Robust and Sensitive iTRAQ Quantification on an LTQ Orbitrap Mass Spectrometer
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Isobaric stable isotope tagging reagents such as tandem mass tags or isobaric tags for relative and absolute quantification enable multiplexed quantification of peptides via reporter ion signals in the low mass range of tandem mass spectra. Until recently, the poor recovery of low mass fragments observed in tandem mass spectra acquired on ion trap mass spectrometers precluded the use of these reagents on this widely available instrument platform. The Pulsed Q Dissociation (PQD) technique allows negotiating this limitation but suffers from poor fragmentation efficiency, which has raised doubts in the community as to its practical utility. Here we show that by carefully optimizing instrument parameters such as collision energy, activation Q, delay time, ion isolation width, number of microscans, and number of trapped ions, low m/z fragment ion intensities can be generated that enable accurate peptide quantification at the 100 amol level. Side by side comparison of PQD on an LTQ Orbitrap with CID on a five-year old Q-Tof Ultima using complex protein digests shows that whereas precision of quantification of 10-15% can be achieved by both approaches, PQD quantifies twice as many proteins. PQD on an LTQ Orbitrap also outperforms "higher energy collision induced dissociation" on the same instrument using the recently introduced octapole collision cell in terms of lower limit of quantification. Finally, we demonstrate the significant analytical potential of iTRAQ quantification using PQD on an LTQ Orbitrap by quantitatively measuring the kinase interaction profile of the small molecule drug imatinib in K-562 cells. This article gives practical guidance for the implementation of PQD, discusses its merits, and for the first time, compares its performance to higher energy collision-induced dissociation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ong, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Ross, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401 · cited 1×
“(12) have emerged, which allow the introduction of 4–8 different mass labels into peptides with a concomitant increase in the number of conditions that can be compared in one experiment.”
BackgroundElias, J. E., & Gygi, S. P. (2007) · Nature Methods · doi:10.1038/nmeth1019 · Cited by 3,925 · cited 1×
“We searched an in-house curate version of the human International Protein Index database combined with a decoy version thereof (21).”
MethodThompson, A., Schäfer, J., Kuhn, K., Kienle, S., Schwarz, J., Schmidt, G., Neumann, T., & Hamon, C. (2003) · Analytical Chemistry · doi:10.1021/ac0262560 · Cited by 2,378 · cited 1×
“As an alternative, isobaric labeling techniques such as tandem mass tags, (11) and isobaric tags for relative and absolute quantification (iTRAQ)(1)”
MethodAbsolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832254100 · Cited by 1,733
Quantitative mass spectrometry in proteomics: a critical review
Bantscheff, M., Schirle, M., Sweetman, G., Rick, J., & Kuster, B. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1486-6 · Cited by 1,669 · cited 1×
“Quantitative measurements are becoming increasingly important in proteomics, and a multitude of mass spectrometrybased methods have been developed for this purpose over the past few years (recently reviewed by Bantscheff et al. ( 1 ) and Ong and Mann (2)).”
MethodSelf-citationMass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572 · cited 1×
“Quantitative measurements are becoming increasingly important in proteomics, and a multitude of mass spectrometrybased methods have been developed for this purpose over the past few years (recently reviewed by Bantscheff et al. (1) and Ong and Mann ( 2 )).”
BackgroundOlsen, J. V., de Godoy, L. M. F., Li, G., Macek, B., Mortensen, P., Pesch, R., Makarov, A., Lange, O., Horning, S., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500030-mcp200 · Cited by 1,510 · cited 1×
“Internal calibration was performed using the ion signal of (Si(CH3)2O)6H at m/z 445.120025 as a lock mass ( 20 ).”
MethodInfluentialQuantitative chemical proteomics reveals mechanisms of action of clinical ABL kinase inhibitors
Bantscheff, M., Eberhard, D., Abraham, Y., Bastuck, S., Boesche, M., Hobson, S., Mathieson, T., Perrin, J., Raida, M., Rau, C., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1328 · Cited by 1,034 · cited 6×
“Tryptic in-gel digestion, iTRAQ labeling, and phosphopeptide enrichment was done as described (18).”
