Processing and cryopreservation of placental/umbilical cord blood for unrelated bone marrow reconstitution.
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Clinical evidence of hematopoietic restoration with placental/umbilical cord blood (PCB) grafts indicates that PCB can be a useful source of hematopoietic stem cells for routine bone marrow reconstitution. In the unrelated setting, human leukocyte antigen (HLA)-matched donors must be obtained for candidate patients and, hence, large panels of frozen HLA-typed PCB units must be established. The large volume of unprocessed units, consisting mostly of red blood cells, plasma, and cryopreservation medium, poses a serious difficulty in this effort because storage space in liquid nitrogen is limited and costly. We report here that almost all the hematopoietic colony-forming cells present in PCB units can be recovered in a uniform volume of 20 ml by using rouleaux formation induced by hydroxyethyl starch and centrifugation to reduce the bulk of erythrocytes and plasma and, thus, concentrate leukocytes. This method multiples the number of units that can be stored in the same freezer space as much as 10-fold depending on the format of the storage system. We have also investigated the proportion of functional stem/progenitor cells initially present that are actually available to the recipient when thawed cryopreserved PCB units are infused. Progenitor cell viability is measurably decreased when thawed cells, still suspended in hypertonic cryopreservative solutions, are rapidly mixed with large volumes of isotonic solutions or plasma. The osmotic damage inflicted by the severe solute concentration gradient, however, can be averted by a simple 2-fold dilution after thawing, providing almost total recovery of viable hematopoietic progenitor cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gluckman, E., Broxmeyer, H. E., Auerbach, A. D., Friedman, H. S., Douglas, G. W., Devergie, A., Esperou, H., Thierry, D., Socie, G., Lehn, P., et al. (1989) · New England Journal of Medicine · doi:10.1056/nejm198910263211707 · Cited by 2,094
Broxmeyer, H. E., Douglas, G. W., Hangoc, G., Cooper, S., Bard, J., English, D., Arny, M., Thomas, L., & Boyse, E. A. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.10.3828 · Cited by 1,201
Broxmeyer, H. E., Hangoc, G., Cooper, S., Ribeiro, R. C., Graves, V, Yoder, M., Wagner, J., Vadhan-Raj, S., Benninger, L., & Rubinstein, P. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.9.4109 · Cited by 490
Self-citationStored placental blood for unrelated bone marrow reconstitution
Rubinstein, P., Rosenfield, R., Adamson, J., & Stevens, C. (1993) · Blood · doi:10.1182/blood.v81.7.1679.1679 · Cited by 405
Self-citationOsmotic stress as a mechanism of freezing injury
Meryman, H. T. (1971) · Cryobiology · doi:10.1016/0011-2240(71)90040-x · Cited by 236
Wagner, J., Broxmeyer, H., Byrd, R., Zehnbauer, B., Schmeckpeper, B., Shah, N., Griffin, C., Emanuel, P., Zuckerman, K., & Cooper, S. (1992) · Blood · doi:10.1182/blood.v79.7.1874.1874 · Cited by 219
Adverse reactions in patients transfused with cryopreserved marrow
Stroncek, D., Fautsch, S., Lasky, L., Hurd, D., Ramsay, N., & McCullough, J. (1991) · Transfusion · doi:10.1046/j.1537-2995.1991.31691306250.x · Cited by 184
Collection, separation and cryopreservation of umbilical cord blood for use in transplantation.
Dt, H., Mj, S., Rychlik, S., Booth, A., Acevedo, A., Rubinstein, P. G., Bard, J., & Boyse, E. A. (1994) · PubMed · Cited by 151
Self-citation
Cited by
Mesenchymal progenitor cells in human umbilical cord blood
Erices, A., Conget, P., & Minguell, J. J. (2000) · British Journal of Haematology · doi:10.1046/j.1365-2141.2000.01986.x · Cited by 1,613
Outcomes among 562 Recipients of Placental-Blood Transplants from Unrelated Donors
Rubinstein, P., Carrier, C., Scaradavou, A., Kurtzberg, J., Adamson, J., Migliaccio, A. R., Berkowitz, R. L., Cabbad, M., Dobrila, N. L., Taylor, P. E., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199811263392201 · Cited by 1,319
Self-citationOutcome of Cord-Blood Transplantation from Related and Unrelated Donors
Gluckman, E., Rocha, V., Boyer-Chammard, A., Locatelli, F., Arcese, W., Pasquini, R., Ortega, J., Souillet, G., Ferreira, E., Laporte, J.-P., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199708073370602 · Cited by 1,249
Brunstein, C. G., Miller, J. S., Cao, Q., McKenna, D. H., Hippen, K. L., Curtsinger, J., DeFor, T., Levine, B. L., June, C. H., Rubinstein, P., et al. (2011) · Blood · doi:10.1182/blood-2010-07-293795 · Cited by 1,045
Self-citationKurtzberg, J., Laughlin, M., Graham, M. L., Smith, C., Olson, J. F., Halperin, E. C., Ciocci, G., Carrier, C., Stevens, C. E., & Rubinstein, P. (1996) · New England Journal of Medicine · doi:10.1056/nejm199607183350303 · Cited by 1,024
