Estimation of extracellular and total body water by multiple-frequency bioelectrical-impedance measurement

Segal, KR, Burastero, S, Chun, A, Coronel, P, Pierson, RN, Wang, J·1991·The American Journal of Clinical Nutrition

Abstract

This study evaluated a new technology of bioelectrical-impedance (BI) measurement that makes use of multiple frequencies (5, 50, and 100 kHz) for estimation of extracellular and total body water. In 36 healthy males, resistance and reactance at three frequencies were compared with extra-cellular water (ECW) and total body water (TBW) determined by isotope dilution. ECW was best predicted by resistance measured at 5 kHz, corrected for height and weight (R = 0.930, SEE = 1.94 L) whereas TBW was best predicted by resistance at 100 kHZ and weight (R = 0.947, SEE = 2.64 L). Cross-validation analysis on two randomly selected subsets (n = 18 each) indicated that the prediction equations were reproducible and valid. Thus, BI at dual frequencies is valid for determination of body-water compartments and may be useful in the nutritional assessment of patients in whom body water and hydration is of clinical concern.

Integrity signals

Registry

Crossref · 10.1093/ajcn/54.1.26

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The study tested its equations against earlier published BIA equations whose development samples Dioum et al. assumed included at least some black participants.

    “Performance of developed equations for the prediction of FFM was also tested using all available data (n=362) against previously published equations derived using participant samples which were assumed by Dioum et al. to consist of at least some ethnically black participants (5, 24–32).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Segal, K., Burastero, S., Chun, A., Coronel, P., Pierson, R., & Wang, J.
Affiliations
Mount Sinai Health System (US)
Corresponding author
Segal, KR
ORCID
Wang, J
Venue
The American Journal of Clinical Nutrition
Publisher
Elsevier BV
Published
1991-07
Volume
54
Issue
1
Pages
26-29
ISSN
0002-9165 (ISSN-L)
OpenAlex
W2153250908
Cited by
311
References
15
Citations by year
2026: 2 · 2025: 2 · 2024: 6 · 2023: 6 · 2022: 4 · 2021: 6 · 2020: 5 · 2019: 9 · 2018: 8 · 2017: 12 · 2016: 5 · 2015: 11 · 2014: 10 · 2013: 8 · 2012: 5
FWCI
7.46
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Clinical Nutrition (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Diabetes and Digestive and Kidney Diseases (DK-37352, DK37948, R01DK037352, R01DK037948)
Topics
  • Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
bioimpedance, extracellular water, total body water, body water compartments, hydration assessment, nutritional assessment
MeSH terms
Adult, Body Water, Electric Conductivity, Extracellular Space, Humans, Male, Middle Aged, Radioisotope Dilution Technique, Regression Analysis, Reproducibility of Results, Nutrition Assessment

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review