MethodInfluentialSelf-citation
Cited by
Tankyrase inhibition stabilizes axin and antagonizes Wnt signalling
Huang, S.-M. A., Mishina, Y. M., Liu, S., Cheung, A., Stegmeier, F., Michaud, G. A., Charlat, O., Wiellette, E., Zhang, Y., Wiessner, S., et al. (2009) · Nature · doi:10.1038/nature08356 · Cited by 2,037
McAlister, G. C., Nusinow, D. P., Jedrychowski, M. P., Wühr, M., Huttlin, E. L., Erickson, B. K., Rad, R., Haas, W., & Gygi, S. P. (2014) · Analytical Chemistry · doi:10.1021/ac502040v · Cited by 1,263
MS3 eliminates ratio distortion in isobaric multiplexed quantitative proteomics
Ting, L., Rad, R., Gygi, S. P., & Haas, W. (2011) · Nature Methods · doi:10.1038/nmeth.1714 · Cited by 1,009
Revisiting biomarker discovery by plasma proteomics
Geyer, P. E., Holdt, L. M., Teupser, D., & Mann, M. (2017) · Molecular Systems Biology · doi:10.15252/msb.20156297 · Cited by 917
“Quantification is achieved by fragmenting peptides and quantifying the relative ratios of the reporter ions (Bantscheff et al, 2008).”
BackgroundQuantitative mass spectrometry in proteomics: critical review update from 2007 to the present
Bantscheff, M., Lemeer, S., Savitski, M. M., & Kuster, B. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6203-4 · Cited by 801
Self-citationChemoproteomics profiling of HDAC inhibitors reveals selective targeting of HDAC complexes
Bantscheff, M., Hopf, C., Savitski, M. M., Dittmann, A., Grandi, P., Michon, A.-M., Schlegl, J., Abraham, Y., Becher, I., Bergamini, G., et al. (2011) · Nature Biotechnology · doi:10.1038/nbt.1759 · Cited by 659
“The reduction in protein capture that resulted from inhibitor treatment was quantified by isobaric tagging of tryptic peptides and tandem mass spectrometry analysis (MS/MS) of the combined peptide pool”
MethodSelf-citationSilencing of microRNA families by seed-targeting tiny LNAs
Obad, S., dos Santos, C. O., Petri, A., Heidenblad, M., Broom, O., Ruse, C., Fu, C., Lindow, M., Stenvang, J., Straarup, E. M., et al. (2011) · Nature Genetics · doi:10.1038/ng.786 · Cited by 627
Isobaric Labeling-Based Relative Quantification in Shotgun Proteomics
Rauniyar, N., & Yates, J. R. (2014) · Journal of Proteome Research · doi:10.1021/pr500880b · Cited by 596
Addressing Accuracy and Precision Issues in iTRAQ Quantitation
Karp, N. A., Huber, W., Sadowski, P. G., Charles, P. D., Hester, S. V., & Lilley, K. S. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900628-mcp200 · Cited by 495
iTRAQ Underestimation in Simple and Complex Mixtures: “The Good, the Bad and the Ugly”
Ow, S. Y., Salim, M., Noirel, J., Evans, C., Rehman, I., & Wright, P. C. (2009) · Journal of Proteome Research · doi:10.1021/pr900634c · Cited by 489
Global and Site-Specific Quantitative Phosphoproteomics: Principles and Applications
Macek, B., Mann, M., & Olsen, J. V. (2009) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev.pharmtox.011008.145606 · Cited by 386
Quantitative Proteomic Analysis of Histone Modifications
Huang, H., Lin, S., Garcia, B. A., & Zhao, Y. (2015) · Chemical Reviews · doi:10.1021/cr500491u · Cited by 370
Quantitation in Mass-Spectrometry-Based Proteomics
Schulze, W. X., & Usadel, B. (2010) · Annual Review of Plant Biology · doi:10.1146/annurev-arplant-042809-112132 · Cited by 344
An insight into iTRAQ: where do we stand now?
