Spinning magnetic trap for automated microfluidic assay systems
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
While sophisticated analyses have been performed using lab-on-chip devices, in most cases the sample preparation is still performed off chip. The global need for easy-to-use, disposable testing devices necessitates that sample processing is automated and that transport complexity between the processing and analytical components is minimal. We describe a complete sample manipulation unit for performing automated target capture, efficient mixing with reagents, and controlled target release in a microfluidic channel, using an array of spinning magnets. The "MagTrap" device consists of 6 pairs of magnets in a rotating wheel, situated immediately beneath the microchannel. Rotation of the wheel in the direction opposite to the continuous flow entraps and concentrates the bead-target complexes and separates them from the original sample matrix. As the wheel rotates and the active pair of magnets moves away from the microchannel, the beads are released and briefly flow downstream before being trapped and pulled upstream by the next pair of magnets. This dynamic and continuous movement of the beads ensures that the full surface area of each bead is exposed to reagents and prevents aggregation. The release of the target-bead complexes for further analysis is facilitated by reversing the rotational direction of the wheel to sweep the beads downstream. Sample processing with the MagTrap was demonstrated for the detection of E. coli in a range of concentrations (1 × 10(3), 1 × 10(4) and 1 × 10(6) cells ml(-1)). Results show that sample processing with the MagTrap outperformed the standard manual protocols, improving the detection capability while simultaneously reducing the processing time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“There are some challenges for microfluidic magnetic separation platforms due to the magnetic beads aggregated in a microchannel using a fixed magnet.23 The aggregation of magnetic beads is not fully exposed to the reagent and affects the flow of the microchannel fluid, which results in the reduction of the efficiency of cell separation.”
From Dynamic Halbach array magnet integrated microfluidic system for the continuous-flow separation of rare tumor cells (2019) · cites this paper as [23]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Continuous sorting of magnetic cells via on-chip free-flow magnetophoresis
Pamme, N., & Wilhelm, C. (2006) · Lab on a Chip · doi:10.1039/b604542a · Cited by 497
On-Chip Free-Flow Magnetophoresis: Continuous Flow Separation of Magnetic Particles and Agglomerates
Pamme, N., & Manz, A. (2004) · Analytical Chemistry · doi:10.1021/ac049183o · Cited by 475
Biomedical applications of distally controlled magnetic nanoparticles
Corchero, J. L., & Villaverde, A. (2009) · Trends in Biotechnology · doi:10.1016/j.tibtech.2009.04.003 · Cited by 281
Sung Kim, K., & Park, J.-K. (2005) · Lab on a Chip · doi:10.1039/b502225h · Cited by 217
Multi-wavelength microflow cytometer using groove-generated sheath flow
Golden, J. P., Kim, J. S., Erickson, J. S., Hilliard, L. R., Howell, P. B., Anderson, G. P., Nasir, M., & Ligler, F. S. (2009) · Lab on a Chip · doi:10.1039/b822442k · Cited by 159
Self-citationSample preconcentration in microfluidic devices
Lin, C.-C., Hsu, J., & Lee, G. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0661-9 · Cited by 145
SISCAPA Peptide Enrichment on Magnetic Beads Using an In-line Bead Trap Device
Anderson, N. L., Jackson, A., Smith, D., Hardie, D., Borchers, C., & Pearson, T. W. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800446-mcp200 · Cited by 141
Multiplexed Detection of Bacteria and Toxins Using a Microflow Cytometer
Kim, J. S., Anderson, G. P., Erickson, J. S., Golden, J. P., Nasir, M., & Ligler, F. S. (2009) · Analytical Chemistry · doi:10.1021/ac9005827 · Cited by 108
Self-citationMobile magnetic particles as solid-supports for rapid surface-based bioanalysis in continuous flow
Peyman, S. A., Iles, A., & Pamme, N. (2009) · Lab on a Chip · doi:10.1039/b904724g · Cited by 99
Research works printed but not linked: 3
- Memisevic J Shriver-Lake LC Howell PB Golden JP Hashemi N Jackson KB Ligler FS BioPhotonics 2011 1 3 2011 International Workshop on, IEEE
- Taitt CR Shriver-Lake LC Anderson GP Ligler FS Hurst SJJ Biomedical Nanotechnology 2011 vol. 726 77 94 Humana Press
- Corporation L xMAP Technology Technical Note 2010
Cited by
Sulfur and Its Role In Modern Materials Science
Boyd, D. A. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201604615 · Cited by 512
Lab on a chip for continuous-flow magnetic cell separation
Hejazian, M., Li, W., & Nguyen, N.-T. (2015) · Lab on a Chip · doi:10.1039/c4lc01422g · Cited by 347
Microfluidics Based Magnetophoresis: A Review
Alnaimat, F., Dagher, S., Mathew, B., Hilal‐Alnqbi, A., & Khashan, S. (2018) · The Chemical Record · doi:10.1002/tcr.201800018 · Cited by 166
Recent advances and current challenges in magnetophoresis based micro magnetofluidics
Munaz, A., Shiddiky, M. J. A., & Nguyen, N.-T. (2018) · Biomicrofluidics · doi:10.1063/1.5035388 · Cited by 164
Recent advances in manipulation of micro- and nano-objects with magnetic fields at small scales
Cao, Q., Fan, Q., Chen, Q., Liu, C., Han, X., & Li, L. (2019) · Materials Horizons · doi:10.1039/c9mh00714h · Cited by 160
Metadata
- Authors
- Verbarg, J., Kamgar-Parsi, K., Shields, A. R., Howell, P. B., & Ligler, F. S.
- Affiliations
- United States Naval Research Laboratory (US)
- Corresponding author
- Ligler, Frances S.
- ORCID
- Ligler, Frances S.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 10
- Pages
- 1793
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- PMC
- PMC3641145
- OpenAlex
- W2066940483
- Cited by
- 39
- References
- 27
- Citations by year
- 2024: 2 · 2022: 1 · 2021: 1 · 2020: 2 · 2019: 5 · 2018: 3 · 2017: 2 · 2016: 8 · 2015: 3 · 2014: 7 · 2013: 3 · 2012: 2
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- Defense Threat Reduction Agency
- U.S. Public Health Service (U01 A1075489)
- U.S. Navy
- Office of Naval Research
- National Institute of Allergy and Infectious Diseases (U01AI075489)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Keywords
- automated sample preparation, Escherichia coli detection, lab-on-a-chip
- MeSH terms
- Equipment Design, Escherichia coli, Fluorescent Dyes, Immunoglobulin G, Immunoassay, Microspheres, Models, Theoretical, Immunomagnetic Separation, Microfluidic Analytical Techniques, Magnets
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spinning magnetic trap for automated microfluidic assay systems. https://app.cochat.ai/papers/10.1039/c2lc21189k
- The paper
- Verbarg, J., Kamgar-Parsi, K., Shields, A. R., Howell, P. B., & Ligler, F. S. (2012). Spinning magnetic trap for automated microfluidic assay systems. Lab on a Chip. https://doi.org/10.1039/c2lc21189k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.