Capabilities for recording neural activity in behaving mammals have greatly expanded our understanding of brain function. Some of the most sophisticated approaches use light delivered by an implanted fiber-optic cable to optically excite genetically encoded calcium indicators and to record the resulting changes in fluorescence. Physical constraints induced by the cables and the bulk, size, and weight of the associated fixtures complicate studies on natural behaviors, including social interactions and movements in environments that include obstacles, housings, and other complex features. Here, we introduce a wireless, injectable fluorescence photometer that integrates a miniaturized light source and a photodetector on a flexible, needle-shaped polymer support, suitable for injection into the deep brain at sites of interest. The ultrathin geometry and compliant mechanics of these probes allow minimally invasive implantation and stable chronic operation. In vivo studies in freely moving animals demonstrate that this technology allows high-fidelity recording of calcium fluorescence in the deep brain, with measurement characteristics that match or exceed those associated with fiber photometry systems. The resulting capabilities in optical recordings of neuronal dynamics in untethered, freely moving animals have potential for widespread applications in neuroscience research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrasensitive fluorescent proteins for imaging neuronal activity
Chen, T.-W., Wardill, T. J., Sun, Y., Pulver, S. R., Renninger, S. L., Baohan, A., Schreiter, E. R., Kerr, R. A., Orger, M. B., Jayaraman, V., et al. (2013) · Nature · doi:10.1038/nature12354 · Cited by 6,474
Optogenetics in neural systems
Yizhar, O., Fenno, L. E., Davidson, T. J., Mogri, M., & Deisseroth, K. (2011) · Neuron · doi:10.1016/j.neuron.2011.06.004 · Cited by 1,881
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Self-citationNatural neural projection dynamics underlying social behavior
Gunaydin, L. A., Grosenick, L., Finkelstein, J. C., Kauvar, I. V., Fenno, L. E., Adhikari, A., Lammel, S., Mirzabekov, J. J., Airan, R. D., Zalocusky, K. A., et al. (2014) · Cell · doi:10.1016/j.cell.2014.05.017 · Cited by 1,389
Grienberger, C., & Konnerth, A. (2012) · Neuron · doi:10.1016/j.neuron.2012.02.011 · Cited by 1,354
Concurrent activation of striatal direct and indirect pathways during action initiation
Cui, G., Jun, S. B., Jin, X., Pham, M. D., Vogel, S. S., Lovinger, D. M., & Costa, R. M. (2013) · Nature · doi:10.1038/nature11846 · Cited by 1,301 · cited 2×
“Postshock signals (filled bars) have significantly higher events frequency compared with preshock signals (open bars) recorded from fiber photometry system [n = 7; paired t test, t(6) = 6.”
BackgroundAmygdala circuitry mediating reversible and bidirectional control of anxiety
Tye, K. M., Prakash, R., Kim, S.-Y., Fenno, L. E., Grosenick, L., Zarabi, H., Thompson, K. R., Gradinaru, V., Ramakrishnan, C., & Deisseroth, K. (2011) · Nature · doi:10.1038/nature09820 · Cited by 1,289
An Expanded Palette of Genetically Encoded Ca 2+ Indicators
Zhao, Y., Araki, S., Wu, J., Teramoto, T., Chang, Y.-F., Nakano, M., Abdelfattah, A. S., Fujiwara, M., Ishihara, T., Nagai, T., et al. (2011) · Science · doi:10.1126/science.1208592 · Cited by 1,260
Optimization of a GCaMP Calcium Indicator for Neural Activity Imaging
Akerboom, J., Chen, T.-W., Wardill, T. J., Tian, L., Marvin, J. S., Mutlu, S., Calderón, N. C., Esposti, F., Borghuis, B. G., Sun, X. R., et al. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.2601-12.2012 · Cited by 1,223
Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174
Self-citationMiniaturized integration of a fluorescence microscope
Ghosh, K. K., Burns, L. D., Cocker, E. D., Nimmerjahn, A., Ziv, Y., Gamal, A. E., & Schnitzer, M. J. (2011) · Nature Methods · doi:10.1038/nmeth.1694 · Cited by 1,120 · cited 2×
“The overall NEP value for the fiber photometry system will be similar to the NEP for the photoreceiver due to other noise and loss, such as a low transfer efficiency in fluorescence throughput to detector from fiber tip (∼20% in one reported case for fiber bundles) (4).”
