A microfluidic model for single-cell capillary obstruction by Plasmodium falciparum -infected erythrocytes
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Severe malaria by Plasmodium falciparum is a potentially fatal disease, frequently unresponsive to even the most aggressive treatments. Host organ failure is associated with acquired rigidity of infected red blood cells and capillary blockage. In vitro techniques have played an important role in modeling cell deformability. Although, historically they have either been applied to bulk cell populations or to measure single physical parameters of individual cells. In this article, we demonstrate the unique abilities and benefits of elastomeric microchannels to characterize complex behaviors of single cells, under flow, in multicellular capillary blockages. Channels of 8-, 6-, 4-, and 2-μm widths were readily traversed by the 8 μm-wide, highly elastic, uninfected red blood cells, as well as by infected cells in the early ring stages. Trophozoite stages failed to freely traverse 2- to 4-μm channels; some that passed through the 4-μm channels emerged from constricted space with deformations whose shape-recovery could be observed in real time. In 2-μm channels, trophozoites mimicked “pitting,” a normal process in the body where spleen beds remove parasites without destroying the red cell. Schizont forms failed to traverse even 6-μm channels and rapidly formed a capillary blockage. Interestingly, individual uninfected red blood cells readily squeezed through the blockages formed by immobile schizonts in a 6-μm capillary. The last observation can explain the high parasitemia in a growing capillary blockage and the well known benefits of early blood transfusion in severe malaria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human Malaria Parasites in Continuous Culture
Trager, W., & Jensen, J. B. (1976) · Science · doi:10.1126/science.781840 · Cited by 7,844
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Self-citationSoft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
The pathogenic basis of malaria
Miller, L. H., Baruch, D. I., Marsh, K., & Doumbo, O. K. (2002) · Nature · doi:10.1038/415673a · Cited by 1,746
Miller, L. H., Good, M. F., & Milon, G. (1994) · Science · doi:10.1126/science.8009217 · Cited by 468
Crabb, B. S., Cooke, B. M., Reeder, J. C., Waller, R. F., Caruana, S. R., Davern, K. M., Wickham, M. E., Brown, G. V., Coppel, R. L., & Cowman, A. F. (1997) · Cell · doi:10.1016/s0092-8674(00)80207-x · Cited by 439
Fischer, T. M., Stöhr-Liesen, M., & Schmid-Schönbein, H. (1978) · Science · doi:10.1126/science.715448 · Cited by 427
Microfabrication in Biology and Medicine
Voldman, J., Gray, M. L., & Schmidt, M. A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.401 · Cited by 344
Plasmodium falciparum Maturation Abolishes Physiologic Red Cell Deformability
Cranston, H. A., Boylan, C. W., Carroll, G. L., Sutera, S. P., Williamson, J. R., Gluzman, I. Y., & Krogstad, D. J. (1984) · Science · doi:10.1126/science.6362007 · Cited by 301
Cited by
Biomechanics and biophysics of cancer cells☆
SURESH, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.04.002 · Cited by 1,284
“Such measurements have also been complemented with microfluidic assays capable of documenting movements of infected RBCs through constricted channels whose inner cross-sections are comparable to those encountered by RBCs circulating in small capillaries [72].”
BackgroundProperties and Applications of PDMS for Biomedical Engineering: A Review
Miranda, I., Souza, A., Sousa, P., Ribeiro, J., Castanheira, E. M. S., Lima, R., & Minas, G. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb13010002 · Cited by 824
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Shape and Biomechanical Characteristics of Human Red Blood Cells in Health and Disease
Diez-Silva, M., Dao, M., Han, J., Lim, C.-T., & Suresh, S. (2010) · MRS Bulletin · doi:10.1557/mrs2010.571 · Cited by 595
Shape transitions of fluid vesicles and red blood cells in capillary flows
Noguchi, H., & Gompper, G. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504243102 · Cited by 580
Engineered In Vitro Disease Models
Benam, K. H., Dauth, S., Hassell, B., Herland, A., Jain, A., Jang, K.-J., Karalis, K., Kim, H. J., MacQueen, L., Mahmoodian, R., et al. (2015) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathol-012414-040418 · Cited by 554
Force Microscopy of Nonadherent Cells: A Comparison of Leukemia Cell Deformability
Rosenbluth, M. J., Lam, W. A., & Fletcher, D. A. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.067496 · Cited by 532
Disposable Microfluidic Devices: Fabrication, Function, and Application
Fiorini, G. S., & Chiu, D. T. (2005) · BioTechniques · doi:10.2144/05383rv02 · Cited by 487
