A microfluidic model for single-cell capillary obstruction by Plasmodium falciparum -infected erythrocytes
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Severe malaria by Plasmodium falciparum is a potentially fatal disease, frequently unresponsive to even the most aggressive treatments. Host organ failure is associated with acquired rigidity of infected red blood cells and capillary blockage. In vitro techniques have played an important role in modeling cell deformability. Although, historically they have either been applied to bulk cell populations or to measure single physical parameters of individual cells. In this article, we demonstrate the unique abilities and benefits of elastomeric microchannels to characterize complex behaviors of single cells, under flow, in multicellular capillary blockages. Channels of 8-, 6-, 4-, and 2-μm widths were readily traversed by the 8 μm-wide, highly elastic, uninfected red blood cells, as well as by infected cells in the early ring stages. Trophozoite stages failed to freely traverse 2- to 4-μm channels; some that passed through the 4-μm channels emerged from constricted space with deformations whose shape-recovery could be observed in real time. In 2-μm channels, trophozoites mimicked “pitting,” a normal process in the body where spleen beds remove parasites without destroying the red cell. Schizont forms failed to traverse even 6-μm channels and rapidly formed a capillary blockage. Interestingly, individual uninfected red blood cells readily squeezed through the blockages formed by immobile schizonts in a 6-μm capillary. The last observation can explain the high parasitemia in a growing capillary blockage and the well known benefits of early blood transfusion in severe malaria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human Malaria Parasites in Continuous Culture
Trager, W., & Jensen, J. B. (1976) · Science · doi:10.1126/science.781840 · Cited by 7,844
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Self-citationSoft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
The pathogenic basis of malaria
Miller, L. H., Baruch, D. I., Marsh, K., & Doumbo, O. K. (2002) · Nature · doi:10.1038/415673a · Cited by 1,746
Miller, L. H., Good, M. F., & Milon, G. (1994) · Science · doi:10.1126/science.8009217 · Cited by 468
Crabb, B. S., Cooke, B. M., Reeder, J. C., Waller, R. F., Caruana, S. R., Davern, K. M., Wickham, M. E., Brown, G. V., Coppel, R. L., & Cowman, A. F. (1997) · Cell · doi:10.1016/s0092-8674(00)80207-x · Cited by 439
Fischer, T. M., Stöhr-Liesen, M., & Schmid-Schönbein, H. (1978) · Science · doi:10.1126/science.715448 · Cited by 427
Microfabrication in Biology and Medicine
Voldman, J., Gray, M. L., & Schmidt, M. A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.401 · Cited by 344
Plasmodium falciparum Maturation Abolishes Physiologic Red Cell Deformability
Cranston, H. A., Boylan, C. W., Carroll, G. L., Sutera, S. P., Williamson, J. R., Gluzman, I. Y., & Krogstad, D. J. (1984) · Science · doi:10.1126/science.6362007 · Cited by 301
Abnormal Blood Flow and Red Blood Cell Deformability in Severe Malaria
Dondorp, A. M., Kager, P. A., Vreeken, J., & White, N. J. (2000) · Parasitology Today · doi:10.1016/s0169-4758(00)01666-5 · Cited by 237
The malaria-infected red blood cell: Structural and functional changes
COOKE, B., MOHANDAS, N., & COPPEL, R. (2001) · Advances in Parasitology · doi:10.1016/s0065-308x(01)50029-9 · Cited by 222
[1] Structure and deformation properties of red blood cells: Concepts and quantitative methods
Evans, E. A. (1989) · Methods in Enzymology · doi:10.1016/s0076-6879(89)73003-2 · Cited by 196
Manipulation and flow of biological fluids in straight channels micromachined in silicon
Wilding, P., Pfahler, J., Bau, H. H., Zemel, J. N., & Kricka, L. J. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.1.43 · Cited by 176
Hayashi, M., Yamada, H., MITAMURA, T., Horii, T., Yamamoto, A., & Moriyama, Y. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.m003323200 · Cited by 122
Pitting Function of the Spleen in Malaria: Ultrastructural Observations
Schnitzer, B., Sodeman, T. C., Mead, M. L., & Contacos, P. G. (1972) · Science · doi:10.1126/science.177.4044.175 · Cited by 110
Miller, L. H., Chien, S., & Usami, S. (1972) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.1972.21.133 · Cited by 58
Fabrication of in Vitro Microvascular Blood Flow Systems by Photolithography
Cokelet, G. R., Soave, R. J., Pugh, G. O., & Rathbun, L. (1993) · Microvascular Research · doi:10.1006/mvre.1993.1062 · Cited by 54
A silicon micromachined device for use in blood cell deformability studies
Tracey, M. C., Greenaway, R. S., Das, A., Kaye, P. H., & Barnes, A. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.398635 · Cited by 42
Cited by
Biomechanics and biophysics of cancer cells☆
SURESH, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.04.002 · Cited by 1,284
“Such measurements have also been complemented with microfluidic assays capable of documenting movements of infected RBCs through constricted channels whose inner cross-sections are comparable to those encountered by RBCs circulating in small capillaries [72].”
BackgroundProperties and Applications of PDMS for Biomedical Engineering: A Review
Miranda, I., Souza, A., Sousa, P., Ribeiro, J., Castanheira, E. M. S., Lima, R., & Minas, G. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb13010002 · Cited by 824
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Shape and Biomechanical Characteristics of Human Red Blood Cells in Health and Disease
Diez-Silva, M., Dao, M., Han, J., Lim, C.-T., & Suresh, S. (2010) · MRS Bulletin · doi:10.1557/mrs2010.571 · Cited by 595
Metadata
- Authors
- Shelby, J. P., White, J., Ganesan, K., Rathod, P. K., & Chiu, D. T.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2003-11-24
- Volume
- 100
- Issue
- 25
- Pages
- 14618-14622
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2098708326
- Cited by
- 433
- References
- 19
- FWCI
- 11.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.