A Novel LC System Embeds Analytes in Pre-formed Gradients for Rapid, Ultra-robust Proteomics
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
To further integrate mass spectrometry (MS)-based proteomics into biomedical research and especially into clinical settings, high throughput and robustness are essential requirements. They are largely met in high-flow rate chromatographic systems for small molecules but these are not sufficiently sensitive for proteomics applications. Here we describe a new concept that delivers on these requirements while maintaining the sensitivity of current nano-flow LC systems. Low-pressure pumps elute the sample from a disposable trap column, simultaneously forming a chromatographic gradient that is stored in a long storage loop. An auxiliary gradient creates an offset, ensuring the re-focusing of the peptides before the separation on the analytical column by a single high-pressure pump. This simplified design enables robust operation over thousands of sample injections. Furthermore, the steps between injections are performed in parallel, reducing overhead time to a few minutes and allowing analysis of more than 200 samples per day. From fractionated HeLa cell lysates, deep proteomes covering more than 130,000 sequence unique peptides and close to 10,000 proteins were rapidly acquired. Using this data as a library, we demonstrate quantitation of 5200 proteins in only 21 min. Thus, the new system - termed Evosep One - analyzes samples in an extremely robust and high throughput manner, without sacrificing in depth proteomics coverage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cox, J., & Mann, M. (2008) · Nature Biotechnology · doi:10.1038/nbt.1511 · Cited by 14,855 · cited 1×
“8) (3) and fragments lists were searched against the human Uniprot Reference Proteome without isoforms (April 2017 release with 21,042 protein sequences) by the Andromeda search engine (25) with cysteine carbamidomethylation as a fixed modification and N-terminal acetylation and methionine oxidations as variable modif…”
MethodSelf-citationThe Perseus computational platform for comprehensive analysis of (prote)omics data
Tyanova, S., Temu, T., Sinitcyn, P., Carlson, A., Hein, M. Y., Geiger, T., Mann, M., & Cox, J. (2016) · Nature Methods · doi:10.1038/nmeth.3901 · Cited by 8,803
Self-citationAndromeda: A Peptide Search Engine Integrated into the MaxQuant Environment
Cox, J., Neuhauser, N., Michalski, A., Scheltema, R. A., Olsen, J. V., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr101065j · Cited by 5,500
Self-citationCox, J., Hein, M. Y., Luber, C. A., Paron, I., Nagaraj, N., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.031591 · Cited by 5,180 · cited 1×
“, 2016) and ‘match between runs’ at the MS level (Cox et al., 2014; Geiger et al., 2012).”
BackgroundSelf-citationSkyline: an open source document editor for creating and analyzing targeted proteomics experiments
MacLean, B., Tomazela, D. M., Shulman, N., Chambers, M., Finney, G. L., Frewen, B., Kern, R., Tabb, D. L., Liebler, D. C., & MacCoss, M. J. (2010) · Bioinformatics · doi:10.1093/bioinformatics/btq054 · Cited by 4,697 · cited 1×
“Skyline was used to extract between 4 and 6 MS2 ions (parallel reaction monitoring) for each of the 8 peptides (23).”
MethodRappsilber, J., Ishihama, Y., & Mann, M. (2003) · Analytical Chemistry · doi:10.1021/ac026117i · Cited by 2,644
Self-citationMass-spectrometric exploration of proteome structure and function
Aebersold, R., & Mann, M. (2016) · Nature · doi:10.1038/nature19949 · Cited by 2,334 · cited 1×
“Bottom-up proteomics is a highly successful and generic technology, which now allows the analysis of complex samples ranging from bacteria through cell line systems and even human tissue samples (1).”
BackgroundSelf-citationKulak, N. A., Pichler, G., Paron, I., Nagaraj, N., & Mann, M. (2014) · Nature Methods · doi:10.1038/nmeth.2834 · Cited by 1,719 · cited 3×
“Protein digestion – For sample preparation we used the iST kit for proteomic samples (Kulak et al., 2014), starting with 10(6) HeLa cells according to the manufacturer’s instructions (P.”
BackgroundMethodInfluentialSelf-citationSelected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions
Picotti, P., & Aebersold, R. (2012) · Nature Methods · doi:10.1038/nmeth.2015 · Cited by 1,302 · cited 1×
“retention times, especially targeted proteomics (10), data in-”
BackgroundTracking cancer drugs in living cells by thermal profiling of the proteome
Savitski, M. M., Reinhard, F. B. M., Franken, H., Werner, T., Savitski, M. F., Eberhard, D., Molina, D. M., Jafari, R., Dovega, R. B., Klaeger, S., et al. (2014) · Science · doi:10.1126/science.1255784 · Cited by 1,187 · cited 1×
“There are several proteomics strategies that produce many fractions, such as thermal shift assays (31) or organellar proteomics (32), and our approach opens up for strategies to rapidly and robustly measure these.”