BackgroundMethodImaging large-scale neural activity with cellular resolution in awake, mobile mice
Dombeck, D. A., Khabbaz, A. N., Collman, F., Adelman, T. L., & Tank, D. W. (2007) · Neuron · doi:10.1016/j.neuron.2007.08.003 · Cited by 1,099
Bolometers for infrared and millimeter waves
Richards, P. L. (1994) · Journal of Applied Physics · doi:10.1063/1.357128 · Cited by 901 · cited 1×
“The NEP of the wireless photometry system can be determined by reducing the intensity of the green light until the measurement yields a signal-to-noise ratio (SNR) of 1 at a frequency of 1 Hz (27).”
BackgroundSoft, stretchable, fully implantable miniaturized optoelectronic systems for wireless optogenetics
Park, S. I., Brenner, D. S., Shin, G., Morgan, C. D., Copits, B. A., Chung, H. U., Pullen, M. Y., Noh, K. N., Davidson, S., Oh, S. J., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3415 · Cited by 794 · cited 1×
“Possibilities for extended functional options will follow from integration of multiple μ-ILEDs or fluidic channels on the injectable probe needle to enable wireless optogenetic manipulation (16) or drug delivery (39), along with optical recording.”
BackgroundSelf-citationYaroslavsky, A. N., Schulze, P. C., Yaroslavsky, I. V., Schober, R., Ulrich, F., & Schwarzmaier, H.-J. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/12/305 · Cited by 651
GaAs photovoltaics and optoelectronics using releasable multilayer epitaxial assemblies
Yoon, J., Jo, S., Chun, I. S., Jung, I., Kim, H.-S., Meitl, M., Menard, E., Li, X., Coleman, J. J., Paik, U., et al. (2010) · Nature · doi:10.1038/nature09054 · Cited by 617 · cited 1×
“S4 provide a schematic illustration of the overall multilayer layout and geometry of the μ-IPD (15).”
BackgroundSelf-citationUltraflexible nanoelectronic probes form reliable, glial scar–free neural integration
Luan, L., Wei, X., Zhao, Z., Siegel, J. J., Potnis, O., Tuppen, C. A., Lin, S., Kazmi, S., Fowler, R. A., Holloway, S., et al. (2017) · Science Advances · doi:10.1126/sciadv.1601966 · Cited by 612 · cited 3×
“59 × 10 N·m(2) along the width and thickness directions, respectively (21, 22).”
BackgroundInfluentialVisualizing Hypothalamic Network Dynamics for Appetitive and Consummatory Behaviors
Jennings, J. H., Ung, R. L., Resendez, S. L., Stamatakis, A. M., Taylor, J. G., Huang, J., Veleta, K., Kantak, P. A., Aita, M., Shilling-Scrivo, K., et al. (2015) · Cell · doi:10.1016/j.cell.2014.12.026 · Cited by 542
High-speed in vivo calcium imaging reveals neuronal network activity with near-millisecond precision
Grewe, B. F., Langer, D., Kasper, H., Kampa, B. M., & Helmchen, F. (2010) · Nature Methods · doi:10.1038/nmeth.1453 · Cited by 522
Projections from neocortex mediate top-down control of memory retrieval
Rajasethupathy, P., Sankaran, S., Marshel, J. H., Kim, C. K., Ferenczi, E., Lee, S. Y., Berndt, A., Ramakrishnan, C., Jaffe, A., Lo, M., et al. (2015) · Nature · doi:10.1038/nature15389 · Cited by 509 · cited 1×
“For example, the addition of a red μ-ILED would enable simultaneously optogenetic stimulation with red-shifted channelrhodopsins (40) and Ca recording with GCaMP6 from dopaminergic neurons in the ventral tegmental area (VTA), allowing manipulating the response of optogenetic stimulation to match naturalistic VTA dopam…”
BackgroundWireless Optofluidic Systems for Programmable In Vivo Pharmacology and Optogenetics
Jeong, J.-W., McCall, J. G., Shin, G., Zhang, Y., Al-Hasani, R., Kim, M., Li, S., Sim, J. Y., Jang, K.-I., Shi, Y., et al. (2015) · Cell · doi:10.1016/j.cell.2015.06.058 · Cited by 498 · cited 1×
“Possibilities for extended functional options will follow from integration of multiple μ-ILEDs or fluidic channels on the injectable probe needle to enable wireless optogenetic manipulation (16) or drug delivery (39), along with optical recording.”
