Observation of the noncovalent assembly and disassembly pathways of the chaperone complex MtGimC by mass spectrometry
Open accessThe DOI matches its Crossref record.
Abstract
We have analyzed a newly described archaeal GimC/prefoldin homologue, termed MtGimC, by using nanoflow electrospray coupled with time-of-flight MS. The molecular weight of the complex from Methanobacterium thermoautotrophicum corresponds to a well-defined hexamer of two α subunits and four β subunits. Dissociation of the complex within the gas phase reveals a quaternary arrangement of two central subunits, both α, and four peripheral β subunits. By constructing a thermally controlled nanoflow device, we have monitored the thermal stability of the complex by MS. The results of these experiments demonstrate that a significant proportion of the MtGimC hexamer remains intact under low-salt conditions at elevated temperatures. This finding is supported by data from CD spectroscopy, which show that at physiological salt concentrations, the complex remains stable at temperatures above 65°C. Mass spectrometric methods were developed to monitor in real time the assembly of the MtGimC hexamer from its component subunits. By using this methodology, the mass spectra recorded throughout the time course of the experiment showed the absence of any significantly populated intermediates, demonstrating that the assembly process is highly cooperative. Taken together, these data show that the complex is stable under the elevated temperatures that are appropriate for its hyperthermophile host and demonstrate that the assembly pathway leads exclusively to the hexamer, which is likely to be a structural unit in vivo .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Investigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583
The role of electron capture dissociation in biomolecular analysis
Cooper, H. J., Håkansson, K., & Marshall, A. G. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20014 · Cited by 514
Daniel, J. M., Friess, S. D., Rajagopalan, S., Wendt, S., & Zenobi, R. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00585-7 · Cited by 475
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Self-citationThe Role of Mass Spectrometry in Structure Elucidation of Dynamic Protein Complexes
Sharon, M., & Robinson, C. V. (2007) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.76.061005.090816 · Cited by 357
Self-citationStudies of biomolecular conformations and conformational dynamics by mass spectrometry
Kaltashov, I. A., & Eyles, S. J. (2002) · Mass Spectrometry Reviews · doi:10.1002/mas.10017 · Cited by 270
Konermann, L. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1739-3 · Cited by 243
Aquilina, J. A., Benesch, J. L. P., Bateman, O. A., Slingsby, C., & Robinson, C. V. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1932958100 · Cited by 243
Self-citationMartin-Benito, J. (2002) · The EMBO Journal · doi:10.1093/emboj/cdf640 · Cited by 217
“In the archaeal homolog, the two central tentacles belong to the two a-subunits and the four peripheral ones to the b-subunits (Fandrich et al., 2000; Siegert et al., 2000).”
BackgroundHorn, D. M., Breuker, K., Frank, A. J., & McLafferty, F. W. (2001) · Journal of the American Chemical Society · doi:10.1021/ja003143u · Cited by 178
Thermal Dissociation of Multimeric Protein Complexes by Using Nanoelectrospray Mass Spectrometry
Benesch, J. L. P., Sobott, F., & Robinson, C. V. (2003) · Analytical Chemistry · doi:10.1021/ac034132x · Cited by 170
Self-citationSun, J., Kitova, E. N., Wang, W., & Klassen, J. S. (2006) · Analytical Chemistry · doi:10.1021/ac0522005 · Cited by 160
Zhou, M., Lantz, C., Brown, K. A., Ge, Y., Paša-Tolić, L., Loo, J. A., & Lermyte, F. (2020) · Chemical Science · doi:10.1039/d0sc04392c · Cited by 146
Blackwell, A. E., Dodds, E. D., Bandarian, V., & Wysocki, V. H. (2011) · Analytical Chemistry · doi:10.1021/ac200452b · Cited by 84
Mass spectrometry: From plasma proteins to mitochondrial membranes
Robinson, C. V. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1820450116 · Cited by 53
“This led to opportunities to monitor changes in subunit composition, either through spontaneous exchange (11) or induced through thermal activation following construction of a thermally controlled nanoflow device (12, 13).”
BackgroundSelf-citation
Metadata
- Authors
- Fändrich, M., Tito, M. A., Leroux, M. R., Rostom, A. A., Hartl, F. U., Dobson, C. M., & Robinson, C. V.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2000-11-21
- Volume
- 97
- Issue
- 26
- Pages
- 14151-14155
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1970401341
- Cited by
- 100
- References
- 0
- FWCI
- 2.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.