Ion Mobility Tandem Mass Spectrometry Enhances Performance of Bottom-up Proteomics
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
One of the limiting factors in determining the sensitivity of tandem mass spectrometry using hybrid quadrupole orthogonal acceleration time-of-flight instruments is the duty cycle of the orthogonal ion injection system. As a consequence, only a fraction of the generated fragment ion beam is collected by the time-of-flight analyzer. Here we describe a method utilizing postfragmentation ion mobility spectrometry of peptide fragment ions in conjunction with mobility time synchronized orthogonal ion injection leading to a substantially improved duty cycle and a concomitant improvement in sensitivity of up to 10-fold for bottom-up proteomic experiments. This enabled the identification of 7500 human proteins within 1 day and 8600 phosphorylation sites within 5 h of LC-MS/MS time. The method also proved powerful for multiplexed quantification experiments using tandem mass tags exemplified by the chemoproteomic interaction analysis of histone deacetylases with Trichostatin A.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Semi-supervised learning for peptide identification from shotgun proteomics datasets
Käll, L., Canterbury, J. D., Weston, J., Noble, W. S., & MacCoss, M. J. (2007) · Nature Methods · doi:10.1038/nmeth1113 · Cited by 2,424
ProteoWizard: open source software for rapid proteomics tools development
Kessner, D., Chambers, M., Burke, R., Agus, D., & Mallick, P. (2008) · Bioinformatics · doi:10.1093/bioinformatics/btn323 · Cited by 2,024
The Proteomics Identifications (PRIDE) database and associated tools: status in 2013
Vizcaíno, J. A., Côté, R. G., Csordas, A., Dianes, J. A., Fabregat, A., Foster, J. M., Griss, J., Alpi, E., Birim, M., Contell, J., et al. (2012) · Nucleic Acids Research · doi:10.1093/nar/gks1262 · Cited by 1,918
Michalski, A., Cox, J., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr101060v · Cited by 685
Chemoproteomics profiling of HDAC inhibitors reveals selective targeting of HDAC complexes
Bantscheff, M., Hopf, C., Savitski, M. M., Dittmann, A., Grandi, P., Michon, A.-M., Schlegl, J., Abraham, Y., Becher, I., Bergamini, G., et al. (2011) · Nature Biotechnology · doi:10.1038/nbt.1759 · Cited by 659 · cited 2×
“reported before (19), SAHA beads capture HDACs class I”
BackgroundMethodSelf-citationWiśniewski, J. R., Zougman, A., & Mann, M. (2009) · Journal of Proteome Research · doi:10.1021/pr900748n · Cited by 545 · cited 1×
“, Madison, WI) according to the FASP protocol (15).”
Hebert, A. S., Richards, A. L., Bailey, D. J., Ulbrich, A., Coughlin, E. E., Westphall, M. S., & Coon, J. J. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.034769 · Cited by 528
Rapid and Deep Human Proteome Analysis by Single-dimension Shotgun Proteomics
Pirmoradian, M., Budamgunta, H., Chingin, K., Zhang, B., Astorga-Wells, J., & Zubarev, R. A. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o113.028787 · Cited by 144
Cited by
Meier, F., Brunner, A.-D., Koch, S., Koch, H., Lubeck, M., Krause, M., Goedecke, N., Decker, J., Kosinski, T., Park, M. A., et al. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir118.000900 · Cited by 965
diaPASEF: parallel accumulation–serial fragmentation combined with data-independent acquisition
Meier, F., Brunner, A.-D., Frank, M., Ha, A., Bludau, I., Voytik, E., Kaspar-Schoenefeld, S., Lubeck, M., Raether, O., Bache, N., et al. (2020) · Nature Methods · doi:10.1038/s41592-020-00998-0 · Cited by 897
A Scalable Approach for Protein False Discovery Rate Estimation in Large Proteomic Data Sets
Savitski, M. M., Wilhelm, M., Hahne, H., Kuster, B., & Bantscheff, M. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.046995 · Cited by 445
Self-citationMeier, F., Beck, S., Grassl, N., Lubeck, M., Park, M. A., Raether, O., & Mann, M. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00932 · Cited by 423
Trapped ion mobility spectrometry: A short review
Ridgeway, M. E., Lubeck, M., Jordens, J., Mann, M., & Park, M. A. (2018) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2018.01.006 · Cited by 308
MaxQuant Software for Ion Mobility Enhanced Shotgun Proteomics
Prianichnikov, N., Koch, H., Koch, S., Lubeck, M., Heilig, R., Brehmer, S., Fischer, R., & Cox, J. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir119.001720 · Cited by 189
“Together with liquid chromatography (LC) and tandem mass spectrometry (MS/MS) one obtains LC-IMS-MS/MS shotgun proteomics, a promising strategy for the analysis of complex samples (4–7).”
Adding a new separation dimension to MS and LC–MS: What is the utility of ion mobility spectrometry?
D'Atri, V., Causon, T., Hernandez‐Alba, O., Mutabazi, A., Veuthey, J., Cianferani, S., & Guillarme, D. (2018) · Journal of Separation Science · doi:10.1002/jssc.201700919 · Cited by 184
Trapped Ion Mobility Spectrometry and Parallel Accumulation–Serial Fragmentation in Proteomics
Meier, F., Park, M. A., & Mann, M. (2021) · Molecular & Cellular Proteomics · doi:10.1016/j.mcpro.2021.100138 · Cited by 183
Dietary- and host-derived metabolites are used by diverse gut bacteria for anaerobic respiration
Little, A. S., Younker, I. T., Schechter, M. S., Bernardino, P. N., Méheust, R., Stemczynski, J., Scorza, K., Mullowney, M. W., Sharan, D., Waligurski, E., et al. (2024) · Nature Microbiology · doi:10.1038/s41564-023-01560-2 · Cited by 80
Ion mobility in the pharmaceutical industry: an established biophysical technique or still niche?
Campuzano, I. D., & Lippens, J. L. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2017.11.008 · Cited by 42
Structure of mycobacterial respiratory complex I
Liang, Y., Plourde, A., Bueler, S. A., Liu, J., Brzezinski, P., Vahidi, S., & Rubinstein, J. L. (2023) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2214949120 · Cited by 31
An alphaherpesvirus exploits antimicrobial β-Defensins to initiate respiratory tract infection.
Van Cleemput, J., Poelaert, K. C. K., Laval, K., Vanderheijden, N., Dhaenens, M., Daled, S., Boyen, F., Pasmans, F., & Nauwynck, H. J. (2020) · Journal of Virology · doi:10.1128/jvi.01676-19 · Cited by 13
Xian, F., Sondermann, J. R., Gomez Varela, D., & Schmidt, M. (2022) · eLife · doi:10.7554/elife.81431 · Cited by 13
Metadata
- Authors
- Helm, D., Vissers, J. P. C., Hughes, C. J., Hahne, H., Ruprecht, B., Pachl, F., Grzyb, A., Richardson, K., Wildgoose, J., Maier, S. K., Marx, H., Wilhelm, M., Becher, I., Lemeer, S., Bantscheff, M., Langridge, J. I., & Kuster, B.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2014-12
- Volume
- 13
- Issue
- 12
- Pages
- 3709-3715
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2142821301
- Cited by
- 111
- References
- 8
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.