NMR chemical shift imaging in three dimensions.
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A method for obtaining the three-dimensional distribution of chemical shifts in a spatially inhomogeneous sample using Fourier transform NMR is presented. The method uses a sequence of pulsed field gradients to measure the Fourier transform of the desired distribution on a rectangular grid in (k,t) space. Simple Fourier inversion then recovers the original distribution. An estimated signal/noise ratio of 20 in 10 min is obtained for an "image" of the distribution of a 10 mM phosphorylated metabolite in the human head at a field of 20 kG with 2-cm resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mapping of metabolites in whole animals by 31P NMR using surface coils
Ackerman, J. J. H., Grove, T. H., Wong, G. G., Gadian, D. G., & Radda, G. K. (1980) · Nature · doi:10.1038/283167a0 · Cited by 1,005
Spin warp NMR imaging and applications to human whole-body imaging
Edelstein, W. A., Hutchison, J. M. S., Johnson, G., & Redpath, T. (1980) · Physics in Medicine & Biology · doi:10.1088/0031-9155/25/4/017 · Cited by 803
Cited by
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Simultaneousin vivo spectral editing and water suppression
Mescher, M., Merkle, H., Kirsch, J., Garwood, M., & Gruetter, R. (1998) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199810)11:6<266::aid-nbm530>3.0.co;2-j · Cited by 1,015
Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging
Haase, A. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130109 · Cited by 693
Studies of human tumors by MRS: A review
Negendank, W. (1992) · NMR in Biomedicine · doi:10.1002/nbm.1940050518 · Cited by 660
Golman, K., in ‘t Zandt, R., & Thaning, M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0601319103 · Cited by 659
Dixon techniques for water and fat imaging
Ma, J. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21492 · Cited by 610
Simultaneous spatial and spectral selective excitation
Meyer, C. H., Pauly, J. M., Macovskiand, A., & Nishimura, D. G. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150211 · Cited by 498
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Magnetic resonance spectroscopy of the human brain
Ross, B., & Bluml, S. (2001) · The Anatomical Record · doi:10.1002/ar.1058 · Cited by 411
1H MR Spectroscopy of the Brain: Absolute Quantification of Metabolites
Jansen, J. F. A., Backes, W. H., Nicolay, K., & Kooi, M. E. (2006) · Radiology · doi:10.1148/radiol.2402050314 · Cited by 405
Imaging of Brain Tumors: MR Spectroscopy and Metabolic Imaging
Horská, A., & Barker, P. B. (2010) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2010.04.003 · Cited by 356
Weiss, R. G., Bottomley, P. A., Hardy, C. J., & Gerstenblith, G. (1990) · New England Journal of Medicine · doi:10.1056/nejm199012063232304 · Cited by 353
Multidimensional X-Space Magnetic Particle Imaging
Goodwill, P. W., & Conolly, S. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2125982 · Cited by 319
Scheenen, T. W. J., Klomp, D. W. J., Wijnen, J. P., & Heerschap, A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21302 · Cited by 293
Theory and application of static field inhomogeneity effects in gradient‐echo imaging
Reichenbach, J. R., Venkatesan, R., Yablonskiy, D. A., Thompson, M. R., Lai, S., & Haacke, E. M. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070203 · Cited by 285
Single-scan multidimensional magnetic resonance
Tal, A., & Frydman, L. (2010) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2010.04.001 · Cited by 277
Garnett, M. R. (2000) · Brain · doi:10.1093/brain/123.10.2046 · Cited by 275
In vivo magnetic resonance spectroscopy: basic methodology and clinical applications
van der Graaf, M. (2010) · European Biophysics Journal · doi:10.1007/s00249-009-0517-y · Cited by 275
Quantitative proton MR spectroscopic imaging of the human brain
Soher, B. J., van Zijl, P. C. M., Duyn, J. H., & Barker, P. B. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350313 · Cited by 271
Wozniak, J. R., & Lim, K. O. (2006) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2006.06.003 · Cited by 261
In Vivo Magnetic Resonance Spectroscopy in Cancer
Gillies, R. J., & Morse, D. L. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100411 · Cited by 261
Principles and Features of Single-Scan Two-Dimensional NMR Spectroscopy
Frydman, L., Lupulescu, A., & Scherf, T. (2003) · Journal of the American Chemical Society · doi:10.1021/ja030055b · Cited by 259
MR spectroscopic imaging: Principles and recent advances
Posse, S., Otazo, R., Dager, S. R., & Alger, J. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23945 · Cited by 211
“slice (1) H MRSI of the human brain at 7 T using dynamic B(0)”
BackgroundMethodInfluentialElas, M., Williams, B. B., Parasca, A., Mailer, C., Pelizzari, C. A., Lewis, M. A., River, J. N., Karczmar, G. S., Barth, E. D., & Halpern, H. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10408 · Cited by 194
“Data were acquired by conventional spectroscopic imaging in which phase-encoding gradients were applied, and the water signal was then detected in the absence of the applied gradients (21,22).”
MethodImaging at ultrahigh magnetic fields: History, challenges, and solutions
Uğurbil, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.007 · Cited by 173
“, (Ackerman et al., 1980b; Gordon et al., 1980; Brown et al., 1982; Maudsley et al., 1983; Garwood et al., 1984)) and experiments with whole animals (e.”
BackgroundBroadband proton decoupling in human 31p NMR spectroscopy
Luyten, P. R., Bruntink, G., Sloff, F. M., Vermeulen, J. W. A. H., Van Der Heijden, J. I., Den Hollander, J. A., & Heerschap, A. (1989) · NMR in Biomedicine · doi:10.1002/nbm.1940010405 · Cited by 168
Charles, H. C., Lazeyras, F., Krishnan, K. R. R., Boyko, O. B., Payne, M., & Moore, D. (1994) · Progress in Neuro-Psychopharmacology and Biological Psychiatry · doi:10.1016/0278-5846(94)90115-5 · Cited by 145
Metadata
- Authors
- Brown, T. R., Kincaid, B. M., & Ugurbil, K.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1982-06
- Volume
- 79
- Issue
- 11
- Pages
- 3523-3526
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2020961426
- Cited by
- 1,039
- References
- 2
- FWCI
- 7.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.