers and paper microfluidics
Open accessAbstract
Significance: Noncommunicable diseases, including cardiovascular disease and cancer, are growing worldwide but are challenging to diagnose because biomarkers that can accurately detect them in patients are lacking. Here, we designed nanoscale agents that are administered to reveal the presence of diseased tissues by producing a biomarker in the urine that can be detected using paper strips similar to a home pregnancy test. Using mouse models, we show that we can detect diseases as diverse as solid cancer and blood clots using only a single injection of our diagnostic followed by urine analysis on paper. This platform does not require expensive instruments, invasive procedures, or trained medical personnel, and may allow low-cost diagnosis of diseases at the point of care in resource-limited settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Projections of Global Mortality and Burden of Disease from 2002 to 2030
Mathers, C. D., & Loncar, D. (2006) · PLoS Medicine · doi:10.1371/journal.pmed.0030442 · Cited by 11,386
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
Noninvasive detection of clinically occult lymph-node metastases in prostate cancer
Harisinghani, M. G., Barentsz, J., Hahn, P. F., Deserno, W. M., Tabatabaei, S., van de Kaa, C. H., de la Rosette, J., & Weissleder, R. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022749 · Cited by 1,971
Integrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Cited by
Wood-Derived Materials for Green Electronics, Biological Devices, and Energy Applications
Zhu, H., Luo, W., Ciesielski, P. N., Fang, Z., Zhu, J. Y., Henriksson, G., Himmel, M. E., & Hu, L. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00225 · Cited by 1,532
Cancer biomarker detection: recent achievements and challenges
Wu, L., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00370e · Cited by 1,214
de Almeida, L. G. N., Thode, H., Eslambolchi, Y., Chopra, S., Young, D., Gill, S., Devel, L., & Dufour, A. (2022) · Pharmacological Reviews · doi:10.1124/pharmrev.121.000349 · Cited by 535
Renal clearable catalytic gold nanoclusters for in vivo disease monitoring
Loynachan, C. N., Soleimany, A. P., Dudani, J. S., Lin, Y., Najer, A., Bekdemir, A., Chen, Q., Bhatia, S. N., & Stevens, M. M. (2019) · Nature Nanotechnology · doi:10.1038/s41565-019-0527-6 · Cited by 515
Self-citationPoint-of-Care Diagnostics: Recent Developments in a Connected Age
Nayak, S., Blumenfeld, N. R., Laksanasopin, T., & Sia, S. K. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04630 · Cited by 508
Metadata
- Authors
- Warren, A. D., Kwong, G. A., Wood, D. K., Lin, K. Y., & Bhatia, S. N.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2014-02-24
- Volume
- 111
- Issue
- 10
- Pages
- 3671-3676
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2104169860
- Cited by
- 190
- References
- 4
- FWCI
- 10.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Point-of-care diagnostics for noncommunicable diseases using synthetic urinary biomarkers and paper microfluidics. https://app.cochat.ai/papers/10.1073/pnas.1314651111
- The paper
- Warren, A. D., Kwong, G. A., Wood, D. K., Lin, K. Y., & Bhatia, S. N. (2014). Point-of-care diagnostics for noncommunicable diseases using synthetic urinary biomarkers and paper microfluidics. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1314651111
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.