Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies
Open accessAbstract
Arrays of micrometer-scale needles could be used to deliver drugs, proteins, and particles across skin in a minimally invasive manner. We therefore developed microfabrication techniques for silicon, metal, and biodegradable polymer microneedle arrays having solid and hollow bores with tapered and beveled tips and feature sizes from 1 to 1,000 μm. When solid microneedles were used, skin permeability was increased in vitro by orders of magnitude for macromolecules and particles up to 50 nm in radius. Intracellular delivery of molecules into viable cells was also achieved with high efficiency. Hollow microneedles permitted flow of microliter quantities into skin in vivo , including microinjection of insulin to reduce blood glucose levels in diabetic rats.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Fabrication of 3D microneedle electrodes by assembling 2D probe combs or etching bulk materials is expensive and time consuming.
“Because these approaches require special equipment or platforms, microneedle structures that are fabricated either by assembling 2D probe combs or etching bulk materials are expensive and time consuming.”
From A flexible three-dimensional electrode mesh: An enabling technology for wireless brain–computer interface prostheses (2016) · cites this paper as [10]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
The Properties of Gases and Liquids
Reid, R. C., SHERWOOD, T. K., & Street, R. E. (1959) · Physics Today · doi:10.1063/1.3060771 · Cited by 14,165 · see citing works
Biomaterials Science: An Introduction to Materials in Medicine
Ratner, B. D., Hoffman, A. S., Schöen, F. J., & Lemons, J. E. (1996) · doi:10.1016/c2009-0-02433-7 · Cited by 5,125 · see citing works
Fundamentals of Microfabrication
Giurgiutiu, V., & Lyshevski, S. E. (2016) · CRC Press eBooks · doi:10.1201/b15830-17 · Cited by 2,116 · see citing works
Rook, A., Wilkinson, D. S., & Ebling, F. J. G. (1968) · Medical Entomology and Zoology · Cited by 1,592 · see citing works
Microfabricated Microneedles: A Novel Approach to Transdermal Drug Delivery
Henry, S., McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js980042+ · Cited by 1,350 · see citing works
Self-citationLack of Pain Associated with Microfabricated Microneedles
Kaushik, S., Hord, A. H., Denson, D. D., et al. (2001) · Anesthesia & Analgesia · doi:10.1213/00000539-200102000-00041 · Cited by 450 · see citing works
Lack of Pain Associated with Microfabricated Microneedles
Kaushik, S., Hord, A. H., Denson, D. D., et al. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200102000-00041 · Cited by 448 · see citing works
Prediction of diffusion coefficients of proteins
Tyn, M. T., & Gusek, T. W. (1990) · Biotechnology and Bioengineering · doi:10.1002/bit.260350402 · Cited by 429 · see citing works
Mikszta, J. A., Alarcon, J. B., Brittingham, J. M., Sutter, D. E., Pettis, R. J., & Harvey, N. G. (2002) · Nature Medicine · doi:10.1038/nm0402-415 · Cited by 398 · see citing works
Ratner, B. D., Hoffman, A. S., Schöen, F. J., & Lemons, J. E. (1996) · Elsevier eBooks · doi:10.1016/b978-012582460-6/50002-5 · Cited by 386 · see citing works
Matriano, J. A., Cormier, M., Johnson, J., Young, W. A., Buttery, M., Nyam, K., & Daddona, P. E. (2002) · Pharmaceutical Research · doi:10.1023/a:1013607400040 · Cited by 374 · see citing works
Microfabricated Microneedles for Gene and Drug Delivery
McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.289 · Cited by 333 · see citing works
Self-citationA multichannel neural probe for selective chemical delivery at the cellular level
Chen, J., Wise, K. D., Hetke, J. F., & Bledsoe, S. C. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605435 · Cited by 285 · see citing works
Silicon-processed microneedles
Lin, L., & Pisano, A. P. (1999) · Journal of Microelectromechanical Systems · doi:10.1109/84.749406 · Cited by 250 · see citing works
Micromachined electrodes for biopotential measurements
Griss, P., Enoksson, P., Tolvanen-Laakso, H., Meriläinen, P., Ollmar, S., & Stemme, G. (2001) · Journal of Microelectromechanical Systems · doi:10.1109/84.911086 · Cited by 240 · see citing works
(2005) · CRC Press eBooks · doi:10.1201/9780849359033 · Cited by 234 · see citing works
DIABETES MELLITUS: DIAGNOSIS AND TREATMENT
(1979) · Inpharma Weekly · doi:10.1007/bf03301647 · Cited by 210 · see citing works
The Some Aspects of Diffusion in Solution and a Definition of a Colloidal Particle.