BackgroundSelf-citationSimultaneous fast measurement of circuit dynamics at multiple sites across the mammalian brain
Kim, C. K., Yang, S. J., Pichamoorthy, N., Young, N. P., Kauvar, I., Jennings, J. H., Lerner, T. N., Berndt, A., Lee, S. Y., Ramakrishnan, C., et al. (2016) · Nature Methods · doi:10.1038/nmeth.3770 · Cited by 441 · cited 10×
“S10), well matched to the fluorescence excitation source for many GECIs, including GCaMP6 (3, 23).”
BackgroundInfluentialShin, G., Gomez, A. M., Al-Hasani, R., Jeong, Y. R., Kim, J., Xie, Z., Banks, A., Lee, S. M., Han, S. Y., Yoo, C. J., et al. (2017) · Neuron · doi:10.1016/j.neuron.2016.12.031 · Cited by 396
Self-citationHigh-speed, miniaturized fluorescence microscopy in freely moving mice
Flusberg, B. A., Nimmerjahn, A., Cocker, E. D., Mukamel, E. A., Barretto, R. P. J., Ko, T. H., Burns, L. D., Jung, J. C., & Schnitzer, M. J. (2008) · Nature Methods · doi:10.1038/nmeth.1256 · Cited by 385 · cited 1×
“Other types of headmounted devices have considerably larger masses, typically >1 g (4, 5), than those reported here.”
BackgroundModeling the Spatiotemporal Dynamics of Light and Heat Propagation for In Vivo Optogenetics
Stujenske, J. M., Spellman, T., & Gordon, J. A. (2015) · Cell Reports · doi:10.1016/j.celrep.2015.06.036 · Cited by 383 · cited 1×
“For the photometry system, the μ-ILED operates at a much lower optical power (240 μW) with the same duty cycle of 20%; thus the thermal influence is minimal, as confirmed by simulation results where temperature increases are proportional to the blue light power (25).”
BackgroundMidbrain dopamine neurons control judgment of time
Soares, S., Atallah, B. V., & Paton, J. J. (2016) · Science · doi:10.1126/science.aah5234 · Cited by 360
Neural ensemble dynamics underlying a long-term associative memory
Grewe, B. F., Gründemann, J., Kitch, L. J., Lecoq, J. A., Parker, J. G., Marshall, J. D., Larkin, M. C., Jercog, P. E., Grenier, F., Li, J. Z., et al. (2017) · Nature · doi:10.1038/nature21682 · Cited by 351
Brain micromotion around implants in the rodent somatosensory cortex
Gilletti, A., & Muthuswamy, J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/3/001 · Cited by 307 · cited 2×
“Furthermore, mismatches between the mechanical properties of the soft, compliant tissues of the brain and the hard, rigid fiber probes result in unavoidable tissue damage with potential for implant detachment (13, 14).”
BackgroundLight Scattering Properties Vary across Different Regions of the Adult Mouse Brain
Al‐Juboori, S. I., Dondzillo, A., Stubblefield, E. A., Felsen, G., Lei, T. C., & Klug, A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0067626 · Cited by 163
Yona, G., Meitav, N., Kahn, I., & Shoham, S. (2016) · eNeuro · doi:10.1523/eneuro.0059-15.2015 · Cited by 134
Long-term changes in the material properties of brain tissue at the implant–tissue interface
Sridharan, A., Rajan, S. D., & Muthuswamy, J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066001 · Cited by 132 · cited 2×
“Furthermore, mismatches between the mechanical properties of the soft, compliant tissues of the brain and the hard, rigid fiber probes result in unavoidable tissue damage with potential for implant detachment (13, 14).”
