The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
The force generated by a single kinesin molecule against an elastic load.
Open accessAbstract
To probe the mechanism by which the motor protein kinesin moves along microtubules, we have developed a highly sensitive technique for measuring the force exerted by a single motor molecule. In this technique, one end of a microtubule is attached to the tip of a flexible glass fiber of calibrated stiffness. The other end of the microtubule makes contact with a surface sparsely coated with kinesin. By imaging the tip of the glass fiber on a photodiode detector, displacement of the microtubule by kinesin through as little as 1 nm can be detected and forces as small as 1 pN resolved. Using this force-fiber apparatus we have characterized the mechanical output of this molecular motor. The speed at which a molecule of kinesin moved along the surface of a microtubule decreased linearly as the elastic force was increased. The force required to stop a single kinesin molecule was 5.4 +/- 1.0 pN (mean +/- SD; n = 16), independent of the stiffness of the fiber, the damping from the fluid, and whether the ATP concentration was high or low.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910
Bead movement by single kinesin molecules studied with optical tweezers
Block, S. M., Goldstein, L. S. B., & Schnapp, B. J. (1990) · Nature · doi:10.1038/348348a0 · Cited by 1,038
Force and velocity measured for single kinesin molecules
Svoboda, K., & Block, S. M. (1994) · Cell · doi:10.1016/0092-8674(94)90060-4 · Cited by 909
Hirokawa, N., Pfister, K. K., Yorifuji, H., Wagner, M. C., Brady, S. T., & Bloom, G. S. (1989) · Cell · doi:10.1016/0092-8674(89)90691-0 · Cited by 477
Huang, T. G., & Hackney, D. D. (1994) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)34033-4 · Cited by 174
Stewart, R. J., Thaler, J. P., & Goldstein, L. S. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.11.5209 · Cited by 145
Kuznetsov, S. A., Vaisberg, Y. A., Rothwell, S. W., Murphy, D. B., & Gelfand, V. I. (1989) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)31301-7 · Cited by 95
Cited by
Brownian motors: noisy transport far from equilibrium
Reimann, P. (2002) · Physics Reports · doi:10.1016/s0370-1573(01)00081-3 · Cited by 2,589
Single kinesin molecules studied with a molecular force clamp
Visscher, K., Schnitzer, M. J., & Block, S. M. (1999) · Nature · doi:10.1038/22146 · Cited by 1,027
Self-organization of microtubules and motors
Ndlec, F. J., Surrey, T., Maggs, A. C., & Leibler, S. (1997) · Nature · doi:10.1038/38532 · Cited by 884
Myosin-V is a processive actin-based motor
Mehta, A. D., Rock, R. S., Rief, M., Spudich, J. A., Mooseker, M. S., & Cheney, R. E. (1999) · Nature · doi:10.1038/23072 · Cited by 786
Single-Molecule Biomechanics with Optical Methods
Mehta, A. D., Rief, M., Spudich, J. A., Smith, D. A., & Simmons, R. M. (1999) · Science · doi:10.1126/science.283.5408.1689 · Cited by 666
Metadata
- Authors
- Meyhöfer, E., & Howard, J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1995-01-17
- Volume
- 92
- Issue
- 2
- Pages
- 574-578
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2076532008
- Cited by
- 222
- References
- 7
- FWCI
- 3.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The force generated by a single kinesin molecule against an elastic load. https://app.cochat.ai/papers/10.1073/pnas.92.2.574
- The paper
- Meyhöfer, E., & Howard, J. (1995). The force generated by a single kinesin molecule against an elastic load. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.92.2.574
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.