Polson, A. (1950) · The Journal of Physical Chemistry · doi:10.1021/j150479a007 · Cited by 168 · see citing works
Advanced Micropipette Techniques for Cell Physiology
Brown, K. T., & Flaming, D. G. (1987) · Works - Scholarship, Research, & Creative Expression (Swarthmore College) · Cited by 132 · see citing works
Genetic transformation of nematodes using arrays of micromechanical piercing structures.
Hashmi, S., Ling, P., Hashmi, G. P., et al. (1995) · PubMed · Cited by 116 · see citing works
Transdermal delivery of peptide and protein drugs: An overview
Amsden, B. G., & Goosen, M. F. A. (1995) · AIChE Journal · doi:10.1002/aic.690410814 · Cited by 90 · see citing works
Micromachined needle arrays for drug delivery or fluid extraction
Brazzle, J. D., Papautsky, I., & Frazier, A. B. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.805145 · Cited by 56 · see citing works
Hindered diffusion in slit pores: an analytical result
Pawar, Y., & Anderson, J. L. (1993) · Industrial & Engineering Chemistry Research · doi:10.1021/ie00016a023 · Cited by 44 · see citing works
Telemedicine applications in otoloryngology
Heneghan, C., Sclafani, A. P., Stern, J. C., et al. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.775489 · Cited by 33 · see citing works
Roy, P. K., Fujita, M., Imasaki, K., et al. (1999) · Japanese Journal of Applied Physics · doi:10.1143/jjap.38.279 · Cited by 5 · see citing works
The African American HIV University. Breaking myths about HIV.
Van Atta, M. (2001) · PubMed · Cited by 1 · see citing works
Flagged first, then by citations
Research works printed but not linked: 7
- Chen, J. & Wise, K. D. (1997) IEEE Trans. Biomed. Eng. 44, 760-769.
- Brazzle, J., Papautsky, I. & Frazier, A. B. (1999) IEEE Eng. Med. Biol. Mag. 18, 53-58.
- Lin, L. & Pisano, A. P. (1999) IEEE J. Micromech. Syst. 8, 78-84.
- Stoeber, B. & Liepmann, D. (2000) Proc. ASME MEMS Dev. 2000 IMECE 2, 355-359.
- McAllister, D. V. (2000) Ph.D. thesis (Georgia Institute of Technology, Atlanta).
- McAllister, D. V., Cros, F., Davis, S. P., Latta, L. M., Prausnitz, M. R. & Allen, M. G. (2000) in Transducers '99: 10th International Conference on Solid-State Sensors and Actuators (Elsevier, Lausanne, Switzerland), pp. 1098-1101.
- Park, J. H., Davis, S. P., Yoon, Y. K., Prausnitz, M. R. & Allen, M. G. (2003) in The 16th Annual International Conference on Micro Electro Mechanical Systems (IEEE, Piscataway, NJ), pp. 371-374.
Cited by
Sorted by citations
Suprachoroidal drug delivery to the back of the eye using hollow microneedles
Patel, S. R., Lin, A. S. P., Edelhauser, H. F., & Prausnitz, M. R. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0271-y · Cited by 330 · see citing works
Self-citationXiang, Z., Liu, J., & Lee, C. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.12 · Cited by 100 · see citing works
Aponte, V. M., Finch, D. S., & Klaus, D. M. (2006) · Life Sciences · doi:10.1016/j.lfs.2006.04.007 · Cited by 51 · see citing works
Varying-Length Polymer Microneedle Arrays Fabricated by Droplet Backside Exposure
Kwon, K. Y., Weber, A., & Li, W. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2352412 · Cited by 23 · see citing works
- Authors
- McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R.
- Affiliations
- Georgia Institute of Technology (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2003-11-17
- Volume
- 100
- Issue
- 24
- Pages
- 13755-13760
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC283494
- OpenAlex
- W2147323866
- Cited by
- 859
- References
- 27
- Citations by year
- 2026: 33 · 2025: 38 · 2024: 47 · 2023: 36 · 2022: 38 · 2021: 50 · 2020: 37 · 2019: 37 · 2018: 34 · 2017: 32 · 2016: 38 · 2015: 35 · 2014: 34 · 2013: 50 · 2012: 38
- FWCI
- 22.61
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- American Diabetes Association
- National Institutes of Health
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advancements in Transdermal Drug Delivery
- Health Sciences › Medicine › Emergency Medicine › Intramuscular injections and effects
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
- Keywords
- microneedle arrays, transdermal drug delivery, microfabrication, silicon microneedles, hollow microneedles, skin permeability, macromolecule delivery, nanoparticle delivery, intracellular delivery, diabetes mellitus
- MeSH terms
- Administration, Cutaneous, Animals, Biomedical Engineering, Blood Glucose, Cell Line, Diabetes Mellitus, Experimental, Equipment Design, Glass, Humans, Insulin, Male, Metals, Microinjections, Models, Biological, Polymers, Silicon, Syringes, Nanotechnology, Macromolecular Substances, Rats, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review