The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Bioelectrical impedance phase angle as a prognostic indicator in advanced pancreatic cancer
Open accessAbstract
Bioelectrical impedance analysis (BIA) is an easy-to-use, non-invasive and reproducible technique to evaluate changes in body composition and nutritional status. Phase angle, determined by BIA, has been found to be a prognostic indicator in several chronic conditions, such as HIV, liver cirrhosis, chronic obstructive pulmonary disease and lung cancer, and in patients undergoing dialysis. The present study investigated the prognostic role of phase angle in advanced pancreatic cancer. We evaluated a case series of fifty-eight stage IV pancreatic cancer patients treated at Cancer Treatment Centers of America®at Midwestern Regional Medical Center (Zion, IL, USA) between January 2000 and July 2003. BIA was conducted on all patients using a bioelectrical impedance analyser that operated at 50kHz. The phase angle was calculated as capacitance (Xc)/resistance (R) and expressed in degrees. The Kaplan–Meier method was used to calculate survival. Cox proportional hazard models were constructed to evaluate the prognostic effect of phase angle independent of other clinical and nutritional variables. The correlations between phase angle and traditional nutritional measures were evaluated using Pearson and Spearman coefficients. Patients with phase angle <5·0° had a median survival time of 6·3 (95% CI 3·5, 9·2) months (n 29), while those with phase angle >5·0° had a median survival time of 10·2 (95% CI 9·6, 10·8) months (n 29); this difference was statistically significant (P=0·02). The present study demonstrates that phase angle is a strong prognostic indicator in advanced pancreatic cancer. Similar studies in other cancer settings with larger sample sizes are needed to further validate the prognostic significance of the phase angle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For example, bioelectrical impedance analysis, which determines tissue electrical properties, has shown promise as a prognostic indicator to monitor cancer progression (Gupta et al., 2004a,b);”
From Membrane potential and cancer progression (2013) · cites this paper as Gupta et al., 2004b
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Bauer, J., Capra, S., & Ferguson, M. (2002) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601412 · Cited by 1,178 · cited 1×
“Some of the objective measures such as serum albumin are likely to be influenced by many nonnutritional factors (Bauer et al. 2002; Carney & Meguid, 2002; Waitzberg & Correia, 2003).”
Background(1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.524s · Cited by 549
Bioelectric impedance phase angle and body composition
Baumgartner, R., Chumlea, W., & Roche, A. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/48.1.16 · Cited by 477
Selberg, O., & Selberg, D. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-001-0570-4 · Cited by 476
Whole-body impedance–what does it measure?
Foster, K., & Lukaski, H. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.388s · Cited by 429
Detsky, A. S., Baker, J. P., Mendelson, R. A., Wolman, S. L., Wesson, D. E., & Jeejeebhoy, K. N. (1984) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607184008002153 · Cited by 412
Schwenk, A., Beisenherz, A., Römer, K., Kremer, G., Salzberger, B., & Elia, M. (2000) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/72.2.496 · Cited by 303
Nutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients.
Chertow, G. M., Lowrie, E. G., Wilmore, D. W., Gonzalez, J., Lew, N. L., Ling, J., Leboff, M. S., Gottlieb, M. N., Huang, W., & Zebrowski, B. (1995) · Journal of the American Society of Nephrology · doi:10.1681/asn.v6175 · Cited by 257
Ott, M., Fischer, H., Polat, H., Helm, E. B., Frenz, M., Caspary, W. F., & Lembcke, B. (1995) · Journal of Acquired Immune Deficiency Syndromes & Human Retrovirology · doi:10.1097/00042560-199505010-00003 · Cited by 240
Dittmar, M. (2003) · American Journal of Physical Anthropology · doi:10.1002/ajpa.10301 · Cited by 230
Nutritional and prognostic correlates of bioimpedance indexes in hemodialysis patients
Maggiore, Q., Nigrelli, S., Ciccarelli, C., Grimaldi, C., Rossi, G. A., & Michelassi, C. (1996) · Kidney International · doi:10.1038/ki.1996.535 · Cited by 222
Validation of bioelectrical-impedance measurements as a method to estimate body-water compartments
van Marken Lichtenbelt, W., Westerterp, K., Wouters, L., & Luijendijk, S. (1994) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/60.2.159 · Cited by 219
Toso, S., Piccoli, A., Gusella, M., Menon, D., Bononi, A., Crepaldi, G., & Ferrazzi, E. (2000) · Nutrition · doi:10.1016/s0899-9007(99)00230-0 · Cited by 218
Can Bioelectrical Impedance Analysis Identify Malnutrition in Preoperative Nutrition Assessment?
