Coherent methods in the X-ray sciences
Open accessThe DOI matches its Crossref record; 192 of the 192 references it cites were found in a registry or an index.
Abstract
X-ray sources are developing rapidly and their coherent output is growing correspondingly. The increased coherent flux from modern X-ray sources is being matched with an associated development in experimental methods. This article reviews the literature describing the ideas that utilize the increased brilliance from modern X-ray sources. It explores how ideas in coherent X-ray science are leading to developments in other areas, and vice versa. The article describes measurements of coherence properties and uses this discussion as a base from which to describe partially coherent diffraction and X-ray phase-contrast imaging, with applications in materials science, engineering and medicine. Coherent diffraction imaging methods are reviewed along with associated experiments in materials science. Proposals for experiments to be performed with the new X-ray free-electron lasers are briefly discussed. The literature on X-ray photon-correlation spectroscopy is described and the features it has in common with other coherent X-ray methods are identified. Many of the ideas used in the coherent X-ray literature have their origins in the optical and electron communities and these connections are explored. A review of the areas in which ideas from coherent X-ray methods are contributing to methods for the neutron, electron and optical communities is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
On the Quantum Correction For Thermodynamic Equilibrium
Wigner, E. (1932) · Physical Review · doi:10.1103/physrev.40.749 · Cited by 9,283 · cited 1×
“ent illumination. 2.5 The Wigner Function A number of studies of coherence effects in X-ray physics, and other aspects of science touched on in this review, have been based around the Wigner function [18]. An appreciation of much of the literature benefits from an understanding of this powerful theoretical tool. The p…”
BackgroundInfluentialOptical Coherence and Quantum Optics
Mandel, L., & Wolf, E. (1995) · doi:10.1017/cbo9781139644105 · Cited by 8,356
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596
GABOR, D. (1948) · Nature · doi:10.1038/161777a0 · Cited by 4,548
A practical algorithm for the determination of phase from image and diffraction plane pictures
Gerchberg, R. W. (1972) · Optik · Cited by 4,519
Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry
Takeda, M., Ina, H., & Kobayashi, S. (1982) · Journal of the Optical Society of America · doi:10.1364/josa.72.000156 · Cited by 4,277
Correlation between Photons in two Coherent Beams of Light
BROWN, R. H., & TWISS, R. Q. (1956) · Nature · doi:10.1038/177027a0 · Cited by 2,573
Nye, J. F., & Berry, M. V. (1974) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1974.0012 · Cited by 2,157
Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object
Paganin, D., Mayo, S. C., Gureyev, T. E., Miller, P. R., & Wilkins, S. W. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01010.x · Cited by 2,062
Cited by
Wildenschild, D., & Sheppard, A. P. (2013) · Advances in Water Resources · doi:10.1016/j.advwatres.2012.07.018 · Cited by 1,239
Phase Retrieval with Application to Optical Imaging: A contemporary overview
Shechtman, Y., Eldar, Y. C., Cohen, O., Chapman, H. N., Miao, J., & Segev, M. (2015) · IEEE Signal Processing Magazine · doi:10.1109/msp.2014.2352673 · Cited by 1,131
Ptychographic X-ray computed tomography at the nanoscale
Dierolf, M., Menzel, A., Thibault, P., Schneider, P., Kewish, C. M., Wepf, R., Bunk, O., & Pfeiffer, F. (2010) · Nature · doi:10.1038/nature09419 · Cited by 926
X-Rays and Extreme Ultraviolet Radiation: Principles and Applications
Attwood, D., & Sakdinawat, A. (2016) · CERN Document Server (European Organization for Nuclear Research) · doi:10.1017/cbo9781107477629 · Cited by 644
Lin, F., Liu, Y., Yu, X., Cheng, L., Singer, A., Shpyrko, O. G., Xin, H. L., Tamura, N., Tian, C., Weng, T.-C., et al. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00007 · Cited by 582
