Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 392

The DOI matches its Crossref record.

Rare earth cryptates and homogeneous fluoroimmunoassays with human sera

Mathis, G·1993·Clinical Chemistry

Abstract

The rare earth cryptates are used as long-lived fluorescent labels. They are formed by inclusion of a europium ion in the intramolecular cavity of a macropolycyclic ligand containing bipyridine groups as light absorbers. The use of fluoride ions in the measuring medium allows a total shielding of the label fluorescence. Here, I have established the conditions under which the signal of these cryptates can be amplified through the use of nonradiative energy transfer, and applied these conditions to homogeneous immunoassays by using allophycocyanin as the acceptor. Because only a low proportion of the cryptate label is involved in the transfer amplification, and because allophycocyanin emission occurs between the europium emission lines, time-resolved measurement of europium and allophycocyanin emission allows real-time correction of the optical properties of the assay medium. These features have allowed the development of a rapid homogeneous immunoassay of prolactin that can detect as little as 0.3 microgram/L (3rd International Standard 84/500).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/clinchem/39.9.1953

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 392

Metadata

Authors
Mathis, G.
Venue
Clinical Chemistry
Published
1993-09-01
Volume
39
Issue
9
Pages
1953-1959
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2155645504
Cited by
392
References
0
FWCI
8.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rare earth cryptates and homogeneous fluoroimmunoassays with human sera. https://app.cochat.ai/papers/10.1093/clinchem/39.9.1953
The paper
Mathis, G. (1993). Rare earth cryptates and homogeneous fluoroimmunoassays with human sera. Clinical Chemistry. https://doi.org/10.1093/clinchem/39.9.1953

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.