The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Model observers for assessment of image quality.
Open accessAbstract
Image quality can be defined objectively in terms of the performance of some "observer" (either a human or a mathematical model) for some task of practical interest. If the end user of the image will be a human, model observers are used to predict the task performance of the human, as measured by psychophysical studies, and hence to serve as the basis for optimization of image quality. In this paper, we consider the task of detection of a weak signal in a noisy image. The mathematical observers considered include the ideal Bayesian, the nonprewhitening matched filter, a model based on linear-discriminant analysis and referred to as the Hotelling observer, and the Hotelling and Bayesian observers modified to account for the spatial-frequency-selective channels in the human visual system. The theory behind these observer models is briefly reviewed, and several psychophysical studies relating to the choice among them are summarized. Only the Hotelling model with channels is mathematically tractable in all cases considered here and capable of accounting for all of these data. This model requires no adjustment of parameters to fit the data and is relatively insensitive to the details of the channel mechanism. We therefore suggest it as a useful model observer for the purpose of assessing and optimizing image quality with respect to simple detection tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring the Accuracy of Diagnostic Systems
Swets, J. A. (1988) · Science · doi:10.1126/science.3287615 · Cited by 10,058
ROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642
(1982) · Cited by 1,288
Spatial-Frequency Channels in Human Vision*
Sachs, M. B., Nachmias, J., & Robson, J. G. (1971) · Journal of the Optical Society of America · doi:10.1364/josa.61.001176 · Cited by 505
Efficiency of Human Visual Signal Discrimination
Burgess, A. E., Wagner, R. F., Jennings, R. J., & Barlow, H. B. (1981) · Science · doi:10.1126/science.7280685 · Cited by 411
Addition of a channel mechanism to the ideal-observer model
Myers, K. J., & Barrett, H. H. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.002447 · Cited by 400
Self-citationObjective assessment of image quality: effects of quantum noise and object variability
Barrett, H. H. (1990) · Journal of the Optical Society of America A · doi:10.1364/josaa.7.001266 · Cited by 380
Self-citationCHAN, H.-P., DOI, K., VYBRONY, C. J., SCHMIDT, R. A., METZ, C. E., LAM, K. L., OGURA, T., WU, Y., & MACMAHON, H. (1990) · Investigative Radiology · doi:10.1097/00004424-199010000-00006 · Cited by 359
Effect of random background inhomogeneity on observer detection performance
Rolland, J. P., & Barrett, H. H. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.000649 · Cited by 272
Self-citationEffect of noise correlation on detectability of disk signals in medical imaging
Myers, K. J., Barrett, H. H., Borgstrom, M. C., Patton, D. D., & Seeley, G. W. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.001752 · Cited by 205
Self-citationA method of determining the overall quantum efficiency of visual discriminations
Barlow, H. B. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006838 · Cited by 82
Human visual perception and ROC methodology in medical imaging
Chesters, M. S. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/001 · Cited by 63
Giger, M. L., & Doi, K. (1985) · Medical Physics · doi:10.1118/1.595708 · Cited by 48
Doi, K., Giger, M. L., MacMahon, H., Hoffmann, K. R., Nishikawa, R. M., Schmidt, R. A., Chua, K. G., Katsuragawa, S., Nakamori, N., & Sanada, S. (1992) · PubMed · Cited by 44
Cited by
Human observer detection experiments with mammograms and power‐law noise
Burgess, A. E., Jacobson, F. L., & Judy, P. F. (2001) · Medical Physics · doi:10.1118/1.1355308 · Cited by 453
Seven Challenges in Image Quality Assessment: Past, Present, and Future Research
Chandler, D. M. (2013) · ISRN Signal Processing · doi:10.1155/2013/905685 · Cited by 427
Abbey, C. K., & Barrett, H. H. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.000473 · Cited by 324
Self-citationImage quality in CT: From physical measurements to model observers
Verdun, F. R., Racine, D., Ott, J. G., Tapiovaara, M. J., Toroi, P., Bochud, F. O., Veldkamp, W. J. H., Schegerer, A., Bouwman, R. W., Giron, I. H., et al. (2015) · Physica Medica · doi:10.1016/j.ejmp.2015.08.007 · Cited by 300
Iterative reconstruction for helical CT: a simulation study
Nuyts, J., Man, B. D., Dupont, P., Defrise, M., Suetens, P., & Mortelmans, L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/003 · Cited by 291
Metadata
- Authors
- Barrett, H. H., Yao, J., Rolland, J. P., & Myers, K. J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1993-11
- Volume
- 90
- Issue
- 21
- Pages
- 9758-9765
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2067829201
- Cited by
- 531
- References
- 14
- FWCI
- 4.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.