Real time detection of DNA⋅RNA hybridization in living cells
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Demonstrating hybridization between an antisense oligodeoxynucleotide and its mRNA target has proven to be extremely difficult in living cells. To address this fundamental problem in antisense research, we synthesized “molecular beacon” (MB) reporter oligodeoxynucleotides with matched fluorescent donor and acceptor chromophores on their 5′ and 3′ ends. In the absence of a complementary nucleic acid strand, the MB remains in a stem–loop conformation where fluorescence resonance energy transfer prevents signal emission. On hybridization with a complementary sequence, the stem–loop structure opens increasing the physical distance between the donor and acceptor moieties thereby reducing fluorescence resonance energy transfer and allowing a detectable signal to be emitted when the beacon is excited by light of the appropriate wavelength. Solution hybridization studies revealed that in the presence of a complementary strand targeted MB could yield up to a 60-fold increase in fluorescence intensity in comparison to control MB. By using a fluorescence microscope fitted with UV fluoride lenses, the detection limit of preformed MB/target sequence duplexes microinjected into cells was found to be ≥1 × 10 −1 ag of MB, or ∼10 molecules of mRNA. On the basis of this exquisite sensitivity, real-time detection of MB/target mRNA hybridization in living cells was attempted by microinjecting MB targeted to the vav protooncogene, or control MB, into K562 human leukemia cells. Within 15 min, confocal microscopy revealed fluorescence in cells injected with targeted, but not control, MB. These studies suggest that real-time visualization and localization of oligonucleotide/mRNA interactions is now possible. MB could find utility in studying RNA processing, trafficking, and folding in living cells. We hypothesize that MB may also prove useful for finding targetable mRNA sequence under physiologic conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Single-step method of RNA isolation by acid guanidinium thiocyanate-phenol-chloroform extraction
Chomczynski, P., & Sacchi, N. (1987) · Analytical Biochemistry · doi:10.1016/0003-2697(87)90021-2 · Cited by 46,426
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Multicolor molecular beacons for allele discrimination
Tyagi, S., Bratu, D. P., & Kramer, F. R. (1998) · Nature Biotechnology · doi:10.1038/nbt0198-49 · Cited by 1,320
Resonance Energy Transfer: Methods and Applications
Wu, P. G., & Brand, L. (1994) · Analytical Biochemistry · doi:10.1006/abio.1994.1134 · Cited by 1,277
Monia, B. P., Lesnik, E. A., Gonzalez, C., Lima, W. F., McGee, D., Guinosso, C. J., Kawasaki, A. M., Cook, P. D., & Freier, S. M. (1993) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)85268-7 · Cited by 778
Nuclease Resistance and Antisense Activity of Modified Oligonucleotides Targeted to Ha-
Monia, B. P., Johnston, J. F., Sasmor, H., & Cummins, L. L. (1996) · Journal of Biological Chemistry · doi:10.1074/jbc.271.24.14533 · Cited by 176
Fluorescence energy transfer as a probe for nucleic acid structures and sequences
Mergny, J., Boutorine, A. S., Garestier, T., Belloc, F., Rougée, M., Bulychev, N. V., Koshkin, A. A., Bourson, J., Lebedev, A. V., Valeur, B., et al. (1994) · Nucleic Acids Research · doi:10.1093/nar/22.6.920 · Cited by 132
Comparative evaluation of seven oligonucleotide analogs as potential antisense agents
Morvan, F., Porumb, H., Degols, G., Lefèbvre, I., Pompon, A., Sproat, B. S., Rayner, B., Malvy, C., Lebleu, B., & Imbach, J. (1993) · Journal of Medicinal Chemistry · doi:10.1021/jm00054a013 · Cited by 123
Boden, S. D., Hair, G. A., Titus, L., Racine, M., McCuaig, K. A., Wozney, J. M., & Nanes, M. S. (1997) · Endocrinology · doi:10.1210/en.138.7.2820 · Cited by 120
Facilitating oligonucleotide delivery: helping antisense deliver on its promise.
