The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Attachment of a 40-base-pair G + C-rich sequence (GC-clamp) to genomic DNA fragments by the polymerase chain reaction results in improved detection of single-base changes.
Open accessAbstract
Denaturing gradient gel electrophoresis (DGGE) can be used to distinguish two DNA molecules that differ by as little as a single-base substitution. This method detects approximately 50% of all possible single-base changes in DNA fragments ranging from 50 to approximately 1000 base pairs. To increase the number of single-base changes that can be distinguished by DGGE, we used the polymerase chain reaction to attach a 40-base-pair G + C-rich sequence, designated a GC-clamp, to one end of amplified DNA fragments that encompass regions of the mouse and human beta-globin genes. We show that this GC-clamp allows the detection of mutations, including the hemoglobin sickle (HbS) and hemoglobin C (HbC) mutations within the human beta-globin gene, that were previously indistinguishable by DGGE. In addition to providing an easy way to attach a GC-clamp to genomic DNA fragments, the polymerase chain reaction technique greatly increases the sensitivity of DGGE. With this approach, DNA fragments derived from less than 5 ng of human genomic DNA can be detected by ethidium bromide staining of the gel, obviating the need for radioactive probes. These improvements extend the applicability of DGGE for the detection of polymorphisms and mutations in genomic and cloned DNA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Primer-Directed Enzymatic Amplification of DNA with a Thermostable DNA Polymerase
Saiki, R. K., Gelfand, D. H., Stoffel, S., Scharf, S. J., Higuchi, R., Horn, G. T., Mullis, K. B., & Erlich, H. A. (1988) · Science · doi:10.1126/science.2448875 · Cited by 17,719
Saiki, R. K., Scharf, S., Faloona, F., Mullis, K. B., Horn, G. T., Erlich, H. A., & Arnheim, N. (1985) · Science · doi:10.1126/science.2999980 · Cited by 8,956
Cited by
PCR-DGGE fingerprinting: novel strategies for detection of microbes in food
Ercolini, D. (2004) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2003.11.006 · Cited by 624
Genetic linkage of familial open angle glaucoma to chromosome 1q21–q31
Sheffield, V. C., Stone, E. M., Alward, W. L. M., Drack, A. V., Johnson, A. T., Streb, L. M., & Nichols, B. E. (1993) · Nature Genetics · doi:10.1038/ng0593-47 · Cited by 438
Self-citationThompson, L., Chang, B., & Barsky, S. H. (1996) · The American Journal of Surgical Pathology · doi:10.1097/00000478-199603000-00003 · Cited by 365
The rapid detection of unknown mutations in nucleic acids
Grompe, M. (1993) · Nature Genetics · doi:10.1038/ng1093-111 · Cited by 310
Drosophila Ecdysone Receptor Mutations Reveal Functional Differences among Receptor Isoforms
Bender, M., Imam, F. B., Talbot, W. S., Ganetzky, B., & Hogness, D. S. (1997) · Cell · doi:10.1016/s0092-8674(00)80466-3 · Cited by 280
Metadata
- Authors
- Sheffield, V. C., Cox, D. R., Lerman, L. S., & Myers, R. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1989-01
- Volume
- 86
- Issue
- 1
- Pages
- 232-236
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2103170384
- Cited by
- 1,269
- References
- 2
- FWCI
- 47.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Attachment of a 40-base-pair G + C-rich sequence (GC-clamp) to genomic DNA fragments by the polymerase chain reaction results in improved detection of single-base changes. https://app.cochat.ai/papers/10.1073/pnas.86.1.232
- The paper
- Sheffield, V. C., Cox, D. R., Lerman, L. S., & Myers, R. M. (1989). Attachment of a 40-base-pair G + C-rich sequence (GC-clamp) to genomic DNA fragments by the polymerase chain reaction results in improved detection of single-base changes. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.86.1.232
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.