Evans, C., Noirel, J., Ow, S. Y., Salim, M., Pereira-Medrano, A. G., Couto, N., Pandhal, J., Smith, D., Pham, T. K., Karunakaran, E., et al. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5918-6 · Cited by 300
Measuring and Managing Ratio Compression for Accurate iTRAQ/TMT Quantification
Savitski, M. M., Mathieson, T., Zinn, N., Sweetman, G., Doce, C., Becher, I., Pachl, F., Kuster, B., & Bantscheff, M. (2013) · Journal of Proteome Research · doi:10.1021/pr400098r · Cited by 276
Self-citationStable isotope labelling methods in mass spectrometry-based quantitative proteomics
Chahrour, O., Cobice, D., & Malone, J. (2015) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2015.04.013 · Cited by 267
Performance Evaluation of the Q Exactive HF-X for Shotgun Proteomics
Kelstrup, C. D., Bekker-Jensen, D. B., Arrey, T. N., Hogrebe, A., Harder, A., & Olsen, J. V. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00602 · Cited by 254
Senko, M. W., Remes, P. M., Canterbury, J. D., Mathur, R., Song, Q., Eliuk, S. M., Mullen, C., Earley, L., Hardman, M., Blethrow, J. D., et al. (2013) · Analytical Chemistry · doi:10.1021/ac403115c · Cited by 243
Cancer proteogenomics: current impact and future prospects
Mani, D. R., Krug, K., Zhang, B., Satpathy, S., Clauser, K. R., Ding, L., Ellis, M., Gillette, M. A., & Carr, S. A. (2022) · Nature Reviews Cancer · doi:10.1038/s41568-022-00446-5 · Cited by 229
Ray, S., Reddy, P. J., Jain, R., Gollapalli, K., Moiyadi, A., & Srivastava, S. (2011) · PROTEOMICS · doi:10.1002/pmic.201000460 · Cited by 224
General Statistical Framework for Quantitative Proteomics by Stable Isotope Labeling
Navarro, P., Trevisan-Herraz, M., Bonzon-Kulichenko, E., Núñez, E., Martínez-Acedo, P., Pérez-Hernández, D., Jorge, I., Mesa, R., Calvo, E., Carrascal, M., et al. (2014) · Journal of Proteome Research · doi:10.1021/pr4006958 · Cited by 217
Keshishian, H., Burgess, M. W., Specht, H., Wallace, L., Clauser, K. R., Gillette, M. A., & Carr, S. A. (2017) · Nature Protocols · doi:10.1038/nprot.2017.054 · Cited by 190
iTRAQ Labeling is Superior to mTRAQ for Quantitative Global Proteomics and Phosphoproteomics
Mertins, P., Udeshi, N. D., Clauser, K. R., Mani, D., Patel, J., Ong, S.-E., Jaffe, J. D., & Carr, S. A. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.014423 · Cited by 190
“as pulsed-Q dissociation (15) and alternating CID/HCD scans”
Pichler, P., Köcher, T., Holzmann, J., Mazanek, M., Taus, T., Ammerer, G., & Mechtler, K. (2010) · Analytical Chemistry · doi:10.1021/ac100890k · Cited by 175
Erickson, B. K., Jedrychowski, M. P., McAlister, G. C., Everley, R. A., Kunz, R., & Gygi, S. P. (2015) · Analytical Chemistry · doi:10.1021/ac503934f · Cited by 159
Wang, H., Alvarez, S., & Hicks, L. M. (2012) · Journal of Proteome Research · doi:10.1021/pr2008225 · Cited by 142
Niu, M., Cho, J.-H., Kodali, K., Pagala, V., High, A. A., Wang, H., Wu, Z., Li, Y., Bi, W., Zhang, H., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04415 · Cited by 118
Seyfried, N. T., Gozal, Y. M., Donovan, L. E., Herskowitz, J. H., Dammer, E. B., Xia, Q., Ku, L., Chang, J., Duong, D. M., Rees, H. D., et al. (2012) · Journal of Proteome Research · doi:10.1021/pr2010814 · Cited by 64
“pulsed Q collision induced dissociation (PQD) to sufficiently balance backbone precursor ion fragmentation and maintain reporter ion intensity for accurate quantitative measurements [12, 13].”
BackgroundYugandhar, K., Gupta, S., & Yu, H. (2019) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2019.05.007 · Cited by 51
Improved Proteomics-Based Drug Mechanism-of-Action Studies Using 16-Plex Isobaric Mass Tags
Zinn, N., Werner, T., Doce, C., Mathieson, T., Boecker, C., Sweetman, G., Fufezan, C., & Bantscheff, M. (2021) · Journal of Proteome Research · doi:10.1021/acs.jproteome.0c00900 · Cited by 49
Self-citation
Metadata
- Authors
- Bantscheff, M., Boesche, M., Eberhard, D., Matthieson, T., Sweetman, G., & Kuster, B.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2008-09
- Volume
- 7
- Issue
- 9
- Pages
- 1702-1713
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2139208986
- Cited by
- 235
- References
- 19
- FWCI
- 11.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.