Transport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Imaging without lenses: achievements and remaining challenges of wide-field on-chip microscopy
Greenbaum, A., Luo, W., Su, T.-W., Göröcs, Z., Xue, L., Isikman, S. O., Coskun, A. F., Mudanyali, O., & Ozcan, A. (2012) · Nature Methods · doi:10.1038/nmeth.2114 · Cited by 540
Bultreys, T., De Boever, W., & Cnudde, V. (2016) · Earth-Science Reviews · doi:10.1016/j.earscirev.2016.02.001 · Cited by 474
Maximum-likelihood refinement for coherent diffractive imaging
Thibault, P., & Guizar-Sicairos, M. (2012) · New Journal of Physics · doi:10.1088/1367-2630/14/6/063004 · Cited by 416
Phase retrieval in X-ray phase-contrast imaging suitable for tomography
Burvall, A., Lundström, U., Takman, P. A. C., Larsson, D. H., & Hertz, H. M. (2011) · Optics Express · doi:10.1364/oe.19.010359 · Cited by 263
Attosecond Extreme Ultraviolet Vortices from High-Order Harmonic Generation
Hernández-García, C., Picón, A., San Román, J., & Plaja, L. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.083602 · Cited by 258
High-resolution three-dimensional partially coherent diffraction imaging
Clark, J. N., Huang, X., Harder, R., & Robinson, I. K. (2012) · Nature Communications · doi:10.1038/ncomms1994 · Cited by 232
Mukamel, S., Healion, D., Zhang, Y., & Biggs, J. D. (2013) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040412-110021 · Cited by 200
“, 1012 photons in 85 as at a frequency of 8 keV (15), can generate sequences of pulses suitable for coherent spectroscopy applications (16).”
BackgroundMolecular Imaging Using X-Ray Free-Electron Lasers
Barty, A., Küpper, J., & Chapman, H. N. (2013) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-032511-143708 · Cited by 194
Vila-Comamala, J., Diaz, A., Guizar-Sicairos, M., Mantion, A., Kewish, C. M., Menzel, A., Bunk, O., & David, C. (2011) · Optics Express · doi:10.1364/oe.19.021333 · Cited by 191
High-pressure studies with x-rays using diamond anvil cells
Shen, G., & Mao, H. K. (2017) · Reports on Progress in Physics · doi:10.1088/1361-6633/80/1/016101 · Cited by 184
Nanoscale Hard X-Ray Microscopy Methods for Materials Studies
Holt, M., Harder, R., Winarski, R., & Rose, V. (2013) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-071312-121654 · Cited by 183
Lensless imaging using broadband X-ray sources
Abbey, B., Whitehead, L. W., Quiney, H. M., Vine, D. J., Cadenazzi, G. A., Henderson, C. A., Nugent, K. A., Balaur, E., Putkunz, C. T., Peele, A. G., et al. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.125 · Cited by 178
“(4) The diffraction patterns from each sampled wavelength are calculated via interpolation onto the new set of points defined by the rescaled values for rj.”
BackgroundMethodSelf-citationCatecholaminergic Polymorphic Ventricular Tachycardia
Leenhardt, A., Denjoy, I., & Guicheney, P. (2012) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.111.962027 · Cited by 173
Coherent X-Ray Diffraction Imaging
Miao, J., Sandberg, R. L., & Song, C. (2012) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2011.2157306 · Cited by 172
Transmission and emission x-ray microscopy: operation modes, contrast mechanisms and applications
Kaulich, B., Thibault, P., Gianoncelli, A., & Kiskinova, M. (2011) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/23/8/083002 · Cited by 169
Adverse Effects of Doxorubicin and Its Metabolic Product on Cardiac RyR2 and SERCA2A
Hanna, A. D., Lam, A., Tham, S., Dulhunty, A. F., & Beard, N. A. (2014) · Molecular Pharmacology · doi:10.1124/mol.114.093849 · Cited by 163
Advantages of phase retrieval for fast x-ray tomographic microscopy
Mokso, R., Marone, F., Irvine, S., Nyvlt, M., Schwyn, D., Mader, K., Taylor, G. K., Krapp, H. G., Skeren, M., & Stampanoni, M. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/49/494004 · Cited by 56
Metadata
- Authors
- Nugent, K. A.
- Venue
- Advances in Physics
- Publisher
- Informa UK Limited
- Published
- 2010-01
- Volume
- 59
- Issue
- 1
- Pages
- 1-99
- ISSN
- 0001-8732 (ISSN-L)
- 1460-6976
- OpenAlex
- W2014844812
- Cited by
- 476
- References
- 192
- FWCI
- 30.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.