SISCAPA Peptide Enrichment on Magnetic Beads Using an In-line Bead Trap Device
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A SISCAPA (stable isotope standards and capture by anti-peptide antibodies) method for specific antibody-based capture of individual tryptic peptides from a digest of whole human plasma was developed using a simplified magnetic bead protocol and a novel rotary magnetic bead trap device. Following off-line equilibrium binding of peptides by antibodies and subsequent capture of the antibodies on magnetic beads, the bead trap permitted washing of the beads and elution of bound peptides inside a 150-microm-inner diameter capillary that forms part of a nanoflow LC-MS/MS system. The bead trap sweeps beads against the direction of liquid flow using a continuous succession of moving high magnetic field-gradient trap regions while mixing the beads with the flowing liquid. This approach prevents loss of low abundance captured peptides and allows automated processing of a series of SISCAPA reactions. Selected tryptic peptides of alpha(1)-antichymotrypsin and lipopolysaccharide-binding protein were enriched relative to a high abundance serum albumin peptide by 1,800 and 18,000-fold, respectively, as measured by multiple reaction monitoring. A large majority of the peptides that are bound nonspecifically in SISCAPA reactions were shown to bind to components other than the antibody (e.g. the magnetic beads), suggesting that substantial improvement in enrichment could be achieved by development of improved inert bead surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
Anderson, L., & Hunter, C. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500331-mcp200 · Cited by 1,230 · cited 3×
“The lower cutoff for detecting proteins in a digest of unfractionated plasma by this approach appears to be in the neighborhood of 1–20 g/ml plasma concentration, which would restrict analysis to the top 100 or so proteins in plasma (1).”
BackgroundMethodInfluentialPieper, R., Su, Q., Gatlin, C. L., Huang, S., Anderson, N. L., & Steiner, S. (2003) · PROTEOMICS · doi:10.1002/pmic.200390057 · Cited by 356
Self-citation
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
The fundamental flaws of immunoassays and potential solutions using tandem mass spectrometry
Hoofnagle, A. N., & Wener, M. H. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.06.003 · Cited by 561
Proc, J. L., Kuzyk, M. A., Hardie, D. B., Yang, J., Smith, D. S., Jackson, A. M., Parker, C. E., & Borchers, C. H. (2010) · Journal of Proteome Research · doi:10.1021/pr100656u · Cited by 353
Self-citationSweetening the Pot: Adding Glycosylation to the Biomarker Discovery Equation
Drake, P. M., Cho, W., Li, B., Prakobphol, A., Johansen, E., Anderson, N. L., Regnier, F. E., Gibson, B. W., & Fisher, S. J. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.136333 · Cited by 302
Self-citationCurrent trends in quantitative proteomics
Elliott, M. H., Smith, D. S., Parker, C. E., & Borchers, C. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1692 · Cited by 271
Self-citationAdvances in human proteomics at high scale with the SOMAscan proteomics platform
Gold, L., Walker, J. J., Wilcox, S. K., & Williams, S. (2012) · New Biotechnology · doi:10.1016/j.nbt.2011.11.016 · Cited by 261
Bioanalytical LC–MS/MS of protein-based biopharmaceuticals
van den Broek, I., Niessen, W. M. A., & van Dongen, W. D. (2013) · Journal of Chromatography B · doi:10.1016/j.jchromb.2013.04.030 · Cited by 232
LC–MS/MS for protein and peptide quantification in clinical chemistry
Rauh, M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.09.030 · Cited by 171
Boja, E. S., & Rodriguez, H. (2012) · PROTEOMICS · doi:10.1002/pmic.201100387 · Cited by 164
“Additionally, the coupling of SISCAPA to magnetic bead-handling robotics during assay workflow can significantly improve throughput and reproducibility [57, 58].”
MethodSpinning magnetic trap for automated microfluidic assay systems
Verbarg, J., Kamgar-Parsi, K., Shields, A. R., Howell, P. B., & Ligler, F. S. (2012) · Lab on a Chip · doi:10.1039/c2lc21189k · Cited by 39
Rezeli, M., Végvári, Á., Donnarumma, F., Gidlöf, O., Smith, J. G., Erlinge, D., & Marko-Varga, G. (2013) · Journal of Proteomics · doi:10.1016/j.jprot.2013.05.016 · Cited by 33
Metadata
- Authors
- Anderson, N. L., Jackson, A., Smith, D., Hardie, D., Borchers, C., & Pearson, T. W.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2009-05
- Volume
- 8
- Issue
- 5
- Pages
- 995-1005
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2141627904
- Cited by
- 141
- References
- 2
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.