Neuronal Ca2+ Sensor 1, the Mammalian Homologue of Frequenin, Is Expressed in Chromaffin and PC12 Cells and Regulates Neurosecretion from Dense-core Granules
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Neuronal Ca2+ sensor 1 (NCS-1) is the mammalian homologue of the Ca2+-binding protein frequenin previously implicated in regulation of neurotransmission in Drosophila (Pongs, O., Lindemeier, J., Zhu, X. R., Theil, T., Endelkamp, D., Krah-Jentgens, I., Lambrecht, H.-G., Koch, K. W., Schwemer, J., Rivosecchi, R., Mallart, A., Galceran, J. , Canal, I., Barbas, J. A., and Ferrus, A. (1993) Neuron 11, 15-28). NCS-1 has been considered to be expressed only in neurons, but we show that NCS-1 expression can be detected in bovine adrenal chromaffin and PC12 cells, two widely studied model neuroendocrine cells. NCS-1 was present in both cytosolic and membrane fractions including purified chromaffin granules, and in immunofluorescence, its distribution overlapped with peripheral punctate staining seen with the synaptic-like microvesicle marker synaptophysin in PC12 cells. The possible functional role of NCS-1 in exocytosis of dense-core granules was tested using transient transfection in PC12 cells and assay of co-transfected growth hormone (GH) release. Overexpression of NCS-1 increased evoked GH release in intact cells in response to ATP. No effect of overexpression was seen on GH release because of Ca2+ in permeabilized cells suggesting that NCS-1 may have a regulatory but not direct role in neurosecretion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synaptotagmin I: A major Ca2+ sensor for transmitter release at a central synapse
Geppert, M., Goda, Y., Hammer, R. E., Li, C., Rosahl, T. W., Stevens, C. F., & Südhof, T. C. (1994) · Cell · doi:10.1016/0092-8674(94)90556-8 · Cited by 1,483
Rim is a putative Rab3 effector in regulating synaptic-vesicle fusion
Wang, Y., Okamoto, M., Schmitz, F., Hofmann, K., & Südhof, T. C. (1997) · Nature · doi:10.1038/41580 · Cited by 684
Cited by
Calcineurin: Form and Function
Rusnak, F., & Mertz, P. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.4.1483 · Cited by 1,373
Neuronal calcium signaling: function and dysfunction
Brini, M., Calì, T., Ottolini, D., & Carafoli, E. (2014) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-013-1550-7 · Cited by 748
Neuronal calcium sensor proteins: generating diversity in neuronal Ca2+ signalling
Burgoyne, R. D. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2093 · Cited by 527
Self-citationRopers, H.-H., & Hamel, B. C. J. (2005) · Nature Reviews Genetics · doi:10.1038/nrg1501 · Cited by 501
The neuronal calcium sensor family of Ca2+-binding proteins
BURGOYNE, R. D., & WEISS, J. L. (2001) · Biochemical Journal · doi:10.1042/bj3530001 · Cited by 444
Self-citation
Metadata
- Authors
- McFerran, B. W., Graham, M. E., & Burgoyne, R. D.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1998-08
- Volume
- 273
- Issue
- 35
- Pages
- 22768-22772
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W2051746145
- Cited by
- 149
- References
- 2
- FWCI
- 4.33
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.