Iterative reconstruction for helical CT: a simulation study

Nuyts, John, Man, Bruno De, Dupont, Patrick, Defrise, Michel, Suetens, Paul, Mortelmans, Luc·1998·Physics in Medicine and Biology

Abstract

Iterative reconstruction algorithms for helical CT are presented. The algorithms are derived from two-dimensional reconstruction algorithms, by adapting the projector/backprojector to the helical orbit of the source, and by constraining the axial frequencies with a Gaussian sieve. Simulations have been carried out and the performance of the iterative algorithms is compared to that of filtered backprojection of synthetic (interpolated) two-dimensional sinograms. The iterative algorithms produce superior bias-noise curves. Axial resolution is superior, but disturbing edge-artefacts are introduced.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/43/4/003

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 291

Metadata

Authors
Nuyts, J., Man, B. D., Dupont, P., Defrise, M., Suetens, P., & Mortelmans, L.
Venue
Physics in Medicine and Biology
Published
1998-04-01
Volume
43
Issue
4
Pages
729-737
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W1964329032
Cited by
291
References
12
FWCI
5.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Iterative reconstruction for helical CT: a simulation study. https://app.cochat.ai/papers/10.1088/0031-9155/43/4/003
The paper
Nuyts, J., Man, B. D., Dupont, P., Defrise, M., Suetens, P., & Mortelmans, L. (1998). Iterative reconstruction for helical CT: a simulation study. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/43/4/003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.