The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Fluorescence-intensity distribution analysis and its application in biomolecular detection technology
Open accessAbstract
A methodology, fluorescence-intensity distribution analysis, has been developed for confocal microscopy studies in which the fluorescence intensity of a sample with a heterogeneous brightness profile is monitored. An adjustable formula, modeling the spatial brightness distribution, and the technique of generating functions for calculation of theoretical photon count number distributions serve as the two cornerstones of the methodology. The method permits the simultaneous determination of concentrations and specific brightness values of a number of individual fluorescent species in solution. Accordingly, we present an extremely sensitive tool to monitor the interaction of fluorescently labeled molecules or other microparticles with their respective biological counterparts that should find a wide application in life sciences, medicine, and drug discovery. Its potential is demonstrated by studying the hybridization of 5′-(6-carboxytetramethylrhodamine)-labeled and nonlabeled complementary oligonucleotides and the subsequent cleavage of the DNA hybrids by restriction enzymes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Thermodynamic Fluctuations in a Reacting System—Measurement by Fluorescence Correlation Spectroscopy
Magde, D., Elson, E., & Webb, W. W. (1972) · Physical Review Letters · doi:10.1103/physrevlett.29.705 · Cited by 1,753
Fluorescence correlation spectroscopy. II. An experimental realization
Magde, D., Elson, E. L., & Webb, W. W. (1974) · Biopolymers · doi:10.1002/bip.1974.360130103 · Cited by 1,512
Widengren, J., Mets, U., & Rigler, R. (1995) · The Journal of Physical Chemistry · doi:10.1021/j100036a009 · Cited by 759
Iterative methods for image deblurring
Biemond, J., Lagendijk, R. L., & Mersereau, R. M. (1990) · Proceedings of the IEEE · doi:10.1109/5.53403 · Cited by 460
Monitoring conformational dynamics of a single molecule by selective fluorescence spectroscopy
Eggeling, C., Fries, J. R., Brand, L., Günther, R., & Seidel, C. A. M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.4.1556 · Cited by 341
Real-time enzyme kinetics monitored by dual-color fluorescence cross-correlation spectroscopy
Kettling, U., Koltermann, A., Schwille, P., & Eigen, M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.4.1416 · Cited by 308
Conformational fluctuations in single DNA molecules
Wennmalm, S., Edman, L., & Rigler, R. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.20.10641 · Cited by 183
Distribution of molecular aggregation by analysis of fluctuation moments.
Qian, H., & Elson, E. L. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.14.5479 · Cited by 179
On the analysis of high order moments of fluorescence fluctuations
Qian, H., & Elson, E. L. (1990) · Biophysical Journal · doi:10.1016/s0006-3495(90)82539-x · Cited by 166
Cited by
Different Species of α-Synuclein Oligomers Induce Calcium Influx and Seeding
Danzer, K. M., Haasen, D., Karow, A. R., Moussaud, S., Habeck, M., Giese, A., Kretzschmar, H., Hengerer, B., & Kostka, M. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.2617-07.2007 · Cited by 765
Gehlen, M. H. (2020) · Journal of Photochemistry and Photobiology C: Photochemistry Reviews · doi:10.1016/j.jphotochemrev.2019.100338 · Cited by 734
Fluorescence Correlation Spectroscopy: Past, Present, Future
Elson, E. L. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.11.012 · Cited by 438
Fluorescence Lifetime Imaging Microscopy for Quantitative Biological Imaging
Chen, L.-C., Lloyd, W. R., Chang, C.-W., Sud, D., & Mycek, M.-A. (2013) · Methods in Cell Biology · doi:10.1016/b978-0-12-407761-4.00020-8 · Cited by 55
Metadata
- Authors
- Kask, P., Palo, K., Ullmann, D., & Gall, K.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1999-11-23
- Volume
- 96
- Issue
- 24
- Pages
- 13756-13761
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2073271190
- Cited by
- 455
- References
- 11
- FWCI
- 12.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence-intensity distribution analysis and its application in biomolecular detection technology. https://app.cochat.ai/papers/10.1073/pnas.96.24.13756
- The paper
- Kask, P., Palo, K., Ullmann, D., & Gall, K. (1999). Fluorescence-intensity distribution analysis and its application in biomolecular detection technology. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.96.24.13756
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.