Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 279

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

A Novel Method for Measurement of Submembrane ATP Concentration

Open access
Gribble, Fiona M., Loussouarn, Gildas, Tucker, Stephen J., Zhao, Chao, Nichols, Colin G., Ashcroft, Frances M. · 2000 · Journal of Biological Chemistry

Abstract

There has been considerable debate as to whether adenosine triphosphate (ATP) is compartmentalized within cells and, in particular, whether the ATP concentration directly beneath the plasma membrane, experienced by membrane proteins, is the same as that of the bulk cytoplasm. This issue has been difficult to address because there is no indicator of cytosolic ATP, such as those available for Ca(2+), capable of resolving the submembrane ATP concentration ([ATP](sm)) in real time within a single cell. We show here that mutant ATP-sensitive K(+) channels can be used to measure [ATP](sm) by comparing the increase in current amplitude on patch excision with the ATP dose-response curve. In Xenopus oocytes, [ATP](sm) was 4.6 +/- 0.3 mm (n = 29) under resting conditions, slightly higher than that measured for the bulk cytoplasm (2.3 mm). In mammalian (COSm6) cells, [ATP](sm) was slightly lower and averaged 1.4 +/- 0.1 mm (n = 66). Metabolic poisoning (10 min of 3 mm azide) produced a significant fall in [ATP](sm) in both types of cells: to 1.2 +/- 0.1 mm (n = 24) in oocytes and 0.8 +/- 0.11 mm for COSm6 cells. We conclude that [ATP](sm) lies in the low millimolar range and that there is no gradient between bulk cytosolic and submembrane [ATP].

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1074/jbc.m001010200

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 279

Metadata

Authors
Gribble, F. M., Loussouarn, G., Tucker, S. J., Zhao, C., Nichols, C. G., & Ashcroft, F. M.
Venue
Journal of Biological Chemistry
Publisher
Elsevier BV
Published
2000-09
Volume
275
Issue
39
Pages
30046-30049
ISSN
0021-9258 (ISSN-L)
OpenAlex
W2109971160
Cited by
279
References
29
FWCI
2.25
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Method for Measurement of Submembrane ATP Concentration. https://app.cochat.ai/papers/10.1074/jbc.m001010200
The paper
Gribble, F. M., Loussouarn, G., Tucker, S. J., Zhao, C., Nichols, C. G., & Ashcroft, F. M. (2000). A Novel Method for Measurement of Submembrane ATP Concentration. Journal of Biological Chemistry. https://doi.org/10.1074/jbc.m001010200

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.