Microneedle-array patches loaded with hypoxia-sensitive vesicles provide fast glucose-responsive insulin delivery
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Significance: For exploiting synthetic glucose-responsive insulin delivery systems, challenges remain to demonstrate a strategy that would combine ( i ) fast responsiveness, ( ii ) ease of administration, and ( iii ) excellent biocompatibility. We have developed a novel glucose-responsive insulin delivery device using a painless microneedle-array patch containing hypoxia-sensitive hyaluronic acid-based vesicles. The vesicles quickly dissociate and release encapsulated insulin under the local hypoxic environment, caused by the enzymatic oxidation of glucose in the hyperglycemic state. This “smart insulin patch” with a new enzyme-based glucose-responsive mechanism can regulate the blood glucose of type 1 diabetic mice to achieve normal levels, with faster responsiveness compared with the commonly used pH-sensitive formulations, and can avoid the risk of hypoglycemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prausnitz, M. R., & Langer, R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1504 · Cited by 3,517
Ohkubo, Y., Kishikawa, H., Araki, E., Miyata, T., Isami, S., Motoyoshi, S., Kojima, Y., Furuyoshi, N., & Shichiri, M. (1995) · Diabetes Research and Clinical Practice · doi:10.1016/0168-8227(95)01064-k · Cited by 3,079
Prediabetes: a high-risk state for diabetes development
Tabák, A. G., Herder, C., Rathmann, W., Brunner, E. J., & Kivimäki, M. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60283-9 · Cited by 2,958
Type 2 diabetes: principles of pathogenesis and therapy
Stumvoll, M., Goldstein, B. J., & van Haeften, T. W. (2005) · The Lancet · doi:10.1016/s0140-6736(05)61032-x · Cited by 2,662
Microneedles for transdermal drug delivery
Prausnitz, M. R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,521
Khetan, S., Guvendiren, M., Legant, W. R., Cohen, D. M., Chen, C. S., & Burdick, J. A. (2013) · Nature Materials · doi:10.1038/nmat3586 · Cited by 1,168
A T cell-dependent experimental liver injury in mice inducible by concanavalin A.
Tiegs, G., Hentschel, J., & Wendel, A. (1992) · Journal of Clinical Investigation · doi:10.1172/jci115836 · Cited by 1,074
Chauhan, V. P., Martin, J. D., Liu, H., Lacorre, D. A., Jain, S. R., Kozin, S. V., Stylianopoulos, T., Mousa, A. S., Han, X., Adstamongkonkul, P., et al. (2013) · Nature Communications · doi:10.1038/ncomms3516 · Cited by 1,031
Drug permeation through human skin: Theory and invitro experimental measurement
Michaels, A. S., Chandrasekaran, S. K., & Shaw, J. E. (1975) · AIChE Journal · doi:10.1002/aic.690210522 · Cited by 801
ATP-triggered anticancer drug delivery
Mo, R., Jiang, T., DiSanto, R., Tai, W., & Gu, Z. (2014) · Nature Communications · doi:10.1038/ncomms4364 · Cited by 682
Self-citation
Cited by
Items 101–115 of 115
A self-adherent, bullet-shaped microneedle patch for controlled transdermal delivery of insulin
Seong, K.-Y., Seo, M.-S., Hwang, D. Y., O'Cearbhaill, E. D., Sreenan, S., Karp, J. M., & Yang, S. Y. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.03.041 · Cited by 170
“This cutaneous route could provide a comfortable and on-demand protein delivery in a non-invasive or minimally-invasive manner [2,7].”
