Wireless optoelectronic photometers for monitoring neuronal dynamics in the deep brain
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Capabilities for recording neural activity in behaving mammals have greatly expanded our understanding of brain function. Some of the most sophisticated approaches use light delivered by an implanted fiber-optic cable to optically excite genetically encoded calcium indicators and to record the resulting changes in fluorescence. Physical constraints induced by the cables and the bulk, size, and weight of the associated fixtures complicate studies on natural behaviors, including social interactions and movements in environments that include obstacles, housings, and other complex features. Here, we introduce a wireless, injectable fluorescence photometer that integrates a miniaturized light source and a photodetector on a flexible, needle-shaped polymer support, suitable for injection into the deep brain at sites of interest. The ultrathin geometry and compliant mechanics of these probes allow minimally invasive implantation and stable chronic operation. In vivo studies in freely moving animals demonstrate that this technology allows high-fidelity recording of calcium fluorescence in the deep brain, with measurement characteristics that match or exceed those associated with fiber photometry systems. The resulting capabilities in optical recordings of neuronal dynamics in untethered, freely moving animals have potential for widespread applications in neuroscience research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrasensitive fluorescent proteins for imaging neuronal activity
Chen, T.-W., Wardill, T. J., Sun, Y., Pulver, S. R., Renninger, S. L., Baohan, A., Schreiter, E. R., Kerr, R. A., Orger, M. B., Jayaraman, V., et al. (2013) · Nature · doi:10.1038/nature12354 · Cited by 6,474
Optogenetics in neural systems
Yizhar, O., Fenno, L. E., Davidson, T. J., Mogri, M., & Deisseroth, K. (2011) · Neuron · doi:10.1016/j.neuron.2011.06.004 · Cited by 1,881
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Self-citationNatural neural projection dynamics underlying social behavior
Gunaydin, L. A., Grosenick, L., Finkelstein, J. C., Kauvar, I. V., Fenno, L. E., Adhikari, A., Lammel, S., Mirzabekov, J. J., Airan, R. D., Zalocusky, K. A., et al. (2014) · Cell · doi:10.1016/j.cell.2014.05.017 · Cited by 1,389
Grienberger, C., & Konnerth, A. (2012) · Neuron · doi:10.1016/j.neuron.2012.02.011 · Cited by 1,354
Concurrent activation of striatal direct and indirect pathways during action initiation
Cui, G., Jun, S. B., Jin, X., Pham, M. D., Vogel, S. S., Lovinger, D. M., & Costa, R. M. (2013) · Nature · doi:10.1038/nature11846 · Cited by 1,301 · cited 2×
“Postshock signals (filled bars) have significantly higher events frequency compared with preshock signals (open bars) recorded from fiber photometry system [n = 7; paired t test, t(6) = 6.”
BackgroundAmygdala circuitry mediating reversible and bidirectional control of anxiety
Tye, K. M., Prakash, R., Kim, S.-Y., Fenno, L. E., Grosenick, L., Zarabi, H., Thompson, K. R., Gradinaru, V., Ramakrishnan, C., & Deisseroth, K. (2011) · Nature · doi:10.1038/nature09820 · Cited by 1,289
An Expanded Palette of Genetically Encoded Ca 2+ Indicators
Zhao, Y., Araki, S., Wu, J., Teramoto, T., Chang, Y.-F., Nakano, M., Abdelfattah, A. S., Fujiwara, M., Ishihara, T., Nagai, T., et al. (2011) · Science · doi:10.1126/science.1208592 · Cited by 1,260
Optimization of a GCaMP Calcium Indicator for Neural Activity Imaging
Akerboom, J., Chen, T.-W., Wardill, T. J., Tian, L., Marvin, J. S., Mutlu, S., Calderón, N. C., Esposti, F., Borghuis, B. G., Sun, X. R., et al. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.2601-12.2012 · Cited by 1,223
Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174
Self-citation
Cited by
Wireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Self-citationEmerging Modalities and Implantable Technologies for Neuromodulation
Won, S. M., Song, E., Reeder, J. T., & Rogers, J. A. (2020) · Cell · doi:10.1016/j.cell.2020.02.054 · Cited by 291
Self-citationNext-generation interfaces for studying neural function
Frank, J. A., Antonini, M.-J., & Anikeeva, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0198-8 · Cited by 241
Gutruf, P., Krishnamurthi, V., Vázquez-Guardado, A., Xie, Z., Banks, A., Su, C.-J., Xu, Y., Haney, C. R., Waters, E. A., Kandela, I., et al. (2018) · Nature Electronics · doi:10.1038/s41928-018-0175-0 · Cited by 210
Self-citationRecent advances in neurotechnologies with broad potential for neuroscience research
Vázquez-Guardado, A., Yang, Y., Bandodkar, A. J., & Rogers, J. A. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-00739-8 · Cited by 202
Self-citationHigh-density multi-fiber photometry for studying large-scale brain circuit dynamics
Sych, Y., Chernysheva, M., Sumanovski, L. T., & Helmchen, F. (2019) · Nature Methods · doi:10.1038/s41592-019-0400-4 · Cited by 201
An ultraflexible organic differential amplifier for recording electrocardiograms
Sugiyama, M., Uemura, T., Kondo, M., Akiyama, M., Namba, N., Yoshimoto, S., Noda, Y., Araki, T., & Sekitani, T. (2019) · Nature Electronics · doi:10.1038/s41928-019-0283-5 · Cited by 177
Wireless, battery-free optoelectronic systems as subdermal implants for local tissue oximetry
Zhang, H., Gutruf, P., Meacham, K., Montana, M. C., Zhao, X., Chiarelli, A. M., Vázquez-Guardado, A., Norris, A., Lu, L., Guo, Q., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw0873 · Cited by 173
“2019;5 : eaaw0873 8 March 2019 efficacy of these coating materials has been evaluated on related functional implants in the brains of living animalmodels in previous reports (14, 18, 25).”
BackgroundMethodInfluentialSelf-citationBiointegrated and Wirelessly Powered Implantable Brain Devices: A Review
Das, R., Moradi, F., & Heidari, H. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2966920 · Cited by 172
“[151], simultaneous multichannel optogenetics stimulation and multichannel electrical recording system [152].”
BackgroundDepth-resolved fiber photometry with a single tapered optical fiber implant
Pisano, F., Pisanello, M., Lee, S. J., Lee, J., Maglie, E., Balena, A., Sileo, L., Spagnolo, B., Bianco, M., Hyun, M., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0581-x · Cited by 161
Conformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113
Leveraging calcium imaging to illuminate circuit dysfunction in addiction
Siciliano, C. A., & Tye, K. M. (2019) · Alcohol · doi:10.1016/j.alcohol.2018.05.013 · Cited by 53
Recent advances in recording and modulation technologies for next-generation neural interfaces.
Hong, J.-W., Yoon, C., Jo, K., Won, J. H., & Park, S. (2021) · iScience · doi:10.1016/j.isci.2021.103550 · Cited by 25
Metadata
- Authors
- Lu, L., Gutruf, P., Xia, L., Bhatti, D. L., Wang, X., Vazquez-Guardado, A., Ning, X., Shen, X., Sang, T., Ma, R., Pakeltis, G., Sobczak, G., Zhang, H., Seo, D.-O., Xue, M., Yin, L., Chanda, D., Sheng, X., Bruchas, M. R., & Rogers, J. A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2018-01-29
- Volume
- 115
- Issue
- 7
- Pages
- E1374-E1383
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2793670796
- Cited by
- 203
- References
- 40
- FWCI
- 11.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.