CoChat

Movements of truncated kinesin fragments with a short or an artificial flexible neck

Open access
Inoue, Yuichi, Toyoshima, Yoko Yano, Iwane, Atsuko Hikikoshi, Morimoto, Sayuri, Higuchi, Hideo, Yanagida, Toshio · 1997 · Proceedings of the National Academy of Sciences
Cited by 63

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

To investigate the role of the neck domain of kinesin, we used optical trapping nanometry to perform high-resolution measurements of the movements and forces produced by recombinant kinesin fragments in which the neck domains were shortened or replaced by an artificial random coil. Truncated kinesin fragments (K351) that contain a motor domain consisting of ≈340 aa and a short neck domain consisting of ≈11 aa showed fast movement (800 nm/s) and 8-nm steps. Such behavior was similar to that of recombinant fragments containing the full-length neck domain (K411) and to that of native kinesin. Kinesin fragments lacking the short neck domain (K340), however, showed very slow movement (<50 nm/s), as previously reported. Joining an artificial 11-aa sequence that was expected to form a flexible random chain to the motor domain (K340–chain) produced normal fast (≈700 nm/s) and stepwise movement. The results suggest that the neck domain does not act as a rigid lever arm to magnify the structural change at the catalytic domain as has been believed for myosin, but it does act as a flexible joint to guarantee the mobility of the motor domain.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.94.14.7275

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 63

Metadata

Authors
Inoue, Y., Toyoshima, Y. Y., Iwane, A. H., Morimoto, S., Higuchi, H., & Yanagida, T.
Venue
Proceedings of the National Academy of Sciences
Published
1997-07-08
Volume
94
Issue
14
Pages
7275-7280
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2095051959
Cited by
63
References
5
FWCI
2.54
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Movements of truncated kinesin fragments with a short or an artificial flexible neck. https://app.cochat.ai/papers/10.1073/pnas.94.14.7275
The paper
Inoue, Y., Toyoshima, Y. Y., Iwane, A. H., Morimoto, S., Higuchi, H., & Yanagida, T. (1997). Movements of truncated kinesin fragments with a short or an artificial flexible neck. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.94.14.7275

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.