Resolution doubling in fluorescence microscopy with confocal spinning-disk image scanning microscopy
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Significance: Fluorescence microscopy is an enormously powerful tool for investigating structural organization and dynamical processes on the cellular level because of its noninvasiveness, sensitivity, and specificity. However, classical fluorescence microscopy is limited in resolution by the diffraction of light. In recent years, structural illumination microscopy has succeeded in doubling this resolution without requiring any special sample preparation or labeling dyes. However, it is technically very challenging and complex. Here, we present an alternative that achieves the same resolution enhancement by using a standard confocal spinning-disk microscope with minimal modifications. This method, in principle, allows one to double the resolution of any existing confocal microscope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772 · cited 2×
“Later, methods based on single-molecule localization, such as photoactivated localization microscopy (PALM) (2) and stochastic optical reconstruction microscopy (STORM) (3), joined the field.”
MethodSub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078 · cited 5×
“Rust MJ, Bates M, Zhuang X (2006) Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM).”
MethodInfluentialHell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065 · cited 1×
“The first of these superresolution methods was stimulated emission depletion (STED) microscopy (1).”
MethodBayesian-Based Iterative Method of Image Restoration*
Richardson, W. H. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.000055 · Cited by 4,160
An iterative technique for the rectification of observed distributions
Lucy, L. B. (1974) · The Astronomical Journal · doi:10.1086/111605 · Cited by 3,866
Gustafsson, M. G. L. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00710.x · Cited by 3,786 · cited 7×
“The most prominent example of this class is structured illumination microscopy (SIM) (5), in which one scans a sample with a structured illumination pattern while taking images with a wide-field imaging system.”
BackgroundInfluentialRichards, B., & Wolf, E. (1959) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1959.0200 · Cited by 3,095 · cited 3×
“For the Fourier reweighting, optical transfer functions were calculated using the wave optical theory by Wolf (27) and Richards and Wolf (28).”
MethodThe Nucleoporin RanBP2 Has SUMO1 E3 Ligase Activity
Pichler, A., Gast, A., Seeler, J. S., Dejean, A., & Melchior, F. (2002) · Cell · doi:10.1016/s0092-8674(01)00633-x · Cited by 816 · cited 11×
“The structure of the metazoan NPC has been studied intensively by (cryo)electron microscopy, which revealed the hourglass-like shape whose diameter ranges from ∼95 nm at the widest point to ∼50 nm at the narrowest point, at the center of the NPC (18, 19).”
MethodInfluentialElectromagnetic diffraction in optical systems - I. An integral representation of the image field
Wolf, E. (1959) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1959.0199 · Cited by 789 · cited 3×
“For the Fourier reweighting, optical transfer functions were calculated using the wave optical theory by Wolf (27) and Richards and Wolf (28).”
MethodMüller, C. B., & Enderlein, J. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.198101 · Cited by 521 · cited 4×
“63 (4) and 2 (6) were determined by measuring the apparent width of fluorescent beads (4, 6) and microtubules (6).”
BackgroundInfluentialSelf-citation
Cited by
Super-resolution microscopy demystified
Schermelleh, L., Ferrand, A., Huser, T., Eggeling, C., Sauer, M., Biehlmaier, O., & Drummen, G. P. C. (2019) · Nature Cell Biology · doi:10.1038/s41556-018-0251-8 · Cited by 1,211
Fast, long-term, super-resolution imaging with Hessian structured illumination microscopy
Huang, X., Fan, J., Li, L., Liu, H., Wu, R., Wu, Y., Wei, L., Mao, H., Lal, A., Xi, P., et al. (2018) · Nature Biotechnology · doi:10.1038/nbt.4115 · Cited by 661
Super-Resolution Structured Illumination Microscopy
Heintzmann, R., & Huser, T. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00218 · Cited by 574
Sparse deconvolution improves the resolution of live-cell super-resolution fluorescence microscopy
Zhao, W., Zhao, S., Li, L., Huang, X., Xing, S., Zhang, Y., Qiu, G., Han, Z., Shang, Y., Sun, D.-E., et al. (2022) · Nature Biotechnology · doi:10.1038/s41587-021-01092-2 · Cited by 408
Faster, sharper, and deeper: structured illumination microscopy for biological imaging
Wu, Y., & Shroff, H. (2018) · Nature Methods · doi:10.1038/s41592-018-0211-z · Cited by 375
An introduction to optical super-resolution microscopy for the adventurous biologist
Vangindertael, J., Camacho, R., Sempels, W., Mizuno, H., Dedecker, P., & Janssen, K. P. F. (2018) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/aaae0c · Cited by 208
“Müller and Enderlein addressed this issue by replacing the point detector by an imaging sensor in an approach called Image Scanning Microscopy (ISM) [62].”
BackgroundInfluentialLive-cell imaging powered by computation
Shroff, H., Testa, I., Jug, F., & Manley, S. (2024) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-024-00702-6 · Cited by 75
“has also been invented, using an array of excitation beamlets 87,88 , which enabled imaging of cytoskeletal microtubules and actin in 3D cultured cells and living zebrafish embryos at ~1 frame per second.”
Metadata
- Authors
- Schulz, O., Pieper, C., Clever, M., Pfaff, J., Ruhlandt, A., Kehlenbach, R. H., Wouters, F. S., Großhans, J., Bunt, G., & Enderlein, J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2013-12-09
- Volume
- 110
- Issue
- 52
- Pages
- 21000-21005
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2120995867
- Cited by
- 173
- References
- 32
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.