The DOI matches its Crossref record.
Fluorescence energy transfer in the rapid-diffusion limit
Open accessAbstract
Energy transfer is enhanced by translational diffusion of the donor and acceptor [Steinberg, I. Z. & Katchalski, E. (1968) J. Chem. Phys. 48, 2404-2410]. The effect of diffusion on energy transfer depends on D τ 0 / s 2 , in which D is the sum of the diffusion coefficients of the donor and acceptor, τ 0 is the lifetime of the donor in the absence of transfer, and s is the mean distance between donors and acceptors. In most previous studies, D τ 0 / s 2 ≪ 1, corresponding to the static limit. We report here steady-state and kinetic fluorescence experiments showing that D τ 0 / s 2 ≫ 1, the rapid-diffusion limit, can be attained by using Tb 3+ chelated to dipicolinate as a long-lived energy donor (τ 0 = 2.2 msec). The concentration of rhodamine B, the energy acceptor, resulting in 50% transfer was 0.67 μM, which is three orders of magnitude less than the concentration giving 50% transfer in the static limit. The dependence of the transfer efficiency on diffusion coefficients varying from 5 × 10 -11 to 1.5 × 10 -4 cm 2 /sec, spanning the range from the static limit to the rapid-diffusion limit, is in excellent agreement with theory. It is evident that energy donors with millisecond or longer excited state lifetimes can be used to probe translational motions in membranes and other assemblies. Energy transfer in the rapid diffusion limit is sensitive to the distance of closest approach ( a ) of the donor and acceptor. For a Tb·(DPA) 3 chelate trapped inside the aqueous space of a membrane vesicle containing eosin phosphatidylethanolamine, a = 10 Å. The transverse location of chromophores in model membranes and biological membranes can be determined by this technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wilschut, J., Duzgunes, N., Fraley, R., & Papahadjopoulos, D. (1980) · Biochemistry · doi:10.1021/bi00567a011 · Cited by 490
Low power, non-coherent sensitized photon up-conversion: modelling and perspectives
Monguzzi, A., Tubino, R., Hoseinkhani, S., Campione, M., & Meinardi, F. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp23900k · Cited by 472
Rare earth cryptates and homogeneous fluoroimmunoassays with human sera
Mathis, G. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.9.1953 · Cited by 392
Mathis, G. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.9.1391 · Cited by 339
Stoichiometry of a Ligand-gated Ion Channel Determined by Fluorescence Energy Transfer
Farrar, S. J., Whiting, P. J., Bonnert, T. P., & McKernan, R. M. (1999) · Journal of Biological Chemistry · doi:10.1074/jbc.274.15.10100 · Cited by 269
Metadata
- Authors
- Thomas, D. D., Carlsen, W. F., & Stryer, L.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1978-12
- Volume
- 75
- Issue
- 12
- Pages
- 5746-5750
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1990630388
- Cited by
- 168
- References
- 0
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence energy transfer in the rapid-diffusion limit. https://app.cochat.ai/papers/10.1073/pnas.75.12.5746
- The paper
- Thomas, D. D., Carlsen, W. F., & Stryer, L. (1978). Fluorescence energy transfer in the rapid-diffusion limit. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.75.12.5746
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.