Self-citationBiomechanics approaches to studying human diseases
Lee, G. Y. H., & Lim, C. T. (2007) · Trends in Biotechnology · doi:10.1016/j.tibtech.2007.01.005 · Cited by 485
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Biomechanics and biophysics of cancer cells☆
SURESH, S. (2007) · Acta Materialia · doi:10.1016/j.actamat.2007.04.022 · Cited by 467
Microengineered Platforms for Cell Mechanobiology
Kim, D.-H., Wong, P. K., Park, J., Levchenko, A., & Sun, Y. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124915 · Cited by 411
Point-of-care microfluidic devices for pathogen detection
Nasseri, B., Soleimani, N., Rabiee, N., Kalbasi, A., Karimi, M., & Hamblin, M. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.050 · Cited by 382
Biomechanical properties of red blood cells in health and disease towards microfluidics
Tomaiuolo, G. (2014) · Biomicrofluidics · doi:10.1063/1.4895755 · Cited by 368
Microdevice for the isolation and enumeration of cancer cells from blood
Tan, S. J., Yobas, L., Lee, G. Y. H., Ong, C. N., & Lim, C. T. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9305-9 · Cited by 362
Nano/Microfluidics for diagnosis of infectious diseases in developing countries
Lee, W. G., Kim, Y.-G., Chung, B. G., Demirci, U., & Khademhosseini, A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.016 · Cited by 357
Hou, H. W., Bhagat, A. A. S., Lin Chong, A. G., Mao, P., Wei Tan, K. S., Han, J., & Lim, C. T. (2010) · Lab on a Chip · doi:10.1039/c003873c · Cited by 300
Tsai, M., Kita, A., Leach, J., Rounsevell, R., Huang, J. N., Moake, J., Ware, R. E., Fletcher, D. A., & Lam, W. A. (2012) · Journal of Clinical Investigation · doi:10.1172/jci58753 · Cited by 297
Multiscale modeling of blood flow: from single cells to blood rheology
Fedosov, D. A., Noguchi, H., & Gompper, G. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0497-9 · Cited by 277
Recent advances in microfluidic techniques for single-cell biophysical characterization
Zheng, Y., Nguyen, J., Wei, Y., & Sun, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50355k · Cited by 267
Carl, P., & Schillers, H. (2008) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-008-0524-3 · Cited by 231
“An increase of cell elasticity was shown for endothelial cells under high sodium conditions [48] and hyperaldosteronism [24, 45], for chondrocytes in arthritis [62], for airway smooth muscle cells in bronchial asthma [2], for erythrocytes in malaria [ 59 ], for cardiac muscle in ischemia [19], and several other condit…”
BackgroundReview on Cell Mechanics: Experimental and Modeling Approaches
Rodriguez, M. L., McGarry, P. J., & Sniadecki, N. J. (2013) · Applied Mechanics Reviews · doi:10.1115/1.4025355 · Cited by 218
“…on the effect of hydrodynamic stretching on single cells [207] [316], cell movement through fluid and/or solid environments of different geometries [317] [318] [319] [320] [321], the effect of multiple different applied forces on adherent cells [322] [323], and the chemotactic movement of cells…”
BackgroundTan, S. J., Lakshmi, R. L., Chen, P., Lim, W.-T., Yobas, L., & Lim, C. T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.054 · Cited by 203
The dynamic behavior of chemically “stiffened” red blood cells in microchannel flows
Forsyth, A. M., Wan, J., Ristenpart, W. D., & Stone, H. A. (2010) · Microvascular Research · doi:10.1016/j.mvr.2010.03.008 · Cited by 172
A circular cross-section PDMS microfluidics system for replication of cardiovascular flow conditions
Fiddes, L. K., Raz, N., Srigunapalan, S., Tumarkan, E., Simmons, C. A., Wheeler, A. R., & Kumacheva, E. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.082 · Cited by 170
Polymer-Based Microfluidic Devices for Pharmacy, Biology and Tissue Engineering
Alrifaiy, A., Lindahl, O. A., & Ramser, K. (2012) · Polymers · doi:10.3390/polym4031349 · Cited by 161
“Viable cells could pass through the narrow channels while the infected, mechanically rigid cells could not [372,373].”
BackgroundMethodChen, J., Xue, C., Zhao, Y., Chen, D., Wu, M.-H., & Wang, J. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16059804 · Cited by 160
Forced transport of deformable containers through narrow constrictions
Kusters, R., van der Heijden, T., Kaoui, B., Harting, J., & Storm, C. (2014) · Physical Review E · doi:10.1103/physreve.90.033006 · Cited by 40
Metadata
- Authors
- Shelby, J. P., White, J., Ganesan, K., Rathod, P. K., & Chiu, D. T.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2003-11-24
- Volume
- 100
- Issue
- 25
- Pages
- 14618-14622
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2098708326
- Cited by
- 433
- References
- 19
- FWCI
- 11.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.