Top-down mass spectrometry of a 29-kDa protein for characterization of any posttranslational modification to within one residue
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A mass difference between the measured molecular weight of a protein and that of its DNA-predicted sequence indicates sequence errors and/or posttranslational modifications. In the top-down mass spectrometry approach, the measured molecular ion is dissociated, and these fragment masses are matched against those predicted from the protein sequence to restrict the locations of the errors/modifications. The proportion of the ion's interresidue bonds that are cleaved determines the specificity of such locations; previously, ubiquitin (76 residues) was the largest for which all such bonds were dissociated. Now, cleavages are achieved for carbonic anhydrase at 250 of the 258 interresidue locations. Cleavages of three spectra would define posttranslational modifications at 235 residues to within one residue. For 24 of the 34 possible phosphorylation sites, the cleavages of one spectrum would delineate exactly all −PO 3 H substitutions. This result has been achieved with electron-capture dissociation by minimizing the further cleavage of primary product ions and by denaturing the tertiary noncovalent bonding of the molecular ions under a variety of conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Self-citationAutomated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Self-citation
Cited by
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Proteomic analysis of post-translational modifications
Mann, M., & Jensen, O. N. (2003) · Nature Biotechnology · doi:10.1038/nbt0303-255 · Cited by 2,134
The abc's (and xyz's) of peptide sequencing
Steen, H., & Mann, M. (2004) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1468 · Cited by 1,150
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Nørregaard Jensen, O. (2004) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.12.009 · Cited by 624
Orbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
The role of electron capture dissociation in biomolecular analysis
Cooper, H. J., Håkansson, K., & Marshall, A. G. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20014 · Cited by 514
Interpreting the protein language using proteomics
Jensen, O. N. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1939 · Cited by 502
Proteomics by FTICR mass spectrometry: Top down and bottom up
Bogdanov, B., & Smith, R. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20015 · Cited by 447
Applying mass spectrometry-based proteomics to genetics, genomics and network biology
Gstaiger, M., & Aebersold, R. (2009) · Nature Reviews Genetics · doi:10.1038/nrg2633 · Cited by 442
Reactions of polypeptide ions with electrons in the gas phase
Zubarev, R. A. (2003) · Mass Spectrometry Reviews · doi:10.1002/mas.10042 · Cited by 431
Protein identification using sequential ion/ion reactions and tandem mass spectrometry
Coon, J. J., Ueberheide, B., Syka, J. E. P., Dryhurst, D. D., Ausio, J., Shabanowitz, J., & Hunt, D. F. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503189102 · Cited by 373
Mechanism of Charging and Supercharging Molecules in Electrospray Ionization
Iavarone, A. T., & Williams, E. R. (2003) · Journal of the American Chemical Society · doi:10.1021/ja021202t · Cited by 324
Terminology of bioanalytical methods (IUPAC Recommendations 2018)
Labuda, J., Bowater, R. P., Fojta, M., Gauglitz, G., Glatz, Z., Hapala, I., Havliš, J., Kilar, F., Kilar, A., Malinovská, L., et al. (2018) · Pure and Applied Chemistry · doi:10.1515/pac-2016-1120 · Cited by 287
‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285
The diverse and expanding role of mass spectrometry in structural and molecular biology
Lössl, P., van de Waterbeemd, M., & Heck, A. J. (2016) · The EMBO Journal · doi:10.15252/embj.201694818 · Cited by 222
“This breakthrough was achieved on FTICR mass spectrometers mainly due to the invention of ECD fragmentation (Horn et al , 2000; Sze et al , 2002).”