BackgroundDeep brain optical measurements of cell type–specific neural activity in behaving mice
Cui, G., Jun, S. B., Jin, X., Luo, G., Pham, M. D., Lovinger, D. M., Vogel, S. S., & Costa, R. M. (2014) · Nature Protocols · doi:10.1038/nprot.2014.080 · Cited by 130
Effects of the beta-blocker propranolol on cued and contextual fear conditioning in humans
Grillon, C., Cordova, J., Morgan, C. A., Charney, D. S., & Davis, M. (2004) · Psychopharmacology · doi:10.1007/s00213-004-1819-5 · Cited by 122
Bush, D. E. A., Caparosa, E. M., Gekker, A., & LeDoux, J. (2010) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2010.00154 · Cited by 117
Fast calcium sensor proteins for monitoring neural activity
Badura, A., Sun, X. R., Giovannucci, A., Lynch, L. A., & Wang, S. S.-H. (2014) · Neurophotonics · doi:10.1117/1.nph.1.2.025008 · Cited by 116
Optodynamic simulation of β-adrenergic receptor signalling
Siuda, E. R., McCall, J. G., Al-Hasani, R., Shin, G., Il Park, S., Schmidt, M. J., Anderson, S. L., Planer, W. J., Rogers, J. A., & Bruchas, M. R. (2015) · Nature Communications · doi:10.1038/ncomms9480 · Cited by 99
Self-citationSiuda, E. R., Al‐Hasani, R., McCall, J. G., Bhatti, D. L., & Bruchas, M. R. (2016) · Neuropsychopharmacology · doi:10.1038/npp.2015.371 · Cited by 53
Self-citationMiniaturized optical neuroimaging in unrestrained animals
Yu, H., Senarathna, J., Tyler, B., Thakor, N. V., & Pathak, A. P. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.02.070 · Cited by 36
Sigal, I., Koletar, M. M., Ringuette, D., Gad, R., Jeffrey, M. A., Carlen, P. L., Stefanovic, B., & Levi, O. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003596 · Cited by 28 · cited 1×
“0002 for fiber photometry system; n = 12, unpaired t test, t(12) = 5.”
BackgroundChronic wide-field imaging of brain hemodynamics in behaving animals
Miao, P., Zhang, L., Li, M., Zhang, Y., Feng, S., Wang, Q., & Thakor, N. V. (2016) · Biomedical Optics Express · doi:10.1364/boe.8.000436 · Cited by 23 · cited 1×
“There is no significant difference between the two systems [n = 13, unpaired t test, t(11) = 1.”
Background
Cited by
Wireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Self-citationEmerging Modalities and Implantable Technologies for Neuromodulation
Won, S. M., Song, E., Reeder, J. T., & Rogers, J. A. (2020) · Cell · doi:10.1016/j.cell.2020.02.054 · Cited by 291
Self-citationNext-generation interfaces for studying neural function
Frank, J. A., Antonini, M.-J., & Anikeeva, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0198-8 · Cited by 241
Gutruf, P., Krishnamurthi, V., Vázquez-Guardado, A., Xie, Z., Banks, A., Su, C.-J., Xu, Y., Haney, C. R., Waters, E. A., Kandela, I., et al. (2018) · Nature Electronics · doi:10.1038/s41928-018-0175-0 · Cited by 210
Self-citationRecent advances in neurotechnologies with broad potential for neuroscience research
Vázquez-Guardado, A., Yang, Y., Bandodkar, A. J., & Rogers, J. A. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-00739-8 · Cited by 202
Self-citation
Metadata
- Authors
- Lu, L., Gutruf, P., Xia, L., Bhatti, D. L., Wang, X., Vazquez-Guardado, A., Ning, X., Shen, X., Sang, T., Ma, R., Pakeltis, G., Sobczak, G., Zhang, H., Seo, D.-O., Xue, M., Yin, L., Chanda, D., Sheng, X., Bruchas, M. R., & Rogers, J. A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2018-01-29
- Volume
- 115
- Issue
- 7
- Pages
- E1374-E1383
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2793670796
- Cited by
- 203
- References
- 40
- FWCI
- 11.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.