The DOI matches its Crossref record.
Ultrahigh-resolution multicolor colocalization of single fluorescent probes
Open accessAbstract
An optical ruler based on ultrahigh-resolution colocalization of single fluorescent probes is described in this paper. It relies on the use of two unique families of fluorophores, namely energy-transfer fluorescent beads (TransFluoSpheres) and semiconductor nanocrystal quantum dots, that can be excited by a single laser wavelength but emit at different wavelengths. A multicolor sample-scanning confocal microscope was constructed that allows one to image each fluorescent light emitter, free of chromatic aberrations, by scanning the sample with nanometer scale steps with a piezo-scanner. The resulting spots are accurately localized by fitting them to the known shape of the excitation point-spread function of the microscope. We present results of two-dimensional colocalization of TransFluoSpheres (40 nm in diameter) and of nanocrystals (3–10 nm in diameter) and demonstrate distance-measurement accuracy of better than 10 nm using conventional far-field optics. This ruler bridges the gap between fluorescence resonance energy transfer, near- and far-field imaging, spanning a range of a few nanometers to tens of micrometers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Advances in fluorescence imaging with quantum dot bio-probes
Pinaud, F., Michalet, X., Bentolila, L. A., Tsay, J. M., Doose, S., Li, J. J., Iyer, G., & Weiss, S. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.018 · Cited by 441
Self-citationSubnanometre single-molecule localization, registration and distance measurements
Pertsinidis, A., Zhang, Y., & Chu, S. (2010) · Nature · doi:10.1038/nature09163 · Cited by 342
Time-gated biological imaging by use of colloidal quantum dots
Dahan, M., Laurence, T., Pinaud, F., Chemla, D. S., Alivisatos, A. P., Sauer, M., & Weiss, S. (2001) · Optics Letters · doi:10.1364/ol.26.000825 · Cited by 342
Self-citationImaging mass spectrometry in microbiology
Watrous, J. D., & Dorrestein, P. C. (2011) · Nature Reviews Microbiology · doi:10.1038/nrmicro2634 · Cited by 338
Metadata
- Authors
- Lacoste, T. D., Michalet, X., Pinaud, F., Chemla, D. S., Alivisatos, A. P., & Weiss, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2000-08-08
- Volume
- 97
- Issue
- 17
- Pages
- 9461-9466
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W4252617126
- Cited by
- 285
- References
- 0
- FWCI
- 11.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrahigh-resolution multicolor colocalization of single fluorescent probes. https://app.cochat.ai/papers/10.1073/pnas.170286097
- The paper
- Lacoste, T. D., Michalet, X., Pinaud, F., Chemla, D. S., Alivisatos, A. P., & Weiss, S. (2000). Ultrahigh-resolution multicolor colocalization of single fluorescent probes. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.170286097
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.