Toward detecting and identifying macromolecules in a cellular context: Template matching applied to electron tomograms
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Electron tomography is the only technique available that allows us to visualize the three-dimensional structure of unfixed and unstained cells currently with a resolution of 6–8 nm, but with the prospect to reach 2–4 nm. This raises the possibility of detecting and identifying specific macromolecular complexes within their cellular context by virtue of their structural signature. Templates derived from the high-resolution structure of the molecule under scrutiny are used to search the reconstructed volume. Here we outline and test a computationally feasible two-step procedure: In a first step, mean-curvature motion is used for segmentation, yielding subvolumes that contain with a high probability macromolecules in the expected size range. Subsequently, the particles contained in the subvolumes are identified by cross-correlation, using a set of three-dimensional templates. With simulated and real tomographic data we demonstrate that such an approach is feasible and we explore the detection limits. Even structurally similar particles, such as the thermosome, GroEL, and the 20S proteasome can be identified with high fidelity. This opens up exciting prospects for mapping the territorial distribution of macromolecules and for analyzing molecular interactions in situ .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zimmerman, S. B., & Trach, S. O. (1991) · Journal of Molecular Biology · doi:10.1016/0022-2836(91)90499-v · Cited by 1,337
Cited by
Macromolecular Architecture in Eukaryotic Cells Visualized by Cryoelectron Tomography
Medalia, O., Weber, I., Frangakis, A. S., Nicastro, D., Gerisch, G., & Baumeister, W. (2002) · Science · doi:10.1126/science.1076184 · Cited by 837
Self-citationSTRUCTURAL STUDIES BY ELECTRON TOMOGRAPHY: From Cells to Molecules
Lučić, V., Förster, F., & Baumeister, W. (2005) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.73.011303.074112 · Cited by 702
Self-citationFrom words to literature in structural proteomics
Sali, A., Glaeser, R., Earnest, T., & Baumeister, W. (2003) · Nature · doi:10.1038/nature01513 · Cited by 475
Self-citationFocused ion beam micromachining of eukaryotic cells for cryoelectron tomography
Rigort, A., Bäuerlein, F. J. B., Villa, E., Eibauer, M., Laugks, T., Baumeister, W., & Plitzko, J. M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201333109 · Cited by 430
Self-citationNoise Reduction in Electron Tomographic Reconstructions Using Nonlinear Anisotropic Diffusion
Frangakis, A. S., & Hegerl, R. (2001) · Journal of Structural Biology · doi:10.1006/jsbi.2001.4406 · Cited by 423
Self-citation(2006) · doi:10.1007/978-0-387-69008-7 · Cited by 357
Single-Particle Imaging of Macromolecules by Cryo-Electron Microscopy
Frank, J. (2002) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.31.082901.134202 · Cited by 336
Handbook of Mathematical Methods in Imaging
(2011) · Springer eBooks · doi:10.1007/978-0-387-92920-0 · Cited by 334
The promise and the challenges of cryo‐electron tomography
Turk, M., & Baumeister, W. (2020) · FEBS Letters · doi:10.1002/1873-3468.13948 · Cited by 333
Self-citationNephrin strands contribute to a porous slit diaphragm scaffold as revealed by electron tomography
Wartiovaara, J., Öfverstedt, L.-G., Khoshnoodi, J., Zhang, J., Mäkelä, E., Sandin, S., Ruotsalainen, V., Cheng, R. H., Jalanko, H., Skoglund, U., et al. (2004) · Journal of Clinical Investigation · doi:10.1172/jci22562 · Cited by 319
Cryo-Electron Tomography: Can it Reveal the Molecular Sociology of Cells in Atomic Detail?
Beck, M., & Baumeister, W. (2016) · Trends in Cell Biology · doi:10.1016/j.tcb.2016.08.006 · Cited by 316
Self-citationA molecular census of 26 S proteasomes in intact neurons
Asano, S., Fukuda, Y., Beck, F., Aufderheide, A., Förster, F., Danev, R., & Baumeister, W. (2015) · Science · doi:10.1126/science.1261197 · Cited by 311
Self-citationEbersbach, G., Briegel, A., Jensen, G. J., & Jacobs-Wagner, C. (2008) · Cell · doi:10.1016/j.cell.2008.07.016 · Cited by 291
Studer, D., Humbel, B. M., & Chiquet, M. (2008) · Histochemistry and Cell Biology · doi:10.1007/s00418-008-0500-1 · Cited by 286
The native 3D organization of bacterial polysomes
Brandt, F., Etchells, S. A., Ortiz, J. O., Elcock, A. H., Hartl, F. U., & Baumeister, W. (2009) · Cell · doi:10.1016/j.cell.2008.11.016 · Cited by 258
“A comprehensive interpretation of tomograms is achieved by pattern recognition based on crosscorrelation between a known high-resolution structure and target structures in the tomogram, as demonstrated with macromolecular complexes enclosed in phantom cells (Bohm et al., 2000; Frangakis et al., 2002).”
Cryo-Electron Tomography and Subtomogram Averaging
Wan, W., & Briggs, J. A. G. (2016) · Methods in Enzymology · doi:10.1016/bs.mie.2016.04.014 · Cited by 278
Imaging whole Escherichia coli bacteria by using single-particle x-ray diffraction
Miao, J., Hodgson, K. O., Ishikawa, T., Larabell, C. A., LeGros, M. A., & Nishino, Y. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.232691299 · Cited by 276
Identification of macromolecular complexes in cryoelectron tomograms of phantom cells
Frangakis, A. S., Böhm, J., Förster, F., Nickell, S., Nicastro, D., Typke, D., Hegerl, R., & Baumeister, W. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.172520299 · Cited by 267
Self-citationA structural perspective on protein–protein interactions
Russell, R. B., Alber, F., Aloy, P., Davis, F. P., Korkin, D., Pichaud, M., Topf, M., & Sali, A. (2004) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2004.04.006 · Cited by 260
A complete data processing workflow for cryo-ET and subtomogram averaging
Chen, M., Bell, J. M., Shi, X., Sun, S. Y., Wang, Z., & Ludtke, S. J. (2019) · Nature Methods · doi:10.1038/s41592-019-0591-8 · Cited by 253
Integrating diverse data for structure determination of macromolecular assemblies
Alber, F., Förster, F., Korkin, D., Topf, M., & Sali, A. (2008) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.060407.135530 · Cited by 206
Robust membrane detection based on tensor voting for electron tomography
Martinez-Sanchez, A., Garcia, I., Asano, S., Lucic, V., & Fernandez, J.-J. (2014) · Journal of Structural Biology · doi:10.1016/j.jsb.2014.02.015 · Cited by 205
Metadata
- Authors
- Böhm, J., Frangakis, A. S., Hegerl, R., Nickell, S., Typke, D., & Baumeister, W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2000-11-21
- Volume
- 97
- Issue
- 26
- Pages
- 14245-14250
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2126919547
- Cited by
- 242
- References
- 1
- FWCI
- 10.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.