Barbosa-Silva, M. C. G., Barros, A. J. D., Post, C. L. A., Waitzberg, D. L., & Heymsfield, S. B. (2003) · Nutrition · doi:10.1016/s0899-9007(02)00932-2 · Cited by 162
Mushnick, R., Fein, P. A., Mittman, N., Goel, N. K., Chattopadhyay, J. P., & Avram, M. M. (2003) · Kidney International · doi:10.1046/j.1523-1755.64.s87.22.x · Cited by 155
Bioimpedance norms for the hemodialysis population
Chertow, G. M., Lazarus, J. M., Lew, N. L., Ma, L., & Lowrie, E. G. (1997) · Kidney International · doi:10.1038/ki.1997.493 · Cited by 155
The validity of bioelectrical impedance phase angle for nutritional assessment in children
Nagano, M., Suita, S., & Yamanouchi, T. (2000) · Journal of Pediatric Surgery · doi:10.1053/jpsu.2000.7766 · Cited by 134
Faisy, C., Rabbat, A., Kouchakji, B., & Laaban, J. P. (2000) · Intensive Care Medicine · doi:10.1007/s001340051198 · Cited by 120
Validation of bioelectrical impedance analysis in patients with amyotrophic lateral sclerosis
Desport, J., Preux, P., Bouteloup‐Demange, C., Clavelou, P., Beaufrère, B., Bonnet, C., & Couratier, P. (2003) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/77.5.1179 · Cited by 102
Use of bioelectrical impedance analysis measurements in the clinical management of malnutrition
Pencharz, P. B., & Azcue, M. (1996) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.485s · Cited by 101
Simons, J., Schols, A. M. W. J., Westerterp, K. R., ten Velde, G. P. M., & Wouters, E. F. �. (1995) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/61.4.741 · Cited by 100
Nutritional assessment in the hospitalized patient
Waitzberg, D. L., & Correia, M. I. T. D. (2003) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/00075197-200309000-00006 · Cited by 97
Requirements for Clinical Use of Bioelectrical Impedance Analysis (BIA)a
Lukaski, H. C. (1999) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1999.tb09451.x · Cited by 88
Fein, P. A., Gundumalla, G., Jorden, A., Matza, B., Chattopadhyay, J. P., & Avram, M. M. (2002) · PubMed · Cited by 85
Assessment of nutritional status and fluid deficits in advanced cancer
Sarhill, N., Mahmoud, F. A., Christie, R., & Tahir, A. (2003) · American Journal of Hospice and Palliative Medicine® · doi:10.1177/104990910302000610 · Cited by 75
Bioelectrical Impedance in Clinical Practice
Zarowitz, B. J. M., & Pilla, A. M. (1989) · DICP · doi:10.1177/1060028089023007-803 · Cited by 69
Fat‐Free Mass Qualitative Assessment with Bioelectric Impedance Analysis (BIA)
Talluri, T., LIETDKE, R. J., Evangelisti, A., Talluri, J., & Maggia, G. (1999) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1999.tb09454.x · Cited by 66
Estimation of body composition by bioelectrical impedance in cancer patients.
Fredrix, E. W. H. M., Saris, W. H. M., Soeters, P. B., Wouters, E. F. �., Kester, A. D. M., MEYENFELDT, M. F. V., & Westerterp, K. R. (1990) · PubMed · Cited by 66
Bioelectrical impedance analysis predicts outcome in patients with suspected bacteremia
Schwenk, A., Ward, L. C., Elia, M., & Scott, G. M. (1998) · Infection · doi:10.1007/bf02962247 · Cited by 60
Current Concepts in Nutritional Assessment
Carney, D. E., & Meguid, M. M. (2002) · Archives of Surgery · doi:10.1001/archsurg.137.1.42 · Cited by 58
Bioelectrical Impedance Analysis in Dialysis Patients
Pupim, L. B., Kent, P., & Ikizler, T. A. (1999) · Mineral and Electrolyte Metabolism · doi:10.1159/000057482 · Cited by 52
Use of Bioelectrical Impedance Analysis to Measure Total Body Water in Patients with Cystic Fibrosis
Azcue, M., Fried, M. D., & Pencharz, P. B. (1993) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1002/j.1536-4801.1993.tb10893.x · Cited by 37
Lima, C. M. S. R., & Centeno, B. A. (2002) · Current Opinion in Oncology · doi:10.1097/00001622-200207000-00010 · Cited by 34
Elia, M. (1993) · PubMed · Cited by 18
Adami, G., Marinari, G. M., Gandolfo, P., Cocchi, F., Friedman, D., & Scopinaro, N. (1993) · Surgery Today · doi:10.1007/bf00311363 · Cited by 16
[Importance of nutritional management for the treatment of carcinoma of the pancreas].
Higashiguchi, T., Kita, T., Noguchi, T., Kawarada, Y., & Mizumoto, R. (1988) · PubMed · Cited by 3
Cited by
Prognostic impact of disease-related malnutrition
Norman, K., Pichard, C., Lochs, H., & Pirlich, M. (2008) · Clinical Nutrition · doi:10.1016/j.clnu.2007.10.007 · Cited by 1,507
Norman, K., Stobäus, N., Pirlich, M., & Bosy-Westphal, A. (2012) · Clinical Nutrition · doi:10.1016/j.clnu.2012.05.008 · Cited by 1,049
Membrane potential and cancer progression
Yang, M., & Brackenbury, W. J. (2013) · Frontiers in Physiology · doi:10.3389/fphys.2013.00185 · Cited by 614
Bosy‐Westphal, A., Danielzik, S., Dörhöfer, R., Later, W., Wiese, S., & Müller, M. J. (2006) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607106030004309 · Cited by 595
Barbosa-Silva, M. C. G., & Barros, A. J. (2005) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/01.mco.0000165011.69943.39 · Cited by 400
Metadata
- Authors
- Gupta, D., Lis, C. G., Dahlk, S. L., Vashi, P. G., Grutsch, J. F., & Lammersfeld, C. A.
- Venue
- British Journal of Nutrition
- Publisher
- Cambridge University Press (CUP)
- Published
- 2004-12
- Volume
- 92
- Issue
- 6
- Pages
- 957-962
- ISSN
- 0007-1145 (ISSN-L)
- 1475-2662
- OpenAlex
- W2054232365
- Cited by
- 257
- References
- 37
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.