Self-citationWagner, J. E., Barker, J. N., DeFor, T. E., Baker, K. S., Blazar, B. R., Eide, C., Goldman, A., Kersey, J., Krivit, W., MacMillan, M. L., et al. (2002) · Blood · doi:10.1182/blood-2002-01-0294 · Cited by 1,010
Laughlin, M. J., Barker, J., Bambach, B., Koc, O. N., Rizzieri, D. A., Wagner, J. E., Gerson, S. L., Lazarus, H. M., Cairo, M., Stevens, C. E., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106143442402 · Cited by 882
Self-citationBarker, J. N., Weisdorf, D. J., DeFor, T. E., Blazar, B. R., McGlave, P. B., Miller, J. S., Verfaillie, C. M., & Wagner, J. E. (2005) · Blood · doi:10.1182/blood-2004-07-2717 · Cited by 865
Delaney, C., Heimfeld, S., Brashem-Stein, C., Voorhies, H., Manger, R. L., & Bernstein, I. D. (2010) · Nature Medicine · doi:10.1038/nm.2080 · Cited by 771
Transplantation of Umbilical-Cord Blood in Babies with Infantile Krabbe's Disease
Escolar, M. L., Poe, M. D., Provenzale, J. M., Richards, K. C., Allison, J., Wood, S., Wenger, D. A., Pietryga, D., Wall, D., Champagne, M., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa042604 · Cited by 709
Brunstein, C. G., Barker, J. N., Weisdorf, D. J., DeFor, T. E., Miller, J. S., Blazar, B. R., McGlave, P. B., & Wagner, J. E. (2007) · Blood · doi:10.1182/blood-2007-04-067215 · Cited by 501
Cord-Blood Transplants from Unrelated Donors in Patients with Hurler's Syndrome
Staba, S. L., Escolar, M. L., Poe, M., Kim, Y., Martin, P. L., Szabolcs, P., Allison-Thacker, J., Wood, S., Wenger, D. A., Rubinstein, P., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032613 · Cited by 478
Self-citationFactors associated with outcomes of unrelated cord blood transplant: Guidelines for donor choice
Gluckman, E., Rocha, V., Arcese, W., Michel, G., Sanz, G., Chan, K.-W., Takahashi, T. A., Ortega, J., Filipovich, A., Locatelli, F., et al. (2004) · Experimental Hematology · doi:10.1016/j.exphem.2004.01.002 · Cited by 394
Related umbilical cord blood transplantation in patients with thalassemia and sickle cell disease
Locatelli, F. (2003) · Blood · doi:10.1182/blood-2002-07-2090 · Cited by 386
Transplantation of ex vivo expanded cord blood
Shpall, E. J., Quinones, R., Giller, R., Zeng, C., Baron, A. E., Jones, R. B., Bearman, S. I., Nieto, Y., Freed, B., Madinger, N., et al. (2002) · Biology of Blood and Marrow Transplantation · doi:10.1053/bbmt.2002.v8.pm12171483 · Cited by 372
Wagner, J. E., Brunstein, C. G., Boitano, A. E., DeFor, T. E., McKenna, D., Sumstad, D., Blazar, B. R., Tolar, J., Le, C., Jones, J., et al. (2016) · Cell Stem Cell · doi:10.1016/j.stem.2015.10.004 · Cited by 335
Cryopreservation of Human Stem Cells for Clinical Application: A Review
Hunt, C. J. (2011) · Transfusion Medicine and Hemotherapy · doi:10.1159/000326623 · Cited by 329
Mesenchymal stem cells engineered for cancer therapy
Shah, K. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.06.010 · Cited by 322
SOGC Clinical Practice Guidelines
Lalonde, A. B. (1995) · Journal SOGC · doi:10.1016/s1701-2163(16)30568-0 · Cited by 306
Jaroscak, J., Goltry, K., Smith, A., Waters-Pick, B., Martin, P. L., Driscoll, T. A., Howrey, R., Chao, N., Douville, J., Burhop, S., et al. (2003) · Blood · doi:10.1182/blood-2001-12-0290 · Cited by 302
Verneris, M. R., Brunstein, C. G., Barker, J., MacMillan, M. L., DeFor, T., McKenna, D. H., Burke, M. J., Blazar, B. R., Miller, J. S., McGlave, P. B., et al. (2009) · Blood · doi:10.1182/blood-2009-05-220525 · Cited by 299
Kurtzberg, J., Prasad, V. K., Carter, S. L., Wagner, J. E., Baxter-Lowe, L. A., Wall, D., Kapoor, N., Guinan, E. C., Feig, S. A., Wagner, E. L., et al. (2008) · Blood · doi:10.1182/blood-2007-06-098020 · Cited by 295
Migliaccio, A. R., Adamson, J. W., Stevens, C. E., Dobrila, N. L., Carrier, C. M., & Rubinstein, P. (2000) · Blood · doi:10.1182/blood.v96.8.2717 · Cited by 293
Self-citationPrasad, V. K., Mendizabal, A., Parikh, S. H., Szabolcs, P., Driscoll, T. A., Page, K., Lakshminarayanan, S., Allison, J., Wood, S., Semmel, D., et al. (2008) · Blood · doi:10.1182/blood-2008-03-140830 · Cited by 262
Awan, M., Buriak, I., Fleck, R., Fuller, B., Goltsev, A., Kerby, J., Lowdell, M., Mericka, P., Petrenko, A., Petrenko, Y., et al. (2020) · Regenerative Medicine · doi:10.2217/rme-2019-0145 · Cited by 253
Zhang, X., Hirai, M., Cantero, S., Ciubotariu, R., Dobrila, L., Hirsh, A., Igura, K., Satoh, H., Yokomi, I., Nishimura, T., et al. (2011) · Journal of Cellular Biochemistry · doi:10.1002/jcb.23042 · Cited by 248
“Moreover, CB banking systems have been developed worldwide meeting technical requirements for clinical grade cellular products [Rubinstein et al., 1995; Rubinstein, 2009; Garcia, 2010].”