Tackling the phosphoproteome: tools and strategies
Kalume, D. E., Molina, H., & Pandey, A. (2003) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00009-1 · Cited by 206
Pan, J., Han, J., Borchers, C. H., & Konermann, L. (2009) · Journal of the American Chemical Society · doi:10.1021/ja904379w · Cited by 201
Macek, B., Waanders, L. F., Olsen, J. V., & Mann, M. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500042-mcp200 · Cited by 197
“bonds in a protein (28); however, it suffers from relatively low”
BackgroundZhang, J., Guy, M. J., Norman, H. S., Chen, Y.-C., Xu, Q., Dong, X., Guner, H., Wang, S., Kohmoto, T., Young, K. H., et al. (2011) · Journal of Proteome Research · doi:10.1021/pr200258m · Cited by 194
Self-citationTop‐down MS, a powerful complement to the high capabilities of proteolysis proteomics
McLafferty, F. W., Breuker, K., Jin, M., Han, X., Infusini, G., Jiang, H., Kong, X., & Begley, T. P. (2007) · The FEBS Journal · doi:10.1111/j.1742-4658.2007.06147.x · Cited by 186
Self-citationDeconvolution and Database Search of Complex Tandem Mass Spectra of Intact Proteins
Liu, X., Inbar, Y., Dorrestein, P. C., Wynne, C., Edwards, N., Souda, P., Whitelegge, J. P., Bafna, V., & Pevzner, P. A. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.002766 · Cited by 170
Dorrestein, P. C., Bumpus, S. B., Calderone, C. T., Garneau-Tsodikova, S., Aron, Z. D., Straight, P. D., Kolter, R., Walsh, C. T., & Kelleher, N. L. (2006) · Biochemistry · doi:10.1021/bi061169d · Cited by 165
“Tandem mass spectrometry on intact proteins is also known as the “Top Down” approach (7), and 4) finally, we show that the method is readily adapted to benchtop mass spectrometers making it useful to researchers that do not have access to high end MS instrumentation.”
Proteolytic elimination of N-myristoyl modifications by the Shigella virulence factor IpaJ
Burnaevskiy, N., Fox, T. G., Plymire, D. A., Ertelt, J. M., Weigele, B. A., Selyunin, A. S., Way, S. S., Patrie, S. M., & Alto, N. M. (2013) · Nature · doi:10.1038/nature12004 · Cited by 159
Venomics: unravelling the complexity of animal venoms with mass spectrometry
Escoubas, P., Quinton, L., & Nicholson, G. M. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1389 · Cited by 158
Protein Identification Using Top-Down Spectra
Liu, X., Sirotkin, Y., Shen, Y., Anderson, G., Tsai, Y. S., Ting, Y. S., Goodlett, D. R., Smith, R. D., Bafna, V., & Pevzner, P. A. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.008524 · Cited by 153
“Our analysis is broken into four increasingly more difficult cases: (1) complete nonshift alignments; (2) prefix, suffix, and internal nonshift alignments; (3) complete shift alignments; and (4) prefix, suffix, and internal shift alignments.”
BackgroundMethodPeng, Y., Gregorich, Z. R., Valeja, S. G., Zhang, H., Cai, W., Chen, Y.-C., Guner, H., Chen, A. J., Schwahn, D. J., Hacker, T. A., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.040675 · Cited by 107
Self-citationAugmented Phosphorylation of Cardiac Troponin I in Hypertensive Heart Failure
Dong, X., Sumandea, C. A., Chen, Y.-C., Garcia-Cazarin, M. L., Zhang, J., Balke, C. W., Sumandea, M. P., & Ge, Y. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.m111.293258 · Cited by 99
Self-citationTucholski, T., Knott, S. J., Chen, B., Pistono, P., Lin, Z., & Ge, Y. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04082 · Cited by 49
Self-citationRiley, N. M., Sikora, J. W., Seckler, H. S., Greer, J. B., Fellers, R. T., LeDuc, R. D., Westphall, M. S., Thomas, P. M., Kelleher, N. L., & Coon, J. J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01638 · Cited by 43
Metadata
- Authors
- Sze, S. K., Ge, Y., Oh, H., & McLafferty, F. W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2002-02-12
- Volume
- 99
- Issue
- 4
- Pages
- 1774-1779
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2014578458
- Cited by
- 250
- References
- 2
- FWCI
- 10.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.