Background
Cited by
Meier, F., Brunner, A.-D., Koch, S., Koch, H., Lubeck, M., Krause, M., Goedecke, N., Decker, J., Kosinski, T., Park, M. A., et al. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir118.000900 · Cited by 965
Self-citationdiaPASEF: parallel accumulation–serial fragmentation combined with data-independent acquisition
Meier, F., Brunner, A.-D., Frank, M., Ha, A., Bludau, I., Voytik, E., Kaspar-Schoenefeld, S., Lubeck, M., Raether, O., Bache, N., et al. (2020) · Nature Methods · doi:10.1038/s41592-020-00998-0 · Cited by 897
Self-citationOpenCell: Endogenous tagging for the cartography of human cellular organization
Cho, N. H., Cheveralls, K. C., Brunner, A.-D., Kim, K., Michaelis, A. C., Raghavan, P., Kobayashi, H., Savy, L., Li, J. Y., Canaj, H., et al. (2022) · Science · doi:10.1126/science.abi6983 · Cited by 567
Self-citationUltra-High-Throughput Clinical Proteomics Reveals Classifiers of COVID-19 Infection
Messner, C. B., Demichev, V., Wendisch, D., Michalick, L., White, M., Freiwald, A., Textoris-Taube, K., Vernardis, S. I., Egger, A.-S., Kreidl, M., et al. (2020) · Cell Systems · doi:10.1016/j.cels.2020.05.012 · Cited by 561
Ultra‐high sensitivity mass spectrometry quantifies single‐cell proteome changes upon perturbation
Brunner, A., Thielert, M., Vasilopoulou, C., Ammar, C., Coscia, F., Mund, A., Hoerning, O. B., Bache, N., Apalategui, A., Lubeck, M., et al. (2022) · Molecular Systems Biology · doi:10.15252/msb.202110798 · Cited by 544
“For all other proteome analyses, we used an EvoSep One liquid chromatography system (Bache et al , 2018) and analyzed the single-cell proteomes with a novel 35 min stepped pre-formed beta gradient eluting the peptides at 100 nl/min flow rate.”
Self-citationdia-PASEF data analysis using FragPipe and DIA-NN for deep proteomics of low sample amounts
Demichev, V., Szyrwiel, L., Yu, F., Teo, G. C., Rosenberger, G., Niewienda, A., Ludwig, D., Decker, J., Kaspar-Schoenefeld, S., Lilley, K. S., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-31492-0 · Cited by 441
Bekker-Jensen, D. B., Martínez-Val, A., Steigerwald, S., Rüther, P., Fort, K. L., Arrey, T. N., Harder, A., Makarov, A., & Olsen, J. V. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.tir119.001906 · Cited by 425
Self-citationRobust, reproducible and quantitative analysis of thousands of proteomes by micro-flow LC–MS/MS
Bian, Y., Zheng, R., Bayer, F. P., Wong, C., Chang, Y.-C., Meng, C., Zolg, D. P., Reinecke, M., Zecha, J., Wiechmann, S., et al. (2020) · Nature Communications · doi:10.1038/s41467-019-13973-x · Cited by 345
A blood atlas of COVID-19 defines hallmarks of disease severity and specificity
Ahern, D. J., Ai, Z., Ainsworth, M., Allan, C., Allcock, A., Angus, B., Ansari, M. A., Arancibia-Cárcamo, C. V., Aschenbrenner, D., Attar, M., et al. (2022) · Cell · doi:10.1016/j.cell.2022.01.012 · Cited by 328
Mass-spectrometry-based proteomics: from single cells to clinical applications
Guo, T., Steen, J. A., & Mann, M. (2025) · Nature · doi:10.1038/s41586-025-08584-0 · Cited by 320
Self-citationNoninvasive proteomic biomarkers for alcohol-related liver disease
Niu, L., Thiele, M., Geyer, P. E., Rasmussen, D. N., Webel, H. E., Santos, A., Gupta, R., Meier, F., Strauss, M., Kjaergaard, M., et al. (2022) · Nature Medicine · doi:10.1038/s41591-022-01850-y · Cited by 309
Self-citationUltra-fast proteomics with Scanning SWATH
Messner, C. B., Demichev, V., Bloomfield, N., Yu, J. S. L., White, M., Kreidl, M., Egger, A.-S., Freiwald, A., Ivosev, G., Wasim, F., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-021-00860-4 · Cited by 308
Automated sample preparation with SP 3 for low‐input clinical proteomics
