A Method for Automatically Interpreting Mass Spectra of 18O-Labeled Isotopic Clusters
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
16O/18O labeling is one differential proteomics technology among many that promises diagnostic and prognostic biomarkers of disease. Although the incorporation of 18O in the C-terminal carboxyl group during endoproteinase digestion in the presence of H2 18O makes the process of labeling facile, the ease and effectiveness of label incorporation have in some regards been outweighed by the difficulties in interpreting the resulting spectra. Complex isotope patterns result from the composition of unlabeled (18O(0)), singly labeled (18O(1)), and doubly labeled species (18O(2)) as well as contributions from the naturally occurring isotopes (e.g. 13C and 15N). Moreover because labeling is enzymatic, the number of 18O atoms incorporated can vary from peptide to peptide. Finally it is difficult to distinguish highly up-regulated from highly down-regulated or C-terminal peptides. We have developed an algorithm entitled regression analysis applied to mass spectrometry (RAAMS) that automatically, rapidly, and confidently interprets spectra of 18O-labeled peptides without requiring chemical composition information derived from product ion spectra. The algorithm is able to measure the effective 18O incorporation rate due to variable enzyme substrate specificity of the pseudosubstrate during the isotope exchange reaction and corrects for the 18O(0) abundance that remains in the labeled sample when using a two-step digestion/labeling procedure. We have also incorporated a method for distinguishing pure 18O(0) from pure 18O(2) peptides utilizing impure H2 18O. The algorithm operates on centroided peak lists and is therefore very fast: nine chromatograms of, on average, 1,168 spectra and containing, on average, 6,761 isotopic clusters were interpreted in, on average, 45 s per chromatogram. RAAMS is fast enough (average, 38 ms/spectrum) to allow the possibility of performing information-dependent MS/MS on a chromatographic time scale on species exceeding predetermined ratio thresholds. We describe in detail the operation of the algorithm and demonstrate its use on datasets with known and unknown ratios.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Ross, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401
Automated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451 · cited 2×
“Step 2: For each potential isotope cluster: a) Form a matrix X with theoretical isotopic abundances, generated using averagine (16) and Mercury (22), for incorporation of 0, 1, or 2 (18)O atoms.”
Method
Cited by
In-gel digestion for mass spectrometric characterization of proteins and proteomes
Shevchenko, A., Tomas, H., Havli, J., Olsen, J. V., & Mann, M. (2006) · Nature Protocols · doi:10.1038/nprot.2006.468 · Cited by 4,942
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Statistical Analysis of Relative Labeled Mass Spectrometry Data from Complex Samples Using ANOVA
Oberg, A. L., Mahoney, D. W., Eckel-Passow, J. E., Malone, C. J., Wolfinger, R. D., Hill, E. G., Cooper, L. T., Onuma, O. K., Spiro, C., Therneau, T. M., et al. (2008) · Journal of Proteome Research · doi:10.1021/pr700734f · Cited by 192
“protein/peptide abundances(4, 6, 7 ). The iTRAQ™ labeling system overcomes this to some extent since”
BackgroundSelf-citationDeconvolution and Database Search of Complex Tandem Mass Spectra of Intact Proteins
Liu, X., Inbar, Y., Dorrestein, P. C., Wynne, C., Edwards, N., Souda, P., Whitelegge, J. P., Bafna, V., & Pevzner, P. A. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.002766 · Cited by 170
Jaleel, A., Klaus, K. A., Morse, D. M., Karakelides, H., Ward, L. E., Irving, B. A., & Nair, K. S. (2009) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00351.2009 · Cited by 23
Self-citation
Metadata
- Authors
- Mason, C. J., Therneau, T. M., Eckel-Passow, J. E., Johnson, K. L., Oberg, A. L., Olson, J. E., Nair, K. S., Muddiman, D. C., & Bergen, H. R.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2007-02
- Volume
- 6
- Issue
- 2
- Pages
- 305-318
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2122545105
- Cited by
- 61
- References
- 4
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Method for Automatically Interpreting Mass Spectra of 18O-Labeled Isotopic Clusters. https://app.cochat.ai/papers/10.1074/mcp.m600148-mcp200
- The paper
- Mason, C. J., Therneau, T. M., Eckel-Passow, J. E., Johnson, K. L., Oberg, A. L., Olson, J. E., Nair, K. S., Muddiman, D. C., & Bergen, H. R. (2007). A Method for Automatically Interpreting Mass Spectra of 18O-Labeled Isotopic Clusters. Molecular & Cellular Proteomics. https://doi.org/10.1074/mcp.m600148-mcp200
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.