Ca2+- and K+-dependent communication between central nervous system myelinated axons and oligodendrocytes revealed by voltage-sensitive dyes.
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The interactions between myelinated axons and surrounding glia cells, in rat optic nerve, were investigated by optical recording with voltage-sensitive dyes. Electrical stimulation of the nerve evoked an optical signal revealing two clearly distinct components: a fast propagating component, corresponding to the compound action potential, and a prominent slow component. Several lines of evidence suggest that part of the slow component originated from depolarization of the oligodendrocytes by potassium accumulation in the paranodal or internodal region. In addition, the experiments suggest that in this preparation axons also have voltage-dependent Ca2+ channels, and a Ca2+-dependent K+ conductance involved in the depolarization of oligodendrocytes. Thus, axons and oligodendrocytes communicate in an intimate, ionically-mediated fashion, and oligodendrocytes may play an important functional role beyond that of providing the myelin sheath.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light scattering and birefringence changes during nerve activity
COHEN, L. B., KEYNES, R. D., & HILLE, B. (1968) · Nature · doi:10.1038/218438a0 · Cited by 479
Electron microscopic autoradiographic studies of gliogenesis in rat optic nerve. II. Time of origin
Skoff, R. P., Price, D. L., & Stocks, A. (1976) · Journal of Comparative Neurology · doi:10.1002/cne.901690304 · Cited by 312
Rat optic nerve: electrophysiological, pharmacological and anatomical studies during development
Foster, R. E., Connors, B. W., & Waxman, S. G. (1982) · Developmental Brain Research · doi:10.1016/0165-3806(82)90005-0 · Cited by 278
Fishman, M. C., & Spector, I. (1981) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.78.8.5245 · Cited by 135
Cited by
White matter in learning, cognition, and psychiatric disorders
Fields, R. D. (2008) · Trends in Neurosciences · doi:10.1016/j.tins.2008.04.001 · Cited by 1,337
“In the 1980s, studies using voltage-sensitive and calcium-sensitive fluorescent indicators revealed responses in the myelin sheath of CNS axons firing action potentials [ 90 ] and in paranodal loops of myelinating Schwann cells in the peripheral nervous system [91].”
Myelin basic protein: a multifunctional protein
Boggs, J. M. (2006) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-006-6094-7 · Cited by 687
VSDI: a new era in functional imaging of cortical dynamics
Grinvald, A., & Hildesheim, R. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1536 · Cited by 618
Self-citationEfimov, I. R., Nikolski, V. P., & Salama, G. (2004) · Circulation Research · doi:10.1161/01.res.0000130529.18016.35 · Cited by 390
Imaging cell volume changes and neuronal excitation in the hippocampal slice
Andrew, R. D., & Macvicar, B. A. (1994) · Neuroscience · doi:10.1016/0306-4522(94)90372-7 · Cited by 304
Optical Imaging of Voltage and Calcium in Cardiac Cells & Tissues
Herron, T. J., Lee, P., & Jalife, J. (2012) · Circulation Research · doi:10.1161/circresaha.111.247494 · Cited by 289
Llinás, R. R., Leznik, E., & Urbano, F. J. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.012604899 · Cited by 264
In-vivo Optical Imaging of Cortical Architecture and Dynamics
Grinvald, A., Shoham, D., Shmuel, A., Glaser, D., Vanzetta, I., Shtoyerman, E., Slovin, H., Wijnbergen, C., Hildesheim, R., & Arieli, A. (1999) · Modern Techniques in Neuroscience Research · doi:10.1007/978-3-642-58552-4_34 · Cited by 219
Self-citationUse of voltage-sensitive dyes and optical recordings in the central nervous system
Ebner, T. J., & Chen, G. (1995) · Progress in Neurobiology · doi:10.1016/0301-0082(95)00010-s · Cited by 210
“Different dyes may preferentially stain different neuronal membranes (Lev-Ram and Grinvald , 1986; Konnerth et al., 1987).”
BackgroundNashmi, R. (2001) · Brain Research Reviews · doi:10.1016/s0165-0173(01)00134-5 · Cited by 186
Calcium stores in neurons and glia
Kostyuk, P., & Verkhratsky, A. (1994) · Neuroscience · doi:10.1016/0306-4522(94)90537-1 · Cited by 182
Voltage-sensitive dye imaging: Technique review and models
Chemla, S., & Chavane, F. (2010) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2009.11.009 · Cited by 180
Role of Gap Junctions in Synchronized Neuronal Oscillations in the Inferior Olive
Leznik, E., & Llinás, R. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00353.2005 · Cited by 179
“In brief, the recordings were detrended to compensate for bleaching of the dye and slow responses from glia cells (Konnerth et al. 1987; Lev-Ram and Grinvald 1986).”
Finkbeiner, S. M. (1993) · Glia · doi:10.1002/glia.440090202 · Cited by 175
Konnerth, A., Obaid, A. L., & Salzberg, B. M. (1987) · The Journal of Physiology · doi:10.1113/jphysiol.1987.sp016848 · Cited by 160
Metadata
- Authors
- Lev-Ram, V, & Grinvald, A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1986-09
- Volume
- 83
- Issue
- 17
- Pages
- 6651-6655
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1993503444
- Cited by
- 92
- References
- 4
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.