Müller, T., Kalxdorf, M., Longuespée, R., Kazdal, D. N., Stenzinger, A., & Krijgsveld, J. (2020) · Molecular Systems Biology · doi:10.15252/msb.20199111 · Cited by 295
Skowronek, P., Thielert, M., Voytik, E., Tanzer, M. C., Hansen, F. M., Willems, S., Karayel, O., Brunner, A.-D., Meier, F., & Mann, M. (2022) · Molecular & Cellular Proteomics · doi:10.1016/j.mcpro.2022.100279 · Cited by 281
Self-citationUnbiased spatial proteomics with single-cell resolution in tissues
Mund, A., Brunner, A.-D., & Mann, M. (2022) · Molecular Cell · doi:10.1016/j.molcel.2022.05.022 · Cited by 259
Self-citationIgnjatovic, V., Geyer, P. E., Palaniappan, K. K., Chaaban, J. E., Omenn, G. S., Baker, M. S., Deutsch, E. W., & Schwenk, J. M. (2019) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00503 · Cited by 229
Self-citationTrapped Ion Mobility Spectrometry and Parallel Accumulation–Serial Fragmentation in Proteomics
Meier, F., Park, M. A., & Mann, M. (2021) · Molecular & Cellular Proteomics · doi:10.1016/j.mcpro.2021.100138 · Cited by 183
Self-citationSpatial single-cell mass spectrometry defines zonation of the hepatocyte proteome
Rosenberger, F. A., Thielert, M., Strauss, M. T., Schweizer, L., Ammar, C., Mädler, S. C., Metousis, A., Skowronek, P., Wahle, M., Madden, K., et al. (2023) · Nature Methods · doi:10.1038/s41592-023-02007-6 · Cited by 176
Targeted and Untargeted Proteomics Approaches in Biomarker Development
Sobsey, C. A., Ibrahim, S., Richard, V. R., Gaspar, V., Mitsa, G., Lacasse, V., Zahedi, R. P., Batist, G., & Borchers, C. H. (2020) · PROTEOMICS · doi:10.1002/pmic.201900029 · Cited by 171
Kitata, R. B., Yang, J., & Chen, Y. (2023) · Mass Spectrometry Reviews · doi:10.1002/mas.21781 · Cited by 165
PPM1H phosphatase counteracts LRRK2 signaling by selectively dephosphorylating Rab proteins
Berndsen, K., Lis, P., Yeshaw, W. M., Wawro, P. S., Nirujogi, R. S., Wightman, M., Macartney, T., Dorward, M., Knebel, A., Tonelli, F., et al. (2019) · eLife · doi:10.7554/elife.50416 · Cited by 139
The social and structural architecture of the yeast protein interactome
Michaelis, A. C., Brunner, A.-D., Zwiebel, M., Meier, F., Strauss, M. T., Bludau, I., & Mann, M. (2023) · Nature · doi:10.1038/s41586-023-06739-5 · Cited by 119
“Miniaturization and standardization of the workflow in combination with an ultra-robust liquid chromatography system with minimal overhead time coupled to a sensitive trapped ion mobility mass spectrometer utilizing the PASEF scan mode 9,10 resulted in very high data completeness across pull-downs.”
MethodSelf-citationThe social architecture of an in-depth cellular protein interactome
Michaelis, A. C., Brunner, A.-D., Zwiebel, M., Meier, F., Strauss, M. T., Bludau, I., & Mann, M. (2021) · doi:10.1101/2021.10.24.465633 · Cited by 119
Self-citationSkowronek, P., Wallmann, G., Wahle, M., Willems, S., & Mann, M. (2025) · Nature Protocols · doi:10.1038/s41596-024-01104-w · Cited by 43
Self-citation(2022) · doi:10.7554/elife.75227 · Cited by 26
Nordbeck, A. J., Martá‐Ariza, M., Ek Olofsson, H., Kanshin, E., Ueberheide, B., Jones, K., Sanford, B., Hamlett, E. D., Head, E., Mufson, E. J., et al. (2026) · Alzheimer's & Dementia · doi:10.1002/alz.71776
Metadata
- Authors
- Bache, N., Geyer, P. E., Bekker-Jensen, D. B., Hoerning, O., Falkenby, L., Treit, P. V., Doll, S., Paron, I., Müller, J. B., Meier, F., Olsen, J. V., Vorm, O., & Mann, M.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 17
- Issue
- 11
- Pages
- 2284-2296
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2951021236
- Cited by
- 411
- References
- 34
- FWCI
- 11.31
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.