Gewirtz, A. M., Stein, C. A., & Glazer, P. M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.8.3161 · Cited by 108
Self-citation
Cited by
Bustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
Gold Nanoparticles for Biology and Medicine
Giljohann, D. A., Seferos, D. S., Daniel, W. L., Massich, M. D., Patel, P. C., & Mirkin, C. A. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200904359 · Cited by 2,356
MicroRNA: Function, Detection, and Bioanalysis
Dong, H., Lei, J., Ding, L., Wen, Y., Ju, H., & Zhang, X. (2013) · Chemical Reviews · doi:10.1021/cr300362f · Cited by 1,224
Self-citationCell and molecular mechanics of biological materials
Bao, G., & Suresh, S. (2003) · Nature Materials · doi:10.1038/nmat1001 · Cited by 1,055
Dong, H., Gao, W., Yan, F., Ji, H., & Ju, H. (2010) · Analytical Chemistry · doi:10.1021/ac100852z · Cited by 777
Nano-Flares: Probes for Transfection and mRNA Detection in Living Cells
Seferos, D. S., Giljohann, D. A., Hill, H. D., Prigodich, A. E., & Mirkin, C. A. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0776529 · Cited by 710
A DNA−Silver Nanocluster Probe That Fluoresces upon Hybridization
Yeh, H.-C., Sharma, J., Han, J. J., Martinez, J. S., & Werner, J. H. (2010) · Nano Letters · doi:10.1021/nl101773c · Cited by 654
Molecular Engineering of DNA: Molecular Beacons
Wang, K., Tang, Z., Yang, C. J., Kim, Y., Fang, X., Li, W., Wu, Y., Medley, C. D., Cao, Z., Li, J., et al. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200800370 · Cited by 644
Nucleic-acid therapeutics: basic principles and recent applications
Opalinska, J. B., & Gewirtz, A. M. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd837 · Cited by 537
Self-citationProgrammable RNA Tracking in Live Cells with CRISPR/Cas9
Nelles, D. A., Fang, M. Y., O’Connell, M. R., Xu, J. L., Markmiller, S. J., Doudna, J. A., & Yeo, G. W. (2016) · Cell · doi:10.1016/j.cell.2016.02.054 · Cited by 527
Tan, W., Wang, K., & Drake, T. J. (2004) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2004.08.010 · Cited by 461
Visualizing the distribution and transport of mRNAs in living cells
Bratu, D. P., Cha, B.-J., Mhlanga, M. M., Kramer, F. R., & Tyagi, S. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2233244100 · Cited by 440
Progress in antisense technology
Crooke, S. T. (2004) · Annual Review of Medicine · doi:10.1146/annurev.med.55.091902.104408 · Cited by 417
DNA Probes Using Fluorescence Resonance Energy Transfer (FRET): Designs and Applications
Didenko, V. V. (2001) · BioTechniques · doi:10.2144/01315rv02 · Cited by 408
Imaging biochemistry inside cells
Wouters, F. S., Verveer, P. J., & Bastiaens, P. I. H. (2001) · Trends in Cell Biology · doi:10.1016/s0962-8924(01)01982-1 · Cited by 395
Dual FRET molecular beacons for mRNA detection in living cells
Santangelo, P. J. (2004) · Nucleic Acids Research · doi:10.1093/nar/gnh062 · Cited by 373
Nanochannel electroporation delivers precise amounts of biomolecules into living cells
Boukany, P. E., Morss, A., Liao, W.-C., Henslee, B., Jung, H., Zhang, X., Yu, B., Wang, X., Wu, Y., Li, L., et al. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.164 · Cited by 338
Self-citationHybridization kinetics and thermodynamics of molecular beacons
Tsourkas, A. (2003) · Nucleic Acids Research · doi:10.1093/nar/gkg212 · Cited by 316
Molecular Aptamer Beacons for Real-Time Protein Recognition
Li, J. J., Fang, X., & Tan, W. (2002) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2002.6581 · Cited by 294
Noninvasive real-time imaging of apoptosis
Laxman, B., Hall, D. E., Bhojani, M. S., Hamstra, D. A., Chenevert, T. L., Ross, B. D., & Rehemtulla, A. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.252644499 · Cited by 247
Enzymatic signal amplification of molecular beacons for sensitive DNA detection
Li, J. J., Chu, Y., Lee, B. Y.-H., & Xie, X. S. (2008) · Nucleic Acids Research · doi:10.1093/nar/gkn033 · Cited by 226
“If beacon-binding site is represented by S, and m is the average number of beacon-binding sites induced by one T molecule, then the total concentration of S is ½St ¼ m½Tt ð27Þ Apply Equation (19) to extended NESA, V0 ¼ K 0 0 ½St ð28Þ K00 is the pseudo first-order rate constant for the nicking reaction in extended NESA.”
InfluentialDu, B., Li, Z., & Liu, C. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200603331 · Cited by 173
Peng, X.-H., Cao, Z.-H., Xia, J.-T., Carlson, G. W., Lewis, M. M., Wood, W. C., & Yang, L. (2005) · Cancer Research · doi:10.1158/0008-5472.can-04-3196 · Cited by 167
“It has also been shown that the detection limit of preformed molecular beacon/ h-actin mRNA duplexes microinjected into the cells is 10 mRNA molecules, suggesting that molecular beacon technology is a very sensitive method for detecting mRNAs in cells (9).”
Method
Metadata
- Authors
- Sokol, D. L., Zhang, X., Lu, P., & Gewirtz, A. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1998-09-29
- Volume
- 95
- Issue
- 20
- Pages
- 11538-11543
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1987069778
- Cited by
- 373
- References
- 25
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.