The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Open accessAbstract
Paramagnetic deoxyhemoglobin in venous blood is a naturally occurring contrast agent for magnetic resonance imaging (MRI). By accentuating the effects of this agent through the use of gradient-echo techniques in high fields, we demonstrate in vivo images of brain microvasculature with image contrast reflecting the blood oxygen level. This blood oxygenation level-dependent (BOLD) contrast follows blood oxygen changes induced by anesthetics, by insulin-induced hypoglycemia, and by inhaled gas mixtures that alter metabolic demand or blood flow. The results suggest that BOLD contrast can be used to provide in vivo real-time maps of blood oxygenation in the brain under normal physiological conditions. BOLD contrast adds an additional feature to magnetic resonance imaging and complements other techniques that are attempting to provide positron emission tomography-like measurements related to regional neural activity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In conventional fMRI, the BOLD response is elicited by neural activity, which drives flow of oxygen-rich blood (27, 28)”
From Coupled electrophysiological, hemodynamic, and cerebrospinal fluid oscillations in human sleep (2019) · cites this paper as [27]
In the citing paper
“The most widely used fMRI signal is blood oxygenation level dependent (BOLD) (119) and observable with rapid pulse sequences sensitized to the T2*-weighted contrast (120–122).”
From Electrophysiological source imaging: A noninvasive window to brain dynamics (2018) · cites this paper as [119]
In the citing paper
“This phenomenon is the basis for fMRI (8, 9) and is usually referred to as the blood oxygen level-dependent (BOLD) signal, following Ogawa and colleagues (6).”
From A default mode of brain function (2001) · cites this paper as [6]
In the citing paper
“Because fMRI signal intensity is sensitive to the amount of oxygen carried by hemoglobin (5-7), this change in blood oxygen content at the site of increased brain activity can be detected with fMRI.”
From A default mode of brain function (2001) · cites this paper as [6]
Citations
Cites
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,269
Self-citationPerfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,141
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
NMR chemical shift imaging in three dimensions.
Brown, T. R., Kincaid, B. M., & Uǧurbil, K. (1982) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.79.11.3523 · Cited by 1,045
Frostig, R. D., Lieke, E. E., Ts’o, D. Y., & Grinvald, A. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.16.6082 · Cited by 959
Ogawa, S., & Lee, T. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160103 · Cited by 565
Self-citationSpatially localized 1H NMR spectra of metabolites in the human brain.
Hanstock, C. C., Rothman, D. L., Prichard, J. W., Jue, T., & Shulman, R. G. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.6.1821 · Cited by 189
Optimizing blood vessel contrast in fast three‐dimensional MRI
Haacke, E. M., Masaryk, T. J., Wielopolski, P. A., Zypman, F. R., Tkach, J. A., Amartur, S. C., Mitchell, J., Clampitt, M. E., & Paschal, C. B. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140207 · Cited by 93
Magnetic resonance imaging of perfusion
Bihan, D. L. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140213 · Cited by 77
Time‐of‐flight effects in MR imaging of flow
Wehrli, F. W. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140205 · Cited by 65
Cited by
Sorted by citations
A default mode of brain function
Raichle, M. E., MacLeod, A. M., Snyder, A. Z., Powers, W. J., Gusnard, D. A., & Shulman, G. L. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.2.676 · Cited by 12,190
The brain's default mode network
Raichle, M. E. (2015) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-071013-014030 · Cited by 3,904
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Self-citationThe biopsychosocial approach to chronic pain: Scientific advances and future directions.
Gatchel, R. J., Peng, Y. B., Peters, M. L., Fuchs, P. N., & Turk, D. C. (2007) · Psychological Bulletin · doi:10.1037/0033-2909.133.4.581 · Cited by 3,392
Representational similarity analysis-connecting the branches of systems neuroscience
Kriegeskorte, N. (2008) · Frontiers in Systems Neuroscience · doi:10.3389/neuro.06.004.2008 · Cited by 3,355
Metadata
- Authors
- Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W.
- Affiliations
- AT&T (United States) (US)
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 1990-12
- Volume
- 87
- Issue
- 24
- Pages
- 9868-9872
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC55275
- OpenAlex
- W2071714163
- Cited by
- 6,483
- References
- 12
- Citations by year
- 2026: 148 · 2025: 212 · 2024: 190 · 2023: 189 · 2022: 228 · 2021: 272 · 2020: 242 · 2019: 279 · 2018: 249 · 2017: 272 · 2016: 262 · 2015: 281 · 2014: 283 · 2013: 302 · 2012: 289
- FWCI
- 8.65
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- blood oxygenation level-dependent contrast, BOLD MRI, deoxyhemoglobin, cerebral microvasculature, gradient echo MRI, high-field MRI, anesthetic agents, insulin-induced hypoglycemia, functional MRI
- MeSH terms
- Animals, Blood Flow Velocity, Brain, Carbon Dioxide, Cerebrovascular Circulation, Female, Hemoglobins, Hypoglycemia, Kinetics, Magnetic Resonance Imaging, Models, Neurological, Oxygen, Rats, Inbred Strains, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review