BackgroundMethodSelf-citationBiology of Human Umbilical Cord Blood‐Derived Hematopoietic Stem/Progenitor Cells
Mayani, H., & Lansdorp, P. M. (1998) · STEM CELLS · doi:10.1002/stem.160153 · Cited by 246
Locatelli, F., Kabbara, N., Ruggeri, A., Ghavamzadeh, A., Roberts, I., Li, C. K., Bernaudin, F., Vermylen, C., Dalle, J.-H., Stein, J., et al. (2013) · Blood · doi:10.1182/blood-2013-03-489112 · Cited by 244
“Median body weight, kg (range) 23 (7-71) 19 (10-60) .”
Hofmeister, C. C., Zhang, J., Knight, K. L., Le, P., & Stiff, P. J. (2007) · Bone Marrow Transplantation · doi:10.1038/sj.bmt.1705538 · Cited by 219
Onofre, J., Baert, Y., Faes, K., & Goossens, E. (2016) · Human Reproduction Update · doi:10.1093/humupd/dmw029 · Cited by 211
“…reported DMSO to be suitable for safe and effective handling of human testicular cells and tissues, as it has been validated in human cord blood (Rubinstein et al., 1995), bone marrow (Odavic et al., 1980) and peripheral blood stem cell freezing (Körbling and Freireich, 2011) and other clinical…”
BackgroundPeled, T., Shoham, H., Aschengrau, D., Yackoubov, D., Frei, G., Rosenheimer G, N., Lerrer, B., Cohen, H. Y., Nagler, A., Fibach, E., et al. (2012) · Experimental Hematology · doi:10.1016/j.exphem.2011.12.005 · Cited by 197
“[30].”
Cord Blood Banking for Potential Future Transplantation
Allergy/Immunology, S. O. H. A. S. O. (2007) · Pediatrics · doi:10.1542/peds.2006-2901 · Cited by 181
Kögler, G., Radke, T. F., Lefort, A., Sensken, S., Fischer, J., Sorg, R. V., & Wernet, P. (2005) · Experimental Hematology · doi:10.1016/j.exphem.2005.01.012 · Cited by 166
“Generation and expansion of USSC from cryoconserved CB Thawing of volume-reduced (n 66) CB units was performed as described previously [21,22].”
BackgroundMethodNew trends in umbilical cord blood transplantation
Ballen, K. K. (2005) · Blood · doi:10.1182/blood-2004-10-4125 · Cited by 165
Page, K. M., Zhang, L., Mendizabal, A., Wease, S., Carter, S., Gentry, T., Balber, A. E., & Kurtzberg, J. (2011) · Biology of Blood and Marrow Transplantation · doi:10.1016/j.bbmt.2011.01.011 · Cited by 165
De Felice, L., Tatarelli, C., Mascolo, M. G., Gregorj, C., Agostini, F., Fiorini, R., Gelmetti, V., Pascale, S., Padula, F., Petrucci, M. T., et al. (2005) · Cancer Research · doi:10.1158/0008-5472.can-04-3063 · Cited by 149
“Research Article according to Rubinstein et al. ( 35 ).”
MethodOutcomes of Unrelated Umbilical Cord Blood Transplantation for X-Linked Adrenoleukodystrophy
Beam, D., Poe, M. D., Provenzale, J. M., Szabolcs, P., Martin, P. L., Prasad, V., Parikh, S., Driscoll, T., Mukundan, S., Kurtzberg, J., et al. (2007) · Biology of Blood and Marrow Transplantation · doi:10.1016/j.bbmt.2007.01.082 · Cited by 83
Metadata
- Authors
- Rubinstein, P., Dobrila, L., Rosenfield, R. E., Adamson, J. W., Migliaccio, G., Migliaccio, A. R., Taylor, P. E., & Stevens, C. E.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1995-10-24
- Volume
- 92
- Issue
- 22
- Pages
- 10119-10122
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2010055592
- Cited by
- 819
- References
- 8
- FWCI
- 10.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.