Imaging whole Escherichia coli bacteria by using single-particle x-ray diffraction
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
We report the first experimental recording, to our knowledge, of the diffraction pattern from intact Escherichia coli bacteria using coherent x-rays with a wavelength of 2 Å. By using the oversampling phasing method, a real space image at a resolution of 30 nm was directly reconstructed from the diffraction pattern. An R factor used for characterizing the quality of the reconstruction was in the range of 5%, which demonstrated the reliability of the reconstruction process. The distribution of proteins inside the bacteria labeled with manganese oxide has been identified and this distribution confirmed by fluorescence microscopy images. Compared with lens-based microscopy, this diffraction-based imaging approach can examine thicker samples, such as whole cultured cells, in three dimensions with resolution limited only by radiation damage. Looking forward, the successful recording and reconstruction of diffraction patterns from biological samples reported here represent an important step toward the potential of imaging single biomolecules at near-atomic resolution by combining single-particle diffraction with x-ray free electron lasers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Potential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022
Miao, J., Charalambous, P., Kirz, J., & Sayre, D. (1999) · Nature · doi:10.1038/22498 · Cited by 1,976
Self-citationHenderson, R. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s003358350000305x · Cited by 1,194
Hochuli, E., Döbeli, H., & Schacher, A. (1987) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)93969-4 · Cited by 1,112
Multicolor and Electron Microscopic Imaging of Connexin Trafficking
Gaietta, G., Deerinck, T. J., Adams, S. R., Bouwer, J., Tour, O., Laird, D. W., Sosinsky, G. E., Tsien, R. Y., & Ellisman, M. H. (2002) · Science · doi:10.1126/science.1068793 · Cited by 907
Soft X-ray microscopes and their biological applications
Kirz, J., Jacobsen, C., & Howells, M. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500003139 · Cited by 672
Marsh, B. J., Mastronarde, D. N., Buttle, K. F., Howell, K. E., & McIntosh, J. R. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.051631998 · Cited by 356
High Resolution 3D X-Ray Diffraction Microscopy
Miao, J., Ishikawa, T., Johnson, B., Anderson, E. H., Lai, B., & Hodgson, K. O. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.088303 · Cited by 331
Self-citationBöhm, J., Frangakis, A. S., Hegerl, R., Nickell, S., Typke, D., & Baumeister, W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.230282097 · Cited by 242
High resolution protein localization using soft X‐ray microscopy
Meyer‐Ilse, W., Hamamoto, D., Nair, A., Lelièvre, S. A., Denbeaux, G., Johnson, L., Pearson, A. L., Yager, D., Legros, M. A., & Larabell, C. A. (2001) · Journal of Microscopy · doi:10.1046/j.1365-2818.2001.00845.x · Cited by 197
Self-citationMicroholography of Living Organisms
Solem, J. C., & Baldwin, G. C. (1982) · Science · doi:10.1126/science.218.4569.229 · Cited by 164
Miao, J., Hodgson, K. O., & Sayre, D. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.111083998 · Cited by 154
Self-citationCharacterisation of an improved two-dimensional p22121 crystal from bovine rhodopsin
Krebs, A., Villa, C., Edwards, P. C., & Schertler, G. F. X. (1998) · Journal of Molecular Biology · doi:10.1006/jmbi.1998.2070 · Cited by 109
Atomic Resolution Three-Dimensional Electron Diffraction Microscopy
Miao, J., Ohsuna, T., Terasaki, O., Hodgson, K. O., & O’Keefe, M. A. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.155502 · Cited by 58
Self-citation
Cited by
High-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321
Femtosecond diffractive imaging with a soft-X-ray free-electron laser
Chapman, H. N., Barty, A., Bogan, M. J., Boutet, S., Frank, M., Hau-Riege, S. P., Marchesini, S., Woods, B. W., Bajt, S., Benner, W. H., et al. (2006) · Nature Physics · doi:10.1038/nphys461 · Cited by 1,026
Self-citationSmall-angle scattering studies of biological macromolecules in solution
Svergun, D. I., & Koch, M. H. J. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/10/r05 · Cited by 1,014
Hard-X-Ray Lensless Imaging of Extended Objects
Rodenburg, J. M., Hurst, A. C., Cullis, A. G., Dobson, B. R., Pfeiffer, F., Bunk, O., David, C., Jefimovs, K., & Johnson, I. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.034801 · Cited by 855
Soft X-ray microscopy at a spatial resolution better than 15 nm
Chao, W., Harteneck, B. D., Liddle, J. A., Anderson, E. H., & Attwood, D. T. (2005) · Nature · doi:10.1038/nature03719 · Cited by 851
Metadata
- Authors
- Miao, J., Hodgson, K. O., Ishikawa, T., Larabell, C. A., LeGros, M. A., & Nishino, Y.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2002-12-23
- Volume
- 100
- Issue
- 1
- Pages
- 110-112
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2167709977
- Cited by
- 276
- References
- 14
- FWCI
- 6.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.