Estimation of body composition from bioelectrical impedance of body segments: Comparison with dual-energy X-ray absorptiometry
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In twenty-eight healthy subjects, ten men and eighteen women, with a range in body mass index (BMI) of 17.9–31.6 kg/m 2 and an age range 20–60 years, body composition was estimated by dual-energy X-ray absorptiometry (DEXA), skinfold anthropometry (SFA) and bioelectrical impedance analysis (BIA) of the ‘whole body’and body segments. In thirteen subjects muscle mass was also estimated by 24 h urinary creatinine excretion. The relationship between fat-free mass (FFM) determined by DEXA and the impedance index of each body segment (calculated as Iength 2/impedance (Z)) was analysed. The strongest correlation was between FFM (DEXA) and height 2/‘whole-body’Z (Zw) (r 0.97 for the combined sexes, standard error of estimate (SEE) 2.72 kg). Separate prediction equations were found to be necessary for males and females when estimating FFM from BIA measurement of the arm (for men, r 0.93, SEE 1.98 kg; for women, r 0.75, SEE 2.87 kg). Muscle mass derived from 24 h creatinine excretion showed weak correlation with FFM (DEXA) (r 0.57, P = 0.03) and no correlation with FFM (SFA). FFM (SFA) correlated well with both FFM (DEXA) (r 0.96, SEE = 3.12 kg) and with height 2/Z w (r 0.92, SEE 4.52 kg). Measurement of the impedance of the arm offers a simple method of assessing the composition of the whole body in normal individuals, and it appears comparable with other methods of assessment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370
Segal, K., Burastero, S., Chun, A., Coronel, P., Pierson, R., & Wang, J. (1991) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/54.1.26 · Cited by 311
Estimation of body composition from bioelectric impedance of body segments
Baumgartner, R. N., Chumlea, W. C., & Roche, A. F. (1989) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/50.2.221 · Cited by 201
Measurements of total body and extracellular water in cirrhotic patients with and without ascites
McCullough, A. J., Mullen, K. D., & Kalhan, S. C. (1991) · Hepatology · doi:10.1002/hep.1840140626 · Cited by 135
Cited by
Sun, G., French, C. R., Martin, G. R., Younghusband, B., Green, R. C., Xie, Y.-G., Mathews, M., Barron, J. R., Fitzpatrick, D. G., Gulliver, W., et al. (2005) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/81.1.74 · Cited by 377
Achamrah, N., Colange, G., Delay, J., Rimbert, A., Folope, V., Petit, A., Grigioni, S., Déchelotte, P., & Coëffier, M. (2018) · PLoS ONE · doi:10.1371/journal.pone.0200465 · Cited by 337
Body Size and Hip Fracture Risk in Older Women
Ensrud, K. E., Lipschutz, R. C., Cauley, J. A., Seeley, D., Nevitt, M. C., Scott, J., Orwoll, E. S., Genant, H. K., & Cummings, S. R. (1997) · The American Journal of Medicine · doi:10.1016/s0002-9343(97)00025-9 · Cited by 214
Bioelectrical impedance underestimates total and truncal fatness in abdominally obese women
Neovius, M., Hemmingsson, E., Freyschuss, B., & Uddén, J. (2006) · Obesity · doi:10.1038/oby.2006.199 · Cited by 119
Hamdy, O., Mottalib, A., Morsi, A., El-Sayed, N., Goebel-Fabbri, A., Arathuzik, G., Shahar, J., Kirpitch, A., & Zrebiec, J. (2017) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2016-000259 · Cited by 87
Metadata
- Authors
- Stewart, S. P., Bramley, P. N., Heighton, R., Green, J. H., Horsman, A., Losowsky, M. S., & Smith, M. A.
- Venue
- British Journal of Nutrition
- Publisher
- Cambridge University Press (CUP)
- Published
- 1993-05
- Volume
- 69
- Issue
- 3
- Pages
- 645-655
- ISSN
- 0007-1145 (ISSN-L)
- 1475-2662
- OpenAlex
- W2136428689
- Cited by
- 98
- References
- 5
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.