The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Real-time enzyme kinetics monitored by dual-color fluorescence cross-correlation spectroscopy
Open accessAbstract
A method for sensitively monitoring enzyme kinetics and activities by using dual-color fluorescence cross-correlation spectroscopy is described. This universal method enables the development of highly sensitive and precise assays for real-time kinetic analyses of any catalyzed cleavage or addition reaction, where a chemical linkage is formed or cleaved through an enzyme’s action between two fluorophores that can be discriminated spectrally. In this work, a homogeneous assay with restriction endonuclease Eco RI and a 66-bp double-stranded DNA containing the GAATTC recognition site and fluorophores at each 5′ end is described. The enzyme activity can be quantified down to the low picomolar range (>1.6 pM) where the rate constants are linearly dependent on the enzyme concentrations over two orders of magnitude. Furthermore, the reactions were monitored on-line at various initial substrate concentrations in the nanomolar range, and the reaction rates were clearly represented by the Michaelis–Menten equation with a K M of 14 ± 1 nM and a k cat of 4.6 ± 0.2 min −1 . In addition to kinetic studies and activity determinations, it is proposed that enzyme assays based on the dual-color fluorescence cross-correlation spectroscopy will be very useful for high-throughput screening and evolutionary biotechnology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermodynamic Fluctuations in a Reacting System—Measurement by Fluorescence Correlation Spectroscopy
Magde, D., Elson, E., & Webb, W. W. (1972) · Physical Review Letters · doi:10.1103/physrevlett.29.705 · Cited by 1,753
Fluorescence correlation spectroscopy. II. An experimental realization
Magde, D., Elson, E. L., & Webb, W. W. (1974) · Biopolymers · doi:10.1002/bip.1974.360130103 · Cited by 1,512
Fluorescence correlation spectroscopy. I. Conceptual basis and theory
Elson, E. L., & Magde, D. (1974) · Biopolymers · doi:10.1002/bip.1974.360130102 · Cited by 1,436
Rigler, R., Mets, �., Widengren, J., & Kask, P. (1993) · European Biophysics Journal · doi:10.1007/bf00185777 · Cited by 1,002
Sorting single molecules: application to diagnostics and evolutionary biotechnology.
Eigen, M., & Rigler, R. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.13.5740 · Cited by 956
Self-citationSchwille, P., Meyer-Almes, F. J., & Rigler, R. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78833-7 · Cited by 817
Self-citationRotational brownian motion and fluorescence intensify fluctuations
Ehrenberg, M., & Rigler, R. (1974) · Chemical Physics · doi:10.1016/0301-0104(74)85005-6 · Cited by 366
DNA Nucleotide Sequence Restricted by the RI Endonuclease
Hedgpeth, J., Goodman, H. M., & Boyer, H. W. (1972) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.69.11.3448 · Cited by 362
Fluorescence correlation spectroscopy: Diagnostics for sparse molecules
Maiti, S., Haupts, U., & Webb, W. W. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.22.11753 · Cited by 317
Nordlund, T. M., Andersson, S., Nilsson, L., Rigler, R., Graeslund, A., & McLaughlin, L. W. (1989) · Biochemistry · doi:10.1021/bi00449a021 · Cited by 227
Cited by
Fluorescent Proteins and Their Applications in Imaging Living Cells and Tissues
Chudakov, D. M., Matz, M. V., Lukyanov, S., & Lukyanov, K. A. (2010) · Physiological Reviews · doi:10.1152/physrev.00038.2009 · Cited by 1,375
Schwille, P., Haupts, U., Maiti, S., & Webb, W. W. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77065-7 · Cited by 722
Self-citationFluorescence Correlation Spectroscopy
(2011) · SpringerReference · doi:10.1007/springerreference_33960 · Cited by 714
Biological and Chemical Applications of Fluorescence Correlation Spectroscopy: A Review
Hess, S. T., Huang, S., Heikal, A. A., & Webb, W. W. (2002) · Biochemistry · doi:10.1021/bi0118512 · Cited by 653
Fluorescence cross-correlation spectroscopy in living cells
Bacia, K., Kim, S. A., & Schwille, P. (2006) · Nature Methods · doi:10.1038/nmeth822 · Cited by 617
Self-citationMüller, B. K., Zaychikov, E., Bräuchle, C., & Lamb, D. C. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.064766 · Cited by 568
Deniz, A. A., Dahan, M., Grunwell, J. R., Ha, T., Faulhaber, A. E., Chemla, D. S., Weiss, S., & Schultz, P. G. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.7.3670 · Cited by 547
High-throughput screening: new technology for the 21st century
Hertzberg, R. P., & Pope, A. J. (2000) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00110-1 · Cited by 539
Kask, P., Palo, K., Ullmann, D., & Gall, K. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.24.13756 · Cited by 455
Fluorescence Correlation Spectroscopy and Its Potential for Intracellular Applications
Schwille, P. (2001) · Cell Biochemistry and Biophysics · doi:10.1385/cbb:34:3:383 · Cited by 367
Self-citationKogure, T., Karasawa, S., Araki, T., Saito, K., Kinjo, M., & Miyawaki, A. (2006) · Nature Biotechnology · doi:10.1038/nbt1207 · Cited by 317
Single Molecule Fluorescence Spectroscopy at Ambient Temperature
Ambrose, W. P., Goodwin, P. M., Jett, J. H., Van Orden, A., Werner, J. H., & Keller, R. A. (1999) · Chemical Reviews · doi:10.1021/cr980132z · Cited by 317
Practical guidelines for dual-color fluorescence cross-correlation spectroscopy
Bacia, K., & Schwille, P. (2007) · Nature Protocols · doi:10.1038/nprot.2007.410 · Cited by 270
Self-citationTechnological advances in high-throughput screening
Fernandes, P. B. (1998) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(98)80089-6 · Cited by 170
Metadata
- Authors
- Kettling, U., Koltermann, A., Schwille, P., & Eigen, M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1998-02-17
- Volume
- 95
- Issue
- 4
- Pages
- 1416-1420
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2154892443
- Cited by
- 308
- References
- 23
- FWCI
- 13.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.