BackgroundLeveraging Physiology for Precision Drug Delivery
Sun, W., Hu, Q., Ji, W., Wright, G., & Gu, Z. (2017) · Physiological Reviews · doi:10.1152/physrev.00015.2016 · Cited by 169
Self-citationCharge-switchable polymeric complex for glucose-responsive insulin delivery in mice and pigs
Wang, J., Yu, J., Zhang, Y., Zhang, X., Kahkoska, A. R., Chen, G., Wang, Z., Sun, W., Cai, L., Chen, Z., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw4357 · Cited by 168
Self-citationBio‐Inspired Ionic Skin for Theranostics
Lei, Z., Zhu, W., Zhang, X., Wang, X., & Wu, P. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008020 · Cited by 168
Electrospun Fibers Control Drug Delivery for Tissue Regeneration and Cancer Therapy
Li, L., Hao, R., Qin, J., Song, J., Chen, X., Rao, F., Zhai, J., Zhao, Y., Zhang, L., & Xue, J. (2022) · Advanced Fiber Materials · doi:10.1007/s42765-022-00198-9 · Cited by 168
Analgesic Microneedle Patch for Neuropathic Pain Therapy
Xie, X., Pascual, C., Lieu, C., Oh, S., Wang, J., Zou, B., Xie, J., Li, Z., Xie, J., Yeomans, D. C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06104 · Cited by 166
Synthetic “smart gel” provides glucose-responsive insulin delivery in diabetic mice
Matsumoto, A., Tanaka, M., Matsumoto, H., Ochi, K., Moro-oka, Y., Kuwata, H., Yamada, H., Shirakawa, I., Miyazawa, T., Ishii, H., et al. (2017) · Science Advances · doi:10.1126/sciadv.aaq0723 · Cited by 165
“For human use, combination with microneedle structures, among other possibilities,may provide an attractive solution to problems of scalability (owing to the large surface area of the microneedles), esthetic considerations, and the need to minimize invasiveness (11); in this manner, the scale discrepancy between mice…”
BackgroundChen, S., Fan, S., Qiao, Z., Wu, Z., Lin, B., Li, Z., Riegler, M. A., Wong, M. Y. H., Opheim, A., Korostynska, O., et al. (2025) · Advanced Materials · doi:10.1002/adma.202500412 · Cited by 164
Environment sensitive hydrogels for drug delivery applications
Qureshi, D., Nayak, S. K., Maji, S., Anis, A., Kim, D., & Pal, K. (2019) · European Polymer Journal · doi:10.1016/j.eurpolymj.2019.109220 · Cited by 159
Recent Advances in Microneedle Platforms for Transdermal Drug Delivery Technologies
Mdanda, S., Ubanako, P., Kondiah, P. P. D., Kumar, P., & Choonara, Y. E. (2021) · Polymers · doi:10.3390/polym13152405 · Cited by 159
“Type of Microneedle Materials Used References Disposable Carboxy-methyl-cellulose [29] Multi-round responsive Alginate [30] Temperature-r sponsive Vinyl pyrrolidone [31] Glucose-respon ive Hyaluronic acid [32] pH-responsive Hyaluronic acid [33] Swelling-shrinking Hydrogel [34] Water-solubl Dextrin [35]”
BackgroundA hypoxia responsive nanoassembly for tumor specific oxygenation and enhanced sonodynamic therapy
Yang, K., Yue, L., Yu, G., Rao, L., Tian, R., Wei, J., Yang, Z., Sun, C., Zhang, X., Xu, M., et al. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.120822 · Cited by 110
Yang, B., Kong, J., & Fang, X. (2019) · Talanta · doi:10.1016/j.talanta.2019.06.031 · Cited by 83
Wang, J., Wang, Z., Yu, J., Zhang, Y., Zeng, Y., & Gu, Z. (2019) · Biomaterials Science · doi:10.1039/c9bm01283d · Cited by 21
Self-citationRecent Progress in Glucose-Responsive Insulin
Liu, Y., Wang, S., Wang, Z., Yu, J., Wang, J., Buse, J. B., & Gu, Z. (2024) · Diabetes · doi:10.2337/dbi23-0028 · Cited by 19
Self-citationLong-acting glucose-responsive insulin with swift onset-of-action
Liu, W., Zhang, J., Wang, Y., He, Y., Wang, Y., Wei, X., Yao, Y., Xu, J., Zhang, W., Sheng, T., et al. (2025) · Journal of Controlled Release · doi:10.1016/j.jconrel.2025.113826 · Cited by 5
Self-citation
Metadata
- Authors
- Yu, J., Zhang, Y., Ye, Y., DiSanto, R., Sun, W., Ranson, D., Ligler, F. S., Buse, J. B., & Gu, Z.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2015-06-22
- Volume
- 112
- Issue
- 27
- Pages
- 8260-8265
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2146794940
- Cited by
- 848
- References
- 42
- FWCI
- 34.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).