The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Force-mediated kinetics of single P-selectin/ligand complexes observed by atomic force microscopy
Open accessAbstract
Leukocytes roll along the endothelium of postcapillary venules in response to inflammatory signals. Rolling under the hydrodynamic drag forces of blood flow is mediated by the interaction between selectins and their ligands across the leukocyte and endothelial cell surfaces. Here we present force-spectroscopy experiments on single complexes of P-selectin and P-selectin glycoprotein ligand-1 by atomic force microscopy to determine the intrinsic molecular properties of this dynamic adhesion process. By modeling intermolecular and intramolecular forces as well as the adhesion probability in atomic force microscopy experiments we gain information on rupture forces, elasticity, and kinetics of the P-selectin/P-selectin glycoprotein ligand-1 interaction. The complexes are able to withstand forces up to 165 pN and show a chain-like elasticity with a molecular spring constant of 5.3 pN nm −1 and a persistence length of 0.35 nm. The dissociation constant (off-rate) varies over three orders of magnitude from 0.02 s −1 under zero force up to 15 s −1 under external applied forces. Rupture force and lifetime of the complexes are not constant, but directly depend on the applied force per unit time, which is a product of the intrinsic molecular elasticity and the external pulling velocity. The high strength of binding combined with force-dependent rate constants and high molecular elasticity are tailored to support physiological leukocyte rolling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Selectins and their ligands: Current concepts and controversies
Kansas, G. (1996) · Blood · doi:10.1182/blood.v88.9.3259.bloodjournal8893259 · Cited by 1,415
Cited by
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
Self-citationDynamic force spectroscopy of single DNA molecules
Strunz, T., Oroszlan, K., Schäfer, R., & Güntherodt, H.-J. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.20.11277 · Cited by 580
Clarke, S. R., Andre, G., Walsh, E. J., Dufrêne, Y. F., Foster, T. J., & Foster, S. J. (2009) · Infection and Immunity · doi:10.1128/iai.01304-08 · Cited by 105
Applications of biosensing atomic force microscopy in monitoring drug and nanoparticle delivery
Lamprecht, C., Hinterdorfer, P., & Ebner, A. (2014) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2014.917078 · Cited by 46
Origin of Friction Derived from Rupture Dynamics
Suda, H. (2001) · Langmuir · doi:10.1021/la0106384 · Cited by 25
Metadata
- Authors
- Fritz, J., Katopodis, A. G., Kolbinger, F., & Anselmetti, D.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1998-10-13
- Volume
- 95
- Issue
- 21
- Pages
- 12283-12288
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2053363846
- Cited by
- 394
- References
- 1
- FWCI
- 13.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Force-mediated kinetics of single P-selectin/ligand complexes observed by atomic force microscopy. https://app.cochat.ai/papers/10.1073/pnas.95.21.12283
- The paper
- Fritz, J., Katopodis, A. G., Kolbinger, F., & Anselmetti, D. (1998). Force-mediated kinetics of single P-selectin/ligand complexes observed by atomic force microscopy